Practical Mid-infrared Dual-comb Spectroscopy with Absolute Frequency Referencing Based on a Single-cavity Dual-comb Fiber Laser

Abstract

We demonstrate a practical mid-infrared (MIR) dual-comb spectroscopy (DCS) method based on a bidirectional dual-comb fiber laser. By exploiting the inherently high relative stability and mutual coherence of the dual-comb laser, we stabilize the MIR dual-comb modes with sufficient precision using only piezoelectric control of the repetition frequencies. This simple configuration enables correction of residual timing jitter and phase noise in interferograms while preserving the absolute optical frequency scale defined by the experimentally obtained comb parameters, without requiring an external continuous-wave laser reference or tight phase-locking. Importantly, the proposed method does not merely produce apparently clean interferograms through signal processing, but enables coherent averaging while retaining both the physically meaningful interferometric waveforms and well-defined absolute frequency information. The proposed system is experimentally validated through MIR spectroscopy of N2O around 3.9 μm, achieving a signal-to-noise ratio of approximately 690 through coherent averaging of 10,000 interferograms over 65 s, along with the acquisition of an absorption spectrum consistent with the reference data. These results demonstrate a simple and practical approach to absolute-frequency-referenced MIR-DCS.

Related

  1. The James Webb Space Telescope Absolute Flux Calibration. VI. Near-infrared Camera Imaging and Coronagraphy
    Martha L. Boyer, Benjamin Sunnquist, Bryan Hilbert +4
    The Astronomical JournalPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationCrossref
  2. Absolute calibration of scintillators for laser-driven ion spectroscopy using in situ CR-39 sampling detectors
    Wei Lin, Tzu-Yao Huang, Shih-Fan Yang +9
    arXivPreprintCC BY-NC-ND 4.0Full textApplied physics & instrumentationPlasma physicsarXiv
  3. Absolute frequency measurement of a 176Lu+ (3D1) standard against the NRC-FCs2 fountain with 2.6×10−16 uncertainty
    K. J. Arnold, Bin Jian, Zhao Zhang +6
  4. Absolute frequency measurement of the 40Ca+ clock transition using a GNSS link to the SI second
    M. Guevara-Bertsch, M. K. Joshi, M. I Hussain +2
  5. Ultraviolet to Infrared Spectroscopy of the Type Ibn SN 2023tsz Suggests a Lower-mass Progenitor
    Sergiy S Vasylyev, Griffin Hosseinzadeh, Luc Dessart +42
    HALPreprintLicence not statedGeneral astronomyGeneral physicsHAL
BibTeX
@misc{asahara2026practical,
  title = {{Practical Mid-infrared Dual-comb Spectroscopy with Absolute Frequency Referencing Based on a Single-cavity Dual-comb Fiber Laser}},
  author = {Akifumi Asahara and Kaoru Minoshima},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.17822},
  eprint = {2610.17822},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.17822},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Practical Mid-infrared Dual-comb Spectroscopy with Absolute Frequency Referencing Based on a Single-cavity Dual-comb Fiber Laser
AU  - Akifumi Asahara
AU  - Kaoru Minoshima
PY  - 2026
DA  - 2026/10/13
PB  - arXiv
DO  - 10.48550/arxiv.2610.17822
UR  - https://arxiv.org/abs/2610.17822
AB  - We demonstrate a practical mid-infrared (MIR) dual-comb spectroscopy (DCS) method based on a bidirectional dual-comb fiber laser. By exploiting the inherently high relative stability and mutual coherence of the dual-comb laser, we stabilize the MIR dual-comb modes with sufficient precision using only piezoelectric control of the repetition frequencies. This simple configuration enables correction of residual timing jitter and phase noise in interferograms while preserving the absolute optical frequency scale defined by the experimentally obtained comb parameters, without requiring an external continuous-wave laser reference or tight phase-locking. Importantly, the proposed method does not merely produce apparently clean interferograms through signal processing, but enables coherent averaging while retaining both the physically meaningful interferometric waveforms and well-defined absolute frequency information. The proposed system is experimentally validated through MIR spectroscopy of N_2O around 3.9 μm, achieving a signal-to-noise ratio of approximately 690 through coherent averaging of 10,000 interferograms over 65 s, along with the acquisition of an absorption spectrum consistent with the reference data. These results demonstrate a simple and practical approach to absolute-frequency-referenced MIR-DCS.
ER  -