Junctional Rhythms After Transcatheter Aortic Valve Implantation: Incidence, Temporal Patterns, and Clinical Outcomes
Abstract
BACKGROUND Conduction disturbances are common after transcatheter aortic valve implantation (TAVI), yet the clinical implications of junctional rhythm (JR) remain poorly characterized. We aimed to assess the incidence, temporal characteristics, and clinical outcomes associated with JR occurring after TAVI. METHODS We conducted a prospective study including all TAVI patients at Clermont-Ferrand University Hospital between December 2023 and April 2025. Patients who developed JR were identified, and a propensity score was used to match them in a 1:3 ratio with patients without JR. RESULTS Among 616 TAVI procedures, JR was identified in 26 patients (4.2%). The mean time to onset was 41±22 hours after TAVI, with a mean junctional rate of 71±12 bpm. At baseline, there were no significant differences in clinical, electrocardiographic, or procedural characteristics between patients with and without JR. The incidence of in-hospital high-grade AV block did not differ significantly between groups (11.5% vs 10.3%, p=0.48). Permanent pacemaker implantation occurred in 38.5% (10/26) of JR patients vs 16.7% (13/78) of controls (p = 0.02). JR was consistently asymptomatic and transient, and its morphology suggested either Hisian or infra-Hisian origin. CONCLUSION JR after TAVI appeared to be an infrequent and transient phenomenon. Although pacemaker implantation was more frequent among JR patients, no excess of documented high-grade atrioventricular block was observed. The higher pacemaker rate appeared primarily related to precautionary management decisions. These findings require confirmation in larger multicenter cohorts.
Related
- Incidence and timing of new-onset atrial fibrillation after transcatheter aortic valve implantation: 14-day electrocardiographic monitoring
- Incidence and Predictors of Complications After Transcatheter Aortic Valve Implantation According to VARC‐3 Criteria: A Systematic Review and Meta‐Analysis
- Temporal trends in patients undergoing artificial urinary sphincter implantation: explantation outcomes and early failure patterns in a tertiary reconstructive referral center
- Landmark-based low implantation using a balloon-expandable valve to avoid sinus sequestration during redo transcatheter aortic valve implantation: a case report
- Modified balloon-assisted shoehorn technique for transcatheter aortic valve implantation in functionally horizontal anatomy: a case report
BibTeX
@article{massoullie2026junctional,
title = {{Junctional Rhythms After Transcatheter Aortic Valve Implantation: Incidence, Temporal Patterns, and Clinical Outcomes}},
author = {Grégoire Massoullié and Margot Kachkach and Samuel Adelou and Antoine Boudias and Frederic Jean and Pierre-Antoine Catalan and Saer Abu-Alrub and Nicolas Combaret and Bruno Pereira and Géraud Souteyrand and Romain Eschalier},
journal = {Canadian Journal of Cardiology (CJC) : official journal of the Canadian Cardiovascular Society (CCS)},
year = {2026},
month = nov,
doi = {10.1016/j.cjco.2026.03.005},
url = {https://hal.science/hal-05864232v1},
note = {CC BY},
}
RIS
TY - JOUR
TI - Junctional Rhythms After Transcatheter Aortic Valve Implantation: Incidence, Temporal Patterns, and Clinical Outcomes
AU - Grégoire Massoullié
AU - Margot Kachkach
AU - Samuel Adelou
AU - Antoine Boudias
AU - Frederic Jean
AU - Pierre-Antoine Catalan
AU - Saer Abu-Alrub
AU - Nicolas Combaret
AU - Bruno Pereira
AU - Géraud Souteyrand
AU - Romain Eschalier
PY - 2026
DA - 2026/11/13
JO - Canadian Journal of Cardiology (CJC) : official journal of the Canadian Cardiovascular Society (CCS)
DO - 10.1016/j.cjco.2026.03.005
UR - https://hal.science/hal-05864232v1
AB - BACKGROUND Conduction disturbances are common after transcatheter aortic valve implantation (TAVI), yet the clinical implications of junctional rhythm (JR) remain poorly characterized. We aimed to assess the incidence, temporal characteristics, and clinical outcomes associated with JR occurring after TAVI. METHODS We conducted a prospective study including all TAVI patients at Clermont-Ferrand University Hospital between December 2023 and April 2025. Patients who developed JR were identified, and a propensity score was used to match them in a 1:3 ratio with patients without JR. RESULTS Among 616 TAVI procedures, JR was identified in 26 patients (4.2%). The mean time to onset was 41±22 hours after TAVI, with a mean junctional rate of 71±12 bpm. At baseline, there were no significant differences in clinical, electrocardiographic, or procedural characteristics between patients with and without JR. The incidence of in-hospital high-grade AV block did not differ significantly between groups (11.5% vs 10.3%, p=0.48). Permanent pacemaker implantation occurred in 38.5% (10/26) of JR patients vs 16.7% (13/78) of controls (p = 0.02). JR was consistently asymptomatic and transient, and its morphology suggested either Hisian or infra-Hisian origin. CONCLUSION JR after TAVI appeared to be an infrequent and transient phenomenon. Although pacemaker implantation was more frequent among JR patients, no excess of documented high-grade atrioventricular block was observed. The higher pacemaker rate appeared primarily related to precautionary management decisions. These findings require confirmation in larger multicenter cohorts.
SN - 2589-790X
ER -