Incidence and Predictors of Complications After Transcatheter Aortic Valve Implantation According to VARC‐3 Criteria: A Systematic Review and Meta‐Analysis
39 affiliations
- 1Division of Cardiology, Cardiovascular and Thoracic Department Città della Salute e della Scienza Turin Italy
- 2Division of Cardiology, Department of Medical Sciences University of Turin Italy
- 3Royal Brompton and Harefield Hospitals Trust and Imperial College London UK
- 4Cardiology Clinic, Department of Cardiac, Thoracic, and Vascular Sciences and Public Health Padova University of Padua Italy
- 5Division of Cardiac Surgery, Cardiovascular and Thoracic Department Città della Salute e della Scienza Turin Italy
- 6Department of Cardiology Kerckhoff Heart and Thorax Center Bad Nauheim Germany
- 7Interventional Cardiology Unit, Cardiovascular Department Fondazione Poliambulanza Brescia Italy
- 8Department of internal medicine St. Johannes hospital Dortmund Dortmund Germany
- 9Department of cardiology University Oldenburg Oldenburg Germany
- 10Department of Cardiology, Pulmonology, and Vascular Medicine, University Hospital Düsseldorf Medical Faculty of the Heinrich Heine University Düsseldorf Düsseldorf Germany
- 11Cardiovascular Research Institute Düsseldorf (CARID) Düsseldorf Germany
- 12IRCCS Centro Cardiologico Monzino Valvular and Structural Invasive Cardiology Unit Milan Italy
- 13Medizinische Klinik und Poliklinik I LMU Klinikum München Munich Germany
- 14Division of Cardiac Surgery IRCCS Azienda Ospedaliero‐Universitaria di Bologna Italy
- 15Technical University of Munich, TUM School of Medicine and Health, Department of Cardiovascular Surgery TUM University Hospital German Heart Center Munich Germany
- 16Department of Cardiology, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences) Southern Medical University Guangzhou China
- 17Universitätsklinikum St. Pölten Karl Landsteiner Privatuniversität für Gesundheitswissenschaften Dunant‐Platz St. Pölten Austria
- 18Cardiovascular Research and Advanced Education, MedStar Heart and Vascular Institute MedStar Washington Hospital Center Washington DC USA
- 19Interventional Cardiology Unit, Sheba Medical Center, Ramat Gan Tel Aviv University Israel
- 20Division of Cardiology, Mount Sinai Medical Center Icahn School of Medicine at Mount Sinai New York NY USA
- 21Collegium Medicum ‐ Faculty of Medicine WSB University Dabrowa Gornicza Poland
- 22St. Paul’s Hospital University of British Columbia Vancouver Canada
- 23Department of Cardiology, Division of Minimal Invasive Treatment Center IMS Tokyo Katsushika General Hospital Katsushika City Tokyo Japan
- 24Morriston Regional Heart Centre Swansea University Medical School Swansea UK
- 25IRCCS Humanitas Research Hospital Rozzano, Milan Italy
- 26Cardiology Unit, Cardiothoracic and Vascular Department (DICATOV) IRCCS Ospedale Policlinico San Martino Genoa Italy
- 27TUM University Hospital German Heart Center Technical University of Munich Germany
- 28German Center for Cardiovascular Research (DZHK) Berlin Germany
- 29Heart Center Lucerne, Luzerner Kantonsspital Lucerne Switzerland
- 30Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine University of Cologne Cologne Germany
- 31National Taiwan University Hospital Taipei Taiwan
- 32Herzzentrum Dresden, University Clinic, Department of Internal Medicine and Cardiology Technische Universitaet Dresden Dresden Germany
- 33Quebec Heart & Lung Institute Laval University Quebec City Quebec Canada
- 34Department of Cardiology The Alfred Melbourne Australia
- 35Monash Alfred Baker Centre for Cardiovascular Research, School of Translational Medicine Monash University Melbourne Australia
- 36Heart Failure Research Group Baker Institute Melbourne Australia
- 37Department of Cardiology, School of Medicine University of Galway Ireland
- 38Department of Cardiology Clinique Saint Hilaire Rouen France
- 39Montefiore‐Einstein Center for Heart and Vascular Care, Montefiore Medical Center Albert Einstein College of Medicine Bronx NY USA
Abstract
Background: Despite continuous advancements in devices and techniques, transcatheter aortic valve implantation remains associated with complications impacting outcomes. In 2021, the Valve Academic Research Consortium (VARC) introduced the VARC‐3 criteria to better classify procedural complications.
