Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 12 min ago
Peer-reviewedCC BYLangmuir : the ACS journal of surfaces and colloids

Separating Detection Performance from Thermodynamic Interpretability in Quantum-Capacitance Affinity Assays.

  1. 1Institute of Chemistry, Department of Physics and Mathematics, São Paulo State University (UNESP), Araraquara, SP14800-060, Brazil.
  2. 2Centro Interdisciplinar de Química e Bioloxía (CICA) and Departamento de Química, Facultade de Ciencias, Universidade da Coruña, 15071A Coruña, Galicia, Spain.

Abstract

Quantum capacitance, Cq, is proportional to the electronic density of states of a redox monolayer and is used as a label-free transducer in affinity sensing. Here, we develop a theoretical framework and apply it to a reanalysis of previously published impedance data from a DNA-receptive interface; no new experimental data are reported. Under the isoscopic condition, the charging energy per accessible redox state is fixed at 2kBT, so that the analyte dependence of the ensemble Cq resides in the number of accessible states. Binding renders a fraction χ of these states electrochemically inaccessible, which gives a relative response of 1/Cq equal to χθ/(1 - χθ) and an apparent affinity Kaapp = (1 - χ)Ka. Because the titration does not reach saturation, only the product χθ is determined: χ is not identifiable, being bounded below at 0.169 (unamplified) and 0.625 (amplified with ferrocenecarboxylic acid, FcA), so that Ka cannot be recovered from Kaapp. The charge-relaxation resistance, 12.97 ± 0.72 kΩ, lies within 0.5% of h/2e2 and is invariant across the unamplified titration, an internal consistency criterion that the amplified configuration fails. The Cole-Cole exponent of the electronic relaxation, α = 0.888 ± 0.042, is invariant with concentration but does not establish that the receptor sites are energetically equivalent. The calibration is log-linear over five decades, a shape no Langmuir isotherm reproduces, and equilibrium was not independently established; the extracted constants are therefore reported as apparent, protocol-dependent interfacial parameters. The analysis separates analytical detection performance, including the previously reported attomolar detection limit of the FcA-amplified interface, from thermodynamic interpretability, which requires an identifiable χ, an invariant Rq and a demonstrated equilibrium.

Related

  1. Capacitance-based measurement of calcium-mediated vesicle fusion upon microinjection in droplet interface bilayers
    McKayla Torbett-Dougherty, Thomas Shaw, Beliz Utebay +8
    ChemRxivPreprintCC BYFull textMolecular biology & gene regulationChemRxiv
  2. Attribution assignment for deep-generative sequence models enables interpretability analysis using positive-only data
    Robert Frank, Michael Widrich, Rahmad Akbar +4
    PLOS Computational BiologyPeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationImmunologyPLOS
  3. A compact generative language model learns the compositional grammar of phase-separating proteins
    Abdul Wasim, Ushasi Pramanik, Anirban Das +3
    Chemical sciencePeer-reviewedCC BY-NCFull textMolecular biology & gene regulationEurope PMCEurope PMCPMC
  4. Thermodynamic Model and Experiments Indicate Kinetically Trapped States in Ionisable Lipid Nanoparticles
    E. Kostyurina, A. Sudarsan, M. Huber +4
    bioRxivPreprintAll rights reservedFull textBiophysicsbioRxiv
  5. A conserved thermodynamic signature links transcriptome organization to growth state
    R. Zivieri, J. Reeves, S. Pattnaik +5
    bioRxivPreprintAll rights reservedFull textBiophysicsbioRxiv
BibTeX
@article{carr2026separating,
  title = {{Separating Detection Performance from Thermodynamic Interpretability in Quantum-Capacitance Affinity Assays.}},
  author = {Olivia Carr and Paulo Roberto Bueno},
  journal = {Langmuir : the ACS journal of surfaces and colloids},
  year = {2026},
  month = oct,
  doi = {10.1021/acs.langmuir.6c03092},
  url = {https://europepmc.org/article/MED/42918140},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Separating Detection Performance from Thermodynamic Interpretability in Quantum-Capacitance Affinity Assays.
AU  - Olivia Carr
AU  - Paulo Roberto Bueno
PY  - 2026
DA  - 2026/10/01
JO  - Langmuir : the ACS journal of surfaces and colloids
DO  - 10.1021/acs.langmuir.6c03092
UR  - https://europepmc.org/article/MED/42918140
AB  - Quantum capacitance, Cq, is proportional to the electronic density of states of a redox monolayer and is used as a label-free transducer in affinity sensing. Here, we develop a theoretical framework and apply it to a reanalysis of previously published impedance data from a DNA-receptive interface; no new experimental data are reported. Under the isoscopic condition, the charging energy per accessible redox state is fixed at 2kBT, so that the analyte dependence of the ensemble Cq resides in the number of accessible states. Binding renders a fraction χ of these states electrochemically inaccessible, which gives a relative response of 1/Cq equal to χθ/(1 - χθ) and an apparent affinity Kaapp = (1 - χ)Ka. Because the titration does not reach saturation, only the product χθ is determined: χ is not identifiable, being bounded below at 0.169 (unamplified) and 0.625 (amplified with ferrocenecarboxylic acid, FcA), so that Ka cannot be recovered from Kaapp. The charge-relaxation resistance, 12.97 ± 0.72 kΩ, lies within 0.5% of h/2e2 and is invariant across the unamplified titration, an internal consistency criterion that the amplified configuration fails. The Cole-Cole exponent of the electronic relaxation, α = 0.888 ± 0.042, is invariant with concentration but does not establish that the receptor sites are energetically equivalent. The calibration is log-linear over five decades, a shape no Langmuir isotherm reproduces, and equilibrium was not independently established; the extracted constants are therefore reported as apparent, protocol-dependent interfacial parameters. The analysis separates analytical detection performance, including the previously reported attomolar detection limit of the FcA-amplified interface, from thermodynamic interpretability, which requires an identifiable χ, an invariant Rq and a demonstrated equilibrium.
SN  - 0743-7463
SN  - 1520-5827
ER  -