Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 54 min ago
Peer-reviewedCC BYDiscover Chemistry

Development and validation of an RP-HPLC method for the quantification of residual 7-chloroquinaldine impurity in alkene aldehyde intermediate of montelukast sodium

  1. 1Department of Chemical Sciences, School of Science, G. S. F. C. University
  2. 2Department of Chemistry, Faculty of Science, The Maharaja Sayajirao University of Baroda

Abstract

During the synthesis of montelukast sodium drug substance from the intermediate 3-(2-(7-chloroquinolin-2-yl)-(E)-vinyl)benzaldehyde (alkene aldehyde), the purity of this intermediate is a critical factor that directly influences the overall quality and yield of the final drug product. To ensure consistent drug synthesis, strict process controls, analytical monitoring, and purification techniques must be implemented at each stage of intermediate production. With this motivation herein, a robust analytical method was developed and validated for the quantification of 7-Chloroquinaldine (7-CQ) in alkene aldehyde (AAI) in accordance with the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) guidelines. By improving AAI purity, manufacturers can enhance drug quality, regulatory compliance, and overall production efficiency. HPLC analysis of AAI and related impurities to 7-CQ was performed using a Shimadzu LC 2010 binary system equipped with a UV detector at 230 nm and operated via LC solution software. Separation was achieved on an XBridge C18 column (150 × 4.6 mm, 5 μm) using a gradient mobile phase of 0.075% formic acid buffer and acetonitrile. Mobile phase A was prepared in a 1:1 ratio, while mobile phase B was prepared in a 1:9 ratio. Injection volume was 10 µL, and total run time was 35 min. The validated HPLC method for 7-CQ demonstrated linearity over the concentration range of 0.49–3.72 ppm with a correlation coefficient (r) of 0.9992 and a regression coefficient (R2) of 0.9983. The intercept and slope were 2415.09 ± 3348.29 and 61,762, respectively. The method exhibited high sensitivity with a limit of detection (LOD) of 0.0493 ppm and a limit of quantification (LOQ) of 0.4932 ppm. Precision was excellent, with a repeatability relative standard deviation %RSD of 0.04%, an intermediate precision % RSD of 4.57% and precision at LOQ of 5.76%. Accuracy was confirmed with recovery values ranging from 96.80% to 100% and % RSD values between 0.26% and 0.58%,demonstrating the method’s robustness, reproducibility, and suitability for routine quantitative analysis. These results confirm the reliability of the method for the routine analysis and detection of 7-CQ as an impurity in alkene aldehyde.

Related

  1. Simultaneous quantification of Minoxidil and Dexpanthenol in topical solutions: Development and validation of a RP-HPLC procedure
    Aya Sabouny, Ali Ibrahim, Saleh Trefi +1
    Bulletin of Pharmaceutical Sciences. Assiut UniversityPeer-reviewedCC BYFull textAnalytical chemistryDOAJ
  2. Analytical Method Development and Validation for the Quantification of Related Substances in Pantoprazole Gastro-Resistant Tablets by RP-HPLC: A Critical Review
    Abirami A, Prarthana J, Surya R +1
    International Journal of Research in Pharmaceutical SciencesPeer-reviewedCC BYFull textAnalytical chemistryDOAJ
  3. Development and validation of a novel candidate reference procedure for the quantification of 3-nitro-L-tyrosine, 3-monoiodo-L-tyrosine and 3,5-diiodo-L-tyrosine in urine by isotope dilution and LC-ESI-MS/MS
    Heli Potes-Rodriguez, Pablo Rodríguez-González, Juan Manuel Marchante-Gayon +6
    Microchemical JournalPeer-reviewedCC BY-NC-ND 4.0Full textAnalytical chemistryHAL
  4. Development of an LC–MS/MS Method for Simultaneous Quantification of Erythromycin A and Seven Metabolites: Initial Residue Profile in Salmon Muscle with Skin
    Molecules (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral chemistryEurope PMC
  5. Development and Bayesian Uncertainty Quantification of Transferable Coarse-Grained Models for Carbohydrates
    Parisa Farzeen, Soumil Y. Joshi, Abhishek T. Sose +1
    Journal of Chemical Theory and ComputationPeer-reviewedCC BY 4.0Full textPhysical chemistryPMC
BibTeX
@article{patel2026development,
  title = {{Development and validation of an RP-HPLC method for the quantification of residual 7-chloroquinaldine impurity in alkene aldehyde intermediate of montelukast sodium}},
  author = {Jigneshkumar N. Patel and Kirit Kumar Joshi and Prakash Samnani and Archana R. Deokar},
  journal = {Discover Chemistry},
  year = {2026},
  month = oct,
  doi = {10.1007/s44371-026-01028-2},
  url = {https://doi.org/10.1007/s44371-026-01028-2},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Development and validation of an RP-HPLC method for the quantification of residual 7-chloroquinaldine impurity in alkene aldehyde intermediate of montelukast sodium
AU  - Jigneshkumar N. Patel
AU  - Kirit Kumar Joshi
AU  - Prakash Samnani
AU  - Archana R. Deokar
PY  - 2026
DA  - 2026/10/25
JO  - Discover Chemistry
DO  - 10.1007/s44371-026-01028-2
UR  - https://doi.org/10.1007/s44371-026-01028-2
AB  - During the synthesis of montelukast sodium drug substance from the intermediate 3-(2-(7-chloroquinolin-2-yl)-(E)-vinyl)benzaldehyde (alkene aldehyde), the purity of this intermediate is a critical factor that directly influences the overall quality and yield of the final drug product. To ensure consistent drug synthesis, strict process controls, analytical monitoring, and purification techniques must be implemented at each stage of intermediate production. With this motivation herein, a robust analytical method was developed and validated for the quantification of 7-Chloroquinaldine (7-CQ) in alkene aldehyde (AAI) in accordance with the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) guidelines. By improving AAI purity, manufacturers can enhance drug quality, regulatory compliance, and overall production efficiency. HPLC analysis of AAI and related impurities to 7-CQ was performed using a Shimadzu LC 2010 binary system equipped with a UV detector at 230 nm and operated via LC solution software. Separation was achieved on an XBridge C18 column (150 × 4.6 mm, 5 μm) using a gradient mobile phase of 0.075% formic acid buffer and acetonitrile. Mobile phase A was prepared in a 1:1 ratio, while mobile phase B was prepared in a 1:9 ratio. Injection volume was 10 µL, and total run time was 35 min. The validated HPLC method for 7-CQ demonstrated linearity over the concentration range of 0.49–3.72 ppm with a correlation coefficient (r) of 0.9992 and a regression coefficient (R2) of 0.9983. The intercept and slope were 2415.09 ± 3348.29 and 61,762, respectively. The method exhibited high sensitivity with a limit of detection (LOD) of 0.0493 ppm and a limit of quantification (LOQ) of 0.4932 ppm. Precision was excellent, with a repeatability relative standard deviation %RSD of 0.04%, an intermediate precision % RSD of 4.57% and precision at LOQ of 5.76%. Accuracy was confirmed with recovery values ranging from 96.80% to 100% and % RSD values between 0.26% and 0.58%,demonstrating the method’s robustness, reproducibility, and suitability for routine quantitative analysis. These results confirm the reliability of the method for the routine analysis and detection of 7-CQ as an impurity in alkene aldehyde.
SN  - 3005-1193
ER  -