Methods: We conducted a systematic review and meta‐analysis of studies reporting transcatheter aortic valve implantation‐related complications using VARC‐3 definitions between 2021 and 2025. The primary end point was all‐cause mortality at latest follow‐up. Secondary end points included major VARC‐3 complications and predictors of adverse events.
Results: A total of 57 studies with 73 588 patients were included. The cohort had a mean age of 81.7 years, 51.7% were women, and most had preserved ejection fraction (55.5%) and low‐to‐moderate surgical risk (Society of Thoracic Surgeons [STS] predicted risk of mortality [PROM] 4.1%). Technical and 30‐day device success rates were 95% and 90%, respectively; early safety rate at 30 days was 66%. At average 12 months follow‐up, all‐cause mortality was 10.2%. The most common complication was permanent pacemaker implantation (13%), followed by type 2 or greater bleeding (9.7%), acute kidney injury stage 3–4 (4.7%), major vascular events (4.3%), and stroke (3.0%). Moderate/severe paravalvular regurgitation and patient‐prosthesis mismatch occurred in 4% and 8%, respectively. Study‐level pooled predictor analyses showed that acute kidney injury, type 2 or greater bleeding, paravalvular regurgitation, non‐structural valve dysfunction, and higher STS score were associated with higher mortality, while eccentric/severe aortic valve calcification was associated with significant paravalvular regurgitation.
Conclusions: Transcatheter aortic valve implantation shows high procedural success but non‐negligible complication rates under VARC‐3 criteria. acute kidney injury, type 2 or greater bleeding, NSVD, periprocedural stroke and myocardial infarction after transcatheter aortic valve implantation were associated with higher mortality.
Related
- Incidence and timing of new-onset atrial fibrillation after transcatheter aortic valve implantation: 14-day electrocardiographic monitoring
- Junctional Rhythms After Transcatheter Aortic Valve Implantation: Incidence, Temporal Patterns, and Clinical Outcomes
- Predictors of All-Cause Mortality in Patients with Classical Low-Flow Low-Gradient Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation
- Coronary artery disease management in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation: a systematic review and meta-analysis of randomised controlled trials
- Incidence and predictors of peripheral intravenous cannula complications among pediatric patients in public hospitals of Gurage zone, Ethiopia: a multicenter prospective cohort study
BibTeX
@article{giacobbe2026incidence,
title = {{Incidence and Predictors of Complications After Transcatheter Aortic Valve Implantation According to VARC‐3 Criteria: A Systematic Review and Meta‐Analysis}},
author = {Federico Giacobbe and Francesco Bruno and Marco Brero and Pierre Meynet and Andrea Solano and Sergio Capoccia and Riccardo Pilia and Fabrizio D’Ascenzo and Federico Conrotto and Giuseppe Tarantini and Michele la Torre and Won‐Keun Kim and Andrea Buono and Johannes Blumenstein and Amin Polzin and Marco Gennari and Jonas M. D. Gmeiner and Antonio Piperata and Hendrik Ruge and Jie Li and Julia Mascherbauer and Ron Waksman and Israel Barbash and Gilbert Tang and Tomasz Gasior and John Webb and Hirofumi Hioki and Daniel Obaid and Antonio Mangieri and Gabriele Crimi and Michael Joner and Stefan Toggweiler and Victor Mauri and Mao‐Shin Lin and Stephan Haussig and Marisa Avvedimento and Shane Nanayakkara and Patrick W. Serruys and Quentin Landolff and Azeem Latib and Josep Rodes‐Cabau and Gaetano Maria De Ferrari and Ovidio de Filippo},
