Skip to content
DraconiticResearch
Search Sources API
197,693 studies31 sourcesUpdated 21 min ago
Peer-reviewedCC BY 4.0Polymers

Study of Hybrid Epoxy Resin Composites Reinforced with E-CR Glass Fiber/Polypropylene: Moisture Behavior, Mechanical Strength, and Acoustic Damage Mitigation Under Marine Aging Conditions

  1. 1Centro de Investigación Científica de Yucatán, A. C. Unidad de Materiales, Calle 43 No. 130 x 32 y 34, Colonia Chuburná de Hidalgo, Merida 97205, Yucatan, Mexico
  2. 2Tecnológico Nacional de México/Campus ITS_Calkiní. C. A. Bioprocesos, Av. Ah-Canul, Calkini 24900, Campeche, Mexico

Abstract

The durability of fiber-reinforced epoxy composites in marine environments depends on the interaction among interfacial characteristics, moisture transport, and damage evolution. However, it remains poorly understood whether E-CR/PP hybridization merely provides a secondary reinforcing phase or also modifies moisture-transport and load-transfer mechanisms. This study investigated the effects of incorporating E-CR glass fibers and polypropylene (PP) fibers on moisture absorption, mechanical response, and damage development in an epoxy matrix. The reinforced composites were subjected to short-term seawater immersion for up to 30 days. FTIR-ATR, AFM, micromechanical testing, moisture absorption and diffusion analysis, flexural testing, and acoustic emission were combined to relate surface characteristics and interfacial behavior to moisture transport and mechanical performance. The neat epoxy matrix showed progressive moisture uptake and a 22.03% reduction in acoustic-wave propagation velocity, consistent with moisture-induced plasticization and reduced effective stiffness. The incorporation of 5 wt.% PP was associated with lower moisture uptake in composites containing equivalent E-CR contents and with a reduction in the estimated effective diffusion coefficient. The CPPV formulation, containing 50 wt.% E-CR and 5 wt.% PP, exhibited the lowest measured moisture uptake (1.20%) and effective diffusion coefficient (2.96 × 10−12 m2 s−1) among the formulations investigated during the early immersion period. After 30 days of seawater immersion, CPPV exhibited a residual flexural strength of approximately 600 MPa, compared with approximately 420 MPa for the corresponding 50 wt.% E-CR composite without PP (CFV). These findings indicate that PP does not act solely as a secondary reinforcing phase; rather, E-CR/PP hybridization modifies the effective moisture-transport environment and load-transfer response of the epoxy composite. Within the 30-day exposure period investigated, the hybrid architecture therefore provided improved resistance to moisture ingress and higher residual flexural strength. Longer-term exposure studies are required to establish whether these advantages persist under prolonged marine aging.

Related

  1. Development of hybrid polypropylene composites reinforced with chemically modified rice straw and foxtail millet husk for EV automotive applications
    Megha Tirumala Sai Tangellamudi, G. Prasanthi, Shankaracharya M. Sutar
    Scientific ReportsPeer-reviewedCC BYFull textMaterials & polymersDOAJ
  2. Mechanical Recovery of Damaged Glass Fiber Reinforced Polypropylene via Repetitive Sub-Melting Thermal Annealing: A Molecular and Structural Study
    Tetsuo Takayama, Jun Funabashi
    PolymersPeer-reviewedCC BYFull textMaterials & polymersEurope PMCCrossref
  3. Flow-Induced Structuring of Polypropylene-Based Composites for Improved Mechanical and Thermal Performance
    Rossella Arrigo, Mohammad Parhami Alamdari, Alberto Frache
    PolymersPeer-reviewedCC BY 4.0Full textMaterials & polymersCrossrefEurope PMC
  4. Comparative study of chemical treatments on the mechanical and moisture absorption behavior of coccinia indica fiber-reinforced epoxy composites
    Bhuvaneshwaran Mylsamy, P. S. Sampath, Karthik Aruchamy +3
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textMaterials & polymersCrossref
  5. Investigation of crack initiation, and mechanical behavior of polypropylene and polymer-based composites under plastic deformation in automotive brake fluid reservoirs
    Liang Jian Chun, Ying Quanjia, Yang Bin +6
    PLOS OnePeer-reviewedCC BY 4.0Full textMaterials & polymersPLOS
BibTeX
@article{borgespalomo2026study,
  title = {{Study of Hybrid Epoxy Resin Composites Reinforced with E-CR Glass Fiber/Polypropylene: Moisture Behavior, Mechanical Strength, and Acoustic Damage Mitigation Under Marine Aging Conditions}},
  author = {Dunyansed Sarine Borges-Palomo and Carlos Rolando Ríos-Soberanis and Roberto Carlos Anaya-Ramírez and Alejandro Ortiz-Fernández and Emilio Pérez-Pacheco},
  journal = {Polymers},
  year = {2026},
  month = nov,
  doi = {10.3390/polym18212758},
  url = {https://www.mdpi.com/2073-4360/18/21/2758},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Study of Hybrid Epoxy Resin Composites Reinforced with E-CR Glass Fiber/Polypropylene: Moisture Behavior, Mechanical Strength, and Acoustic Damage Mitigation Under Marine Aging Conditions
AU  - Dunyansed Sarine Borges-Palomo
AU  - Carlos Rolando Ríos-Soberanis
AU  - Roberto Carlos Anaya-Ramírez
AU  - Alejandro Ortiz-Fernández
AU  - Emilio Pérez-Pacheco
PY  - 2026
DA  - 2026/11/05
JO  - Polymers
DO  - 10.3390/polym18212758
UR  - https://www.mdpi.com/2073-4360/18/21/2758
AB  - The durability of fiber-reinforced epoxy composites in marine environments depends on the interaction among interfacial characteristics, moisture transport, and damage evolution. However, it remains poorly understood whether E-CR/PP hybridization merely provides a secondary reinforcing phase or also modifies moisture-transport and load-transfer mechanisms. This study investigated the effects of incorporating E-CR glass fibers and polypropylene (PP) fibers on moisture absorption, mechanical response, and damage development in an epoxy matrix. The reinforced composites were subjected to short-term seawater immersion for up to 30 days. FTIR-ATR, AFM, micromechanical testing, moisture absorption and diffusion analysis, flexural testing, and acoustic emission were combined to relate surface characteristics and interfacial behavior to moisture transport and mechanical performance. The neat epoxy matrix showed progressive moisture uptake and a 22.03% reduction in acoustic-wave propagation velocity, consistent with moisture-induced plasticization and reduced effective stiffness. The incorporation of 5 wt.% PP was associated with lower moisture uptake in composites containing equivalent E-CR contents and with a reduction in the estimated effective diffusion coefficient. The CPPV formulation, containing 50 wt.% E-CR and 5 wt.% PP, exhibited the lowest measured moisture uptake (1.20%) and effective diffusion coefficient (2.96 × 10−12 m2 s−1) among the formulations investigated during the early immersion period. After 30 days of seawater immersion, CPPV exhibited a residual flexural strength of approximately 600 MPa, compared with approximately 420 MPa for the corresponding 50 wt.% E-CR composite without PP (CFV). These findings indicate that PP does not act solely as a secondary reinforcing phase; rather, E-CR/PP hybridization modifies the effective moisture-transport environment and load-transfer response of the epoxy composite. Within the 30-day exposure period investigated, the hybrid architecture therefore provided improved resistance to moisture ingress and higher residual flexural strength. Longer-term exposure studies are required to establish whether these advantages persist under prolonged marine aging.
SN  - 2073-4360
ER  -