Cyclic Fouling and Flux Recovery in a Piezoelectrically Actuated Polytetrafluoroethylene Membrane Module.

  1. 1School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing 100083, China.
  2. 2Tianjin College, University of Science and Technology Beijing, Tianjin 301830, China.

Abstract

Membrane fouling limits pressure-driven filtration by increasing hydraulic resistance and cleaning demand. Here, an external lead zirconate titanate actuator (PZT) was coupled to a passive polytetrafluoroethylene (PTFE) microfiltration membrane to examine cyclic fouling and short-term flux recovery. The primary pressure series comprised chronological sodium-alginate filtration stages at 6-30 kPa using a nominal 5 μm membrane from two membrane histories; additional actuation-duration, dosing, imaging, and interfacial analyses were treated as separate evidence streams. Across 31 adjacent activation events, endpoint flux increased in 28 events and decreased in three, with a median change of 1351 L/m²h. These events were repeated observations within the two histories and did not constitute independent replicates or a matched sham control. Segment-wise Hermia fitting retained 39 decline windows, for which cake filtration gave the minimum Akaike information criterion (AIC) in 34 windows (87.2%); however, the selected model was recovered in fewer than 80% of bootstrap resamples for 15 windows, underscoring that the fits are empirical descriptors rather than unique mechanism identifiers. The measured real electrical input was about 1.5 W, whereas the estimated viscosity-related flux gain from the recorded temperature change was only 0.08-2.68%, indicating that bulk heating alone could not explain the observed recovery. Separate microscopy and extended Derjaguin-Landau-Verwey-Overbeek (XDLVO) analyses were consistent with removal or redistribution of surface deposits and altered post-treatment attachment propensity. Overall, the data establish a reproducible within-history temporal association between actuator operation and flux recovery, while the absence of a matched sham experiment precludes attribution to a single mechanical, hydraulic, electrical, or pressure-transient pathway.

Related

  1. Low-Cost Ceramic Membrane with Concentrated Pore Size Distribution for Flue Gas Moisture Recovery.
    Tao Li, Zheng Zhang, Tengfei Li +3
    MembranesPeer-reviewedCC BYFull textHydrology & soilsEurope PMC
  2. Genome-resolved metagenomics reveals potential biochemical capabilities of a microbial community in an industrial wastewater membrane bioreactor during performance deterioration and recovery
    Hana Barak, Asher Brenner, Ariel Kushmaro
    Frontiers in MicrobiologyPeer-reviewedCC BY 4.0Full textEnvironmental science & pollutionCrossrefEurope PMC
  3. Sustainable water recovery from steel industry wastewater via direct contact membrane distillation
    Hussein Fairousha Sulaiman, Imen Bousrih, Simón Díaz-Quezada +2
    Discover WaterPeer-reviewedCC BYFull textHydrology & soilsDOAJ
  4. Polytetrafluoroethylene utensils as a source of micro- and nanoplastics: Insights from a Drosophila model
    Mohamed Alaraby, Doaa Abass, Elham Farghal Elkady +4
    Eco-Environment & HealthPeer-reviewedCC BYFull textEnvironmental science & pollutionEurope PMC
  5. Electrospray Polytetrafluoroethylene Membranes: Effect of Composition and Heat Treatment on Mechanical Properties and Chemical Resistance
    Evgeniy Melnik, Vladimir Botvin, Kirill Shirin +5
    PolymersPeer-reviewedCC BY 4.0Full textHydrology & soilsCrossrefEurope PMC
BibTeX
@article{xu2026cyclic,
  title = {{Cyclic Fouling and Flux Recovery in a Piezoelectrically Actuated Polytetrafluoroethylene Membrane Module.}},
  author = {Shuiyang Xu and Ning Qin and Yan Guo and Pan Zhao and Tianxin Li},
  journal = {Membranes},
  year = {2026},
  month = sep,
  doi = {10.3390/membranes16100325},
  url = {https://europepmc.org/article/MED/42931003},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Cyclic Fouling and Flux Recovery in a Piezoelectrically Actuated Polytetrafluoroethylene Membrane Module.
AU  - Shuiyang Xu
AU  - Ning Qin
AU  - Yan Guo
AU  - Pan Zhao
AU  - Tianxin Li
PY  - 2026
DA  - 2026/09/29
JO  - Membranes
DO  - 10.3390/membranes16100325
UR  - https://europepmc.org/article/MED/42931003
AB  - Membrane fouling limits pressure-driven filtration by increasing hydraulic resistance and cleaning demand. Here, an external lead zirconate titanate actuator (PZT) was coupled to a passive polytetrafluoroethylene (PTFE) microfiltration membrane to examine cyclic fouling and short-term flux recovery. The primary pressure series comprised chronological sodium-alginate filtration stages at 6-30 kPa using a nominal 5 μm membrane from two membrane histories; additional actuation-duration, dosing, imaging, and interfacial analyses were treated as separate evidence streams. Across 31 adjacent activation events, endpoint flux increased in 28 events and decreased in three, with a median change of 1351 L/m²h. These events were repeated observations within the two histories and did not constitute independent replicates or a matched sham control. Segment-wise Hermia fitting retained 39 decline windows, for which cake filtration gave the minimum Akaike information criterion (AIC) in 34 windows (87.2%); however, the selected model was recovered in fewer than 80% of bootstrap resamples for 15 windows, underscoring that the fits are empirical descriptors rather than unique mechanism identifiers. The measured real electrical input was about 1.5 W, whereas the estimated viscosity-related flux gain from the recorded temperature change was only 0.08-2.68%, indicating that bulk heating alone could not explain the observed recovery. Separate microscopy and extended Derjaguin-Landau-Verwey-Overbeek (XDLVO) analyses were consistent with removal or redistribution of surface deposits and altered post-treatment attachment propensity. Overall, the data establish a reproducible within-history temporal association between actuator operation and flux recovery, while the absence of a matched sham experiment precludes attribution to a single mechanical, hydraulic, electrical, or pressure-transient pathway.
SN  - 2077-0375
ER  -