Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 30 min ago
Peer-reviewedCC BY-NC-NDBMC cancer

Integrating a Ripple Filter into Pencil Beam Scanning Proton Therapy for Breast Cancer: from Dosimetric Feasibility to Acute Toxicity Assessment.

8 affiliations
  1. 1Department of Medical Physics, Shanghai Proton and Heavy Ion Center, 4365 Kangxin Road, Shanghai, Pudong, 201321, China.
  2. 2Shanghai Key Laboratory of Radiation Oncology, Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy, Shanghai, China.
  3. 3Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, 4365 Kangxin Road, Shanghai, Pudong, 201321, China.
  4. 4Department of Radiation Oncology, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, 4365 Kangxin Road, Shanghai, Pudong, 201321, China.
  5. 5Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, 4365 Kangxin Road, Shanghai, Pudong, 201321, China. [email protected].
  6. 6Shanghai Key Laboratory of Radiation Oncology, Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy, Shanghai, China. [email protected].
  7. 7Department of Radiation Oncology, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, 4365 Kangxin Road, Shanghai, Pudong, 201321, China. [email protected].
  8. 8Shanghai Key Laboratory of Radiation Oncology, Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy, Shanghai, China. [email protected].

Abstract

Background

Pencil beam scanning (PBS) proton therapy (PT) offers superior dosimetric advantages for breast cancer treatment. However, synchrotron-based facilities frequently encounter throughput limitations due to slow energy layer switching, particularly problematic for superficial targets requiring numerous energy layers. Although ripple filters (RiFis) can mitigate this constraint by broadening the Bragg peak, their application in breast cancer PT remains unexplored. This study comprehensively investigates the feasibility, efficiency gains, linear energy transfer (LET) characteristics, and clinical safety of integrating a RiFi into PBS PT for breast cancer.Methods

We conducted a two-phase investigation beginning with a dosimetric planning study and proceeding to clinical validation. In phase Ⅰ, we generated paired treatment plans (RiFi vs. non-RiFi) for 21 patients (11 breast-conserving surgery [BCS] and 10 modified radical mastectomy [MRM]) to compare target coverage, organ-at-risk (OAR) sparing, dose-averaged LET (LETd) distributions, and number of energy layers. In phase Ⅱ, we conducted a retrospective analysis of 99 BCS patients treated between January and December 2025, employing 1:1 multivariate matching to control for treatment volume and prescription dose, resulting in 37 well-balanced pairs. Dose-volume and LETd parameters, Acute toxicities and treatment delivery time were compared between matched groups.Results

In phase Ⅰ dosimetric study, RiFi plans maintained robust target coverage (V95). However, the broadened beam introduced slight but statistically significant increments in doses to OARs. For BCS patients, the mean ipsilateral lung dose and mean heart dose increased by 0.13 Gy(RBE) (95% confidence interval [CI]: 0.08-0.28 Gy(RBE), p < .001) and 0.04 Gy(RBE) (95% CI: 0.02-0.06 Gy(RBE), p = .006), respectively. For MRM patients, the mean ipsilateral lung dose and mean heart dose increased by 0.79 Gy(RBE) (95% CI: 0.46-1.10 Gy(RBE), p = .002) and 0.08 Gy(RBE) (95% CI: 0.04-0.19 Gy(RBE), p = .009), respectively. Conversely, the RiFi significantly decreased LETd by 0.15-0.65 keV/µm to skin and distal OARs. Phase Ⅱ clinical validation demonstrated similar LETd reduction and no significant differences in the incidence or severity of acute radiation-induced dermatitis or esophagitis between groups. RiFi integration significantly enhanced treatment efficiency, reducing actual beam delivery time by approximately 20%.Conclusions

Integrating a RiFi into breast cancer PBS PT effectively improves delivery efficiency and mitigates distal high-LETd exposure, albeit at the cost of slight increments in low-dose exposure to distal OARs. Clinical data confirm this dosimetric change does not compromise acute safety for BCS patients. These findings suggest that the RiFi is a feasible option for improving treatment delivery efficiency in synchrotron-based PT systems.

