Long-term performance of non-ALD MCP-PMTs in the high-radiation environment of ALICE

Abstract

The Fast Interaction Trigger detector of the ALICE apparatus at the LHC includes a Cherenkov subsystem utilizing 52 Planacon XP85002/FIT-Q microchannel plate-based photomultiplier tubes. It is a precise trigger, multiplicity and luminosity detector located in the forward region, where the flux of collision products is the largest. The photon load reaches up to 2*10^8 photoelectrons / cm^2 / s for the innermost photosensors, corresponding to 0.4 μA / cm^2 average anode current density. The lifetime-extended version of the Planacon MCP-PMT with atomic layer deposition cannot handle such a large anode current. We therefore use the non-ALD version of the Planacons that, on the other hand, suffer from a limited lifetime in terms of the integrated anode charge. Here we present the long-term performance trends of the non-ALD Planacons up to the integrated anode charge of 2 C / cm^2. We demonstrate that the low-gain operation strategy allows to maintain excellent time resolution in multiphoton mode unchanged up to that large integrated charge. While the majority of the equally illuminated MCP-PMTs feature almost identical ageing speed, two outliers suffering from a faster ageing coincide with the outliers in the noise characteristics measured prior to the irradiation. Moreover, we report that the effective ageing speed is partially suppressed by the self-recovery of the response of aged MCP-PMTs newly observed by our group during months-long no-beam periods.

Related

  1. Long-term 3+1 simulations of primordial black hole formation during radiation domination
    Zhuan Ning, Rong-Gen Cai, Shao-Jiang Wang +1
    arXivPreprintarXiv licenceFull textCosmologyGravitation & general relativityarXiv
  2. Cryogenic performance and long-term stability of Hamamatsu R8520-506 photomultiplier tubes in liquid argon
    Jilong Yin, Gaoshuang Li, Yike Shu +1
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  3. Search for long-lived dark photons from hidden radiation at the LHC
    Chuan-Ren Chen, Van Que Tran
    Journal of High Energy PhysicsPeer-reviewedCC BY 4.0Full textHigh-energy & particle physicsCrossref
  4. Performance and Radiation Damage of the Heavy-Ion Silicon Beam Tracker in the BM@N Experiment
    D. Chemezov, S. Khabarov, Yu. Kopylov +6
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  5. Packaging and long-term temperature-cycling evaluation of a nine-channel polymer AWG for O-band LAN-WDM
    Shangci Yang, Daming Zhang, Bing Li +4
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
BibTeX
@misc{collaboration2026longterm,
  title = {{Long-term performance of non-ALD MCP-PMTs in the high-radiation environment of ALICE}},
  author = {Yury Melikyan for the ALICE Collaboration},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.06069},
  eprint = {2609.06069},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.06069},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Long-term performance of non-ALD MCP-PMTs in the high-radiation environment of ALICE
AU  - Yury Melikyan for the ALICE Collaboration
PY  - 2026
DA  - 2026/09/05
PB  - arXiv
DO  - 10.48550/arxiv.2609.06069
UR  - https://arxiv.org/abs/2609.06069
AB  - The Fast Interaction Trigger detector of the ALICE apparatus at the LHC includes a Cherenkov subsystem utilizing 52 Planacon XP85002/FIT-Q microchannel plate-based photomultiplier tubes. It is a precise trigger, multiplicity and luminosity detector located in the forward region, where the flux of collision products is the largest. The photon load reaches up to 2*10^8 photoelectrons / cm^2 / s for the innermost photosensors, corresponding to 0.4 μA / cm^2 average anode current density. The lifetime-extended version of the Planacon MCP-PMT with atomic layer deposition cannot handle such a large anode current. We therefore use the non-ALD version of the Planacons that, on the other hand, suffer from a limited lifetime in terms of the integrated anode charge. Here we present the long-term performance trends of the non-ALD Planacons up to the integrated anode charge of 2 C / cm^2. We demonstrate that the low-gain operation strategy allows to maintain excellent time resolution in multiphoton mode unchanged up to that large integrated charge. While the majority of the equally illuminated MCP-PMTs feature almost identical ageing speed, two outliers suffering from a faster ageing coincide with the outliers in the noise characteristics measured prior to the irradiation. Moreover, we report that the effective ageing speed is partially suppressed by the self-recovery of the response of aged MCP-PMTs newly observed by our group during months-long no-beam periods.
ER  -