PreprintCC BY 4.0arXiv
Absolute frequency measurement of a 176Lu+ (3D1) standard against the NRC-FCs2 fountain with 2.6×10−16 uncertainty
Abstract
We report an improved absolute frequency measurement of the 176Lu+ (3D1) optical frequency standard, evaluated via a remote link to the NRC-FCs2 caesium fountain primary frequency standard. Operating a single ion clock with 94.2% uptime over 10 days, and using an ambiguity-resolved precise point positioning (PPP-AR) link over the Global Positioning System, we determine an absolute frequency of 353 638 794 073 800.332(91)Hz at a fractional uncertainty of 2.6 × 10−16. This agrees with our previous result, which underpins the Comité international des poids et mesures recommended frequency value, and reduces the uncertainty by a factor of 3.6.
Versions
Related
- Absolute frequency measurement of the 40Ca+ clock transition using a GNSS link to the SI second
- Absolute Experimental Measurement of Intrinsic Helicity in Elementary Plasmonic Nanostructures
- Practical Mid-infrared Dual-comb Spectroscopy with Absolute Frequency Referencing Based on a Single-cavity Dual-comb Fiber Laser
- Absolute intensity measurement of pulsed muon beams using in-beam activation
- General Quantum Circuit Framework for Extended Wigner’s Friend Scenarios: Logically and Causally Consistent Reasoning without Absolute Measurement Events
BibTeX
@misc{arnold2026absolute,
title = {{Absolute frequency measurement of a $^176$Lu$^+\,(^3\mathrmD_1)$ standard against the NRC-FCs2 fountain with $2.6\times10^-16$ uncertainty}},
author = {K. J. Arnold and Bin Jian and Zhao Zhang and Qi Zhao and Qin Qichen and N. Jayjong and M. D. K. Lee and Scott Beattie and M. D. Barrett},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2607.07044},
eprint = {2607.07044},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2607.07044},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Absolute frequency measurement of a ^176Lu^+ (^3D_1) standard against the NRC-FCs2 fountain with 2.6×10^−16 uncertainty
AU - K. J. Arnold
AU - Bin Jian
AU - Zhao Zhang
AU - Qi Zhao
AU - Qin Qichen
AU - N. Jayjong
AU - M. D. K. Lee
AU - Scott Beattie
AU - M. D. Barrett
PY - 2026
DA - 2026/09/28
PB - arXiv
DO - 10.48550/arxiv.2607.07044
UR - https://arxiv.org/abs/2607.07044
AB - We report an improved absolute frequency measurement of the ^176Lu^+ (^3D_1) optical frequency standard, evaluated via a remote link to the NRC-FCs2 caesium fountain primary frequency standard. Operating a single ion clock with 94.2% uptime over 10 days, and using an ambiguity-resolved precise point positioning (PPP-AR) link over the Global Positioning System, we determine an absolute frequency of 353 638 794 073 800.332(91)Hz at a fractional uncertainty of 2.6 × 10^−16. This agrees with our previous result, which underpins the Comité international des poids et mesures recommended frequency value, and reduces the uncertainty by a factor of 3.6.
ER -