Related

  1. CBCT-Guided Online Adaptive Ultrahypofractionated Whole-Breast Radiotherapy for Early-Stage Breast Cancer: Dosimetric Outcomes and Acute Toxicity.
    Giovanni Ursi, Matea Lekić, Hrvoje Kaučić +5
    Current oncology (Toronto, Ont.)Peer-reviewedCC BYFull textApplied physics & instrumentationEurope PMC
  2. Exploratory machine-learning evaluation of clinical and dosimetric features in late prostate radiotherapy toxicity.
    Karl Jordan, Christopher J Talbot, John D Kelleher +2
    Clinical and translational radiation oncologyPeer-reviewedCC BY-NC-NDFull textApplied physics & instrumentationEurope PMCPMC
  3. Field junction technique in MRI‐guided ultra‐hypofractionated radiotherapy for a long continuous target volume in prostate cancer: First clinical application, dosimetric and early toxicity outcomes
    Lingling Yan, Shirui Qin, Meng Liang +6
    Journal of Applied Clinical Medical PhysicsPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMC
  4. Dosimetric feasibility of lattice radiotherapy for bulky tumors: a paired VMAT vs. helical tomotherapy comparison - the STRYKE trial
    Mottareale R, Serra M, Pezzulla D +18
    Frontiers in OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationCrossrefEurope PMCPMC
  5. Preliminary Feasibility and Dosimetric Evaluation of Retroperitoneal Hydrogel Spacer Placement for Stereotactic Body Radiation Therapy: A Cadaveric Study
    Shin Tanabe, Kotaro Yoshio, Takaaki Komiyama +9
    Advances in Radiation OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMC
BibTeX
@article{sun2026integrating,
  title = {{Integrating a Ripple Filter into Pencil Beam Scanning Proton Therapy for Breast Cancer: from Dosimetric Feasibility to Acute Toxicity Assessment.}},
  author = {Wei Sun and Weiwei Wang and Qing Zhang and Jingfang Zhao and Ping Li},
  journal = {BMC cancer},
  year = {2026},
  month = aug,
  doi = {10.1186/s12885-026-16601-2},
  url = {https://europepmc.org/article/MED/43009815},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Integrating a Ripple Filter into Pencil Beam Scanning Proton Therapy for Breast Cancer: from Dosimetric Feasibility to Acute Toxicity Assessment.
AU  - Wei Sun
AU  - Weiwei Wang
AU  - Qing Zhang
AU  - Jingfang Zhao
AU  - Ping Li
PY  - 2026
DA  - 2026/08/13
JO  - BMC cancer
DO  - 10.1186/s12885-026-16601-2
UR  - https://europepmc.org/article/MED/43009815
AB  - Background  Pencil beam scanning (PBS) proton therapy (PT) offers superior dosimetric advantages for breast cancer treatment. However, synchrotron-based facilities frequently encounter throughput limitations due to slow energy layer switching, particularly problematic for superficial targets requiring numerous energy layers. Although ripple filters (RiFis) can mitigate this constraint by broadening the Bragg peak, their application in breast cancer PT remains unexplored. This study comprehensively investigates the feasibility, efficiency gains, linear energy transfer (LET) characteristics, and clinical safety of integrating a RiFi into PBS PT for breast cancer.Methods  We conducted a two-phase investigation beginning with a dosimetric planning study and proceeding to clinical validation. In phase Ⅰ, we generated paired treatment plans (RiFi vs. non-RiFi) for 21 patients (11 breast-conserving surgery [BCS] and 10 modified radical mastectomy [MRM]) to compare target coverage, organ-at-risk (OAR) sparing, dose-averaged LET (LETd) distributions, and number of energy layers. In phase Ⅱ, we conducted a retrospective analysis of 99 BCS patients treated between January and December 2025, employing 1:1 multivariate matching to control for treatment volume and prescription dose, resulting in 37 well-balanced pairs. Dose-volume and LETd parameters, Acute toxicities and treatment delivery time were compared between matched groups.Results  In phase Ⅰ dosimetric study, RiFi plans maintained robust target coverage (V95). However, the broadened beam introduced slight but statistically significant increments in doses to OARs. For BCS patients, the mean ipsilateral lung dose and mean heart dose increased by 0.13 Gy(RBE) (95% confidence interval [CI]: 0.08-0.28 Gy(RBE), p < .001) and 0.04 Gy(RBE) (95% CI: 0.02-0.06 Gy(RBE), p = .006), respectively. For MRM patients, the mean ipsilateral lung dose and mean heart dose increased by 0.79 Gy(RBE) (95% CI: 0.46-1.10 Gy(RBE), p = .002) and 0.08 Gy(RBE) (95% CI: 0.04-0.19 Gy(RBE), p = .009), respectively. Conversely, the RiFi significantly decreased LETd by 0.15-0.65 keV/µm to skin and distal OARs. Phase Ⅱ clinical validation demonstrated similar LETd reduction and no significant differences in the incidence or severity of acute radiation-induced dermatitis or esophagitis between groups. RiFi integration significantly enhanced treatment efficiency, reducing actual beam delivery time by approximately 20%.Conclusions  Integrating a RiFi into breast cancer PBS PT effectively improves delivery efficiency and mitigates distal high-LETd exposure, albeit at the cost of slight increments in low-dose exposure to distal OARs. Clinical data confirm this dosimetric change does not compromise acute safety for BCS patients. These findings suggest that the RiFi is a feasible option for improving treatment delivery efficiency in synchrotron-based PT systems.
SN  - 1471-2407
ER  -