Field junction technique in MRI‐guided ultra‐hypofractionated radiotherapy for a long continuous target volume in prostate cancer: First clinical application, dosimetric and early toxicity outcomes
- 1Department of Radiation Oncology National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College Beijing China
Abstract
Background: MRI‐guided radiotherapy (MRIgRT) on a 1.5 T MR‐Linac is constrained by a 22 cm maximum field length, limiting long continuous planning target volumes (PTVs). A dual‐isocenter field‐junction technique has been previously validated in a phantom study. This work presents its first clinical application in hypofractionated prostate radiotherapy.
Materials and Methods: A 79‐year‐old prostate cancer patient had six contiguous target volumes (PTV, CTV4000, PTVpubis, PGTVpubis, PTVp and PGTVnd), treated over 5 fractions with prescribed doses to the respective target volumes. PTVp was divided into PTVpup and PTVpdn, with a field overlap region between them. Two composite volumes were created: inferior volume (PTV, CTV4000, PTVpubis, PGTVpubis, PTVpdn) and superior volume (PTVpup, PGTVnd), each with its own isocenter. The inferior volume followed the adapt‐to‐shape (ATS) workflow. During its delivery, the superior volume was first optimized offline on daily MR images using dose feathering approach based on the inferior dose distribution. The optimized plan was then transferred for online adapt‐to‐position (ATP) adaptation. The inferior and superior volumes were combined offline for dose summation. The ArcCHECK phantom and ArcherQA Monte Carlo method were used for dose verification. Patient‐reported outcomes, including FACT‐P questionnaires, were collected during the 3‐month follow‐up.
Results: Treatment was delivered over 5 alternate‐day fractions. ArcCHECK phantom gamma passing rates, using 3%/2 mm with a 10% threshold, were 96.7%, 97.1%, and 96.0% for the inferior, superior and composite reference plans, respectively. Daily ArcherQA showed consistently high passing rates across five fractions: 97.08%–98.43% for the inferior and 98.12%–98.74% for the superior volumes. CTV4000, PTV, PTVpubis and PGTVpub all met prescribed doses. PGTVnd and PTVp had intermittent underdose relative to initial prescriptions, but all fractions met second prescription limits. Organ at risks (OARs) constraints, especially for rectum and bladder, remained within tolerance across all fractions. Total treatment time decreased from 112 min in the first fraction to 80 min in the fifth fraction. FACT‐P score declined from 69.17 at baseline to 55.5 at end‐of‐RT, partially recovering to 57.5 at 2.5 months. No urological or gastrointestinal toxicity was reported during follow‐up.
Conclusion: The proposed two‐isocenter field junction technique is clinically feasible for MRIgRT of long continuous prostate cancer PTVs. It provides a practical solution for treating long PTVs on a 1.5 T MR‐Linac.
Related
- Hypofractionated and conventionally fractionated radiotherapy for synchronous bilateral breast cancer: clinical and dosimetric outcomes
- Microbeam radiotherapy - clinical and dosimetric investigation of a first clinical application.
- Dosimetric Feasibility of Hypofractionated Radiation Therapy with Simultaneously Integrated Central Boost for Retroperitoneal Sarcoma.
- Feasibility of Urethra-Sparing Ultra-Hypofractionated Three-Dose-Level Radiotherapy for Prostate Cancer with a Dominant Intraprostatic Lesion Abutting the High-Dose Avoidance Zone.
- The impact of electron streaming in head and neck cancer patients treated with ultra-hypofractionated MR-guided radiotherapy
BibTeX
@article{yan2026field,
title = {{Field junction technique in MRI‐guided ultra‐hypofractionated radiotherapy for a long continuous target volume in prostate cancer: First clinical application, dosimetric and early toxicity outcomes}},
author = {Lingling Yan and Shirui Qin and Meng Liang and Qianhui Xu and Ningyu Wang and Meng Sun and Kuo Men and Jianrong Dai and Ningning Lu},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
month = nov,
doi = {10.1002/acm2.70899},
url = {https://doi.org/10.1002/acm2.70899},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Field junction technique in MRI‐guided ultra‐hypofractionated radiotherapy for a long continuous target volume in prostate cancer: First clinical application, dosimetric and early toxicity outcomes
AU - Lingling Yan
AU - Shirui Qin
AU - Meng Liang
AU - Qianhui Xu
AU - Ningyu Wang
AU - Meng Sun
AU - Kuo Men
AU - Jianrong Dai
AU - Ningning Lu
PY - 2026
DA - 2026/11/19
JO - Journal of Applied Clinical Medical Physics
DO - 10.1002/acm2.70899
UR - https://doi.org/10.1002/acm2.70899
AB - Background: MRI‐guided radiotherapy (MRIgRT) on a 1.5 T MR‐Linac is constrained by a 22 cm maximum field length, limiting long continuous planning target volumes (PTVs). A dual‐isocenter field‐junction technique has been previously validated in a phantom study. This work presents its first clinical application in hypofractionated prostate radiotherapy. Materials and Methods: A 79‐year‐old prostate cancer patient had six contiguous target volumes (PTV, CTV4000, PTVpubis, PGTVpubis, PTVp and PGTVnd), treated over 5 fractions with prescribed doses to the respective target volumes. PTVp was divided into PTVpup and PTVpdn, with a field overlap region between them. Two composite volumes were created: inferior volume (PTV, CTV4000, PTVpubis, PGTVpubis, PTVpdn) and superior volume (PTVpup, PGTVnd), each with its own isocenter. The inferior volume followed the adapt‐to‐shape (ATS) workflow. During its delivery, the superior volume was first optimized offline on daily MR images using dose feathering approach based on the inferior dose distribution. The optimized plan was then transferred for online adapt‐to‐position (ATP) adaptation. The inferior and superior volumes were combined offline for dose summation. The ArcCHECK phantom and ArcherQA Monte Carlo method were used for dose verification. Patient‐reported outcomes, including FACT‐P questionnaires, were collected during the 3‐month follow‐up. Results: Treatment was delivered over 5 alternate‐day fractions. ArcCHECK phantom gamma passing rates, using 3%/2 mm with a 10% threshold, were 96.7%, 97.1%, and 96.0% for the inferior, superior and composite reference plans, respectively. Daily ArcherQA showed consistently high passing rates across five fractions: 97.08%–98.43% for the inferior and 98.12%–98.74% for the superior volumes. CTV4000, PTV, PTVpubis and PGTVpub all met prescribed doses. PGTVnd and PTVp had intermittent underdose relative to initial prescriptions, but all fractions met second prescription limits. Organ at risks (OARs) constraints, especially for rectum and bladder, remained within tolerance across all fractions. Total treatment time decreased from 112 min in the first fraction to 80 min in the fifth fraction. FACT‐P score declined from 69.17 at baseline to 55.5 at end‐of‐RT, partially recovering to 57.5 at 2.5 months. No urological or gastrointestinal toxicity was reported during follow‐up. Conclusion: The proposed two‐isocenter field junction technique is clinically feasible for MRIgRT of long continuous prostate cancer PTVs. It provides a practical solution for treating long PTVs on a 1.5 T MR‐Linac.
SN - 1526-9914
ER -