journal = {Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease},
year = {2026},
month = sep,
doi = {10.1161/jaha.125.045455},
url = {https://doi.org/10.1161/jaha.125.045455},
note = {CC BY-NC 4.0},
}
RIS
TY - JOUR
TI - Incidence and Predictors of Complications After Transcatheter Aortic Valve Implantation According to VARC‐3 Criteria: A Systematic Review and Meta‐Analysis
AU - Federico Giacobbe
AU - Francesco Bruno
AU - Marco Brero
AU - Pierre Meynet
AU - Andrea Solano
AU - Sergio Capoccia
AU - Riccardo Pilia
AU - Fabrizio D’Ascenzo
AU - Federico Conrotto
AU - Giuseppe Tarantini
AU - Michele la Torre
AU - Won‐Keun Kim
AU - Andrea Buono
AU - Johannes Blumenstein
AU - Amin Polzin
AU - Marco Gennari
AU - Jonas M. D. Gmeiner
AU - Antonio Piperata
AU - Hendrik Ruge
AU - Jie Li
AU - Julia Mascherbauer
AU - Ron Waksman
AU - Israel Barbash
AU - Gilbert Tang
AU - Tomasz Gasior
AU - John Webb
AU - Hirofumi Hioki
AU - Daniel Obaid
AU - Antonio Mangieri
AU - Gabriele Crimi
AU - Michael Joner
AU - Stefan Toggweiler
AU - Victor Mauri
AU - Mao‐Shin Lin
AU - Stephan Haussig
AU - Marisa Avvedimento
AU - Shane Nanayakkara
AU - Patrick W. Serruys
AU - Quentin Landolff
AU - Azeem Latib
AU - Josep Rodes‐Cabau
AU - Gaetano Maria De Ferrari
AU - Ovidio de Filippo
PY - 2026
DA - 2026/09/29
JO - Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease
DO - 10.1161/jaha.125.045455
UR - https://doi.org/10.1161/jaha.125.045455
AB - Background: Despite continuous advancements in devices and techniques, transcatheter aortic valve implantation remains associated with complications impacting outcomes. In 2021, the Valve Academic Research Consortium (VARC) introduced the VARC‐3 criteria to better classify procedural complications. Methods: We conducted a systematic review and meta‐analysis of studies reporting transcatheter aortic valve implantation‐related complications using VARC‐3 definitions between 2021 and 2025. The primary end point was all‐cause mortality at latest follow‐up. Secondary end points included major VARC‐3 complications and predictors of adverse events. Results: A total of 57 studies with 73 588 patients were included. The cohort had a mean age of 81.7 years, 51.7% were women, and most had preserved ejection fraction (55.5%) and low‐to‐moderate surgical risk (Society of Thoracic Surgeons [STS] predicted risk of mortality [PROM] 4.1%). Technical and 30‐day device success rates were 95% and 90%, respectively; early safety rate at 30 days was 66%. At average 12 months follow‐up, all‐cause mortality was 10.2%. The most common complication was permanent pacemaker implantation (13%), followed by type 2 or greater bleeding (9.7%), acute kidney injury stage 3–4 (4.7%), major vascular events (4.3%), and stroke (3.0%). Moderate/severe paravalvular regurgitation and patient‐prosthesis mismatch occurred in 4% and 8%, respectively. Study‐level pooled predictor analyses showed that acute kidney injury, type 2 or greater bleeding, paravalvular regurgitation, non‐structural valve dysfunction, and higher STS score were associated with higher mortality, while eccentric/severe aortic valve calcification was associated with significant paravalvular regurgitation. Conclusions: Transcatheter aortic valve implantation shows high procedural success but non‐negligible complication rates under VARC‐3 criteria. acute kidney injury, type 2 or greater bleeding, NSVD, periprocedural stroke and myocardial infarction after transcatheter aortic valve implantation were associated with higher mortality.
SN - 2047-9980
ER -