Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 39 min ago
PreprintCC BY 4.0arXiv

A novel vortex generator for enhancing bileaflet mechanical heart valve performance proposed through detailed hemodynamic and data-driven dynamic mode decomposition studies

Abstract

Prosthetic mechanical heart valves (MHVs), particularly the bileaflet types, have been one of the most advanced and commonly implanted heart valves for more than four decades. These bileaflet mechanical heart valves (BMHVs) offer superior durability and improved hemodynamics; however, they have certain drawbacks, including the need for lifelong anticoagulation to prevent blood clot formation and the associated risks of thromboembolism. To overcome these limitations, comprehensive research studies are deployed, among which controlling the overall hemodynamics by means of passive interventions, such as placing (multiple) vortex generators (VGs) on the heart valve leaflets, is one possibility. These VGs, in particular, are known to delay the separation of boundary layers formed around the leaflet surfaces, provided they are precisely positioned and have their chosen design features. Limited research has shown that VGs improve hemodynamics beyond a BHMV when rectangular-type VGs (RVGs) are considered. Specifically, configurations such as co-rotating and counter-rotating are investigated at an incidence angle of 23∘; however, their location on the heart valve leaflets and their shape can prove vital, an aspect that has not been explored so far. Suffice it to add, the alteration in hemodynamic performance due to these VGs may often lead to an impact on several critical clinical indices such as the pressure gradients, turbulent intensity, wall shear stress (WSS), blood damage (BD), etc., which typically establish the overall functional efficiency of an MHV.

Related

  1. Société de Biomécanique senior investigator award 2024—Hemodynamic performance of a bicuspid venous valve: A computational study
    Barthelemy Thibaud, Simon Mendez, Franck Nicoud
    Journal of BiomechanicsPeer-reviewedCC BY 4.0Full textGeneral biologyCardiovascular medicineHAL
  2. Optimization of curved vortex generator geometry for enhanced thermal performance in water-to-air finned-tube heat exchanger
    Josip Batista, Anica Trp, Kristian Lenić +1
    arXivPreprintCC BY-NC-ND 4.0Full textComputational physicsFluid dynamicsarXiv
  3. 3D-Printed Sustainable PLA/Flax Sandwich Panels Featuring Antitrichiral Cores: Effects of Geometry Parameters, and Density on Mechanical Performance
    Anis Hamrouni, Kamel Bousnina, Jean-Luc Rebiere +3
    International Applied MechanicsPreprintCC BYFull textGeneral physicsHAL
  4. Natural CaCO₃ improves the moisture resistance and mechanical performance of hemp-starch biocomposites: A multi-objective optimization study
    Sameh Balti, Chadi Maalouf, Tala Moussa +7
    Case Studies in Construction MaterialsPeer-reviewedCC BY 4.0Full textEnvironmental science & pollutionGeneral physicsHAL
  5. Dilute Zn alloying in biodegradable Mg wires: microstructure, mechanical performance, and degradation behavior
    Jiří Ryjáček, Leonard Hlodák, Jiří Liška +3
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
BibTeX
@misc{chauhan2026novel,
  title = {{A novel vortex generator for enhancing bileaflet mechanical heart valve performance proposed through detailed hemodynamic and data-driven dynamic mode decomposition studies}},
  author = {A. Chauhan and C. Sasmal},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.20856},
  eprint = {2609.20856},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.20856},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - A novel vortex generator for enhancing bileaflet mechanical heart valve performance proposed through detailed hemodynamic and data-driven dynamic mode decomposition studies
AU  - A. Chauhan
AU  - C. Sasmal
PY  - 2026
DA  - 2026/09/01
PB  - arXiv
DO  - 10.48550/arxiv.2609.20856
UR  - https://arxiv.org/abs/2609.20856
AB  - Prosthetic mechanical heart valves (MHVs), particularly the bileaflet types, have been one of the most advanced and commonly implanted heart valves for more than four decades. These bileaflet mechanical heart valves (BMHVs) offer superior durability and improved hemodynamics; however, they have certain drawbacks, including the need for lifelong anticoagulation to prevent blood clot formation and the associated risks of thromboembolism. To overcome these limitations, comprehensive research studies are deployed, among which controlling the overall hemodynamics by means of passive interventions, such as placing (multiple) vortex generators (VGs) on the heart valve leaflets, is one possibility. These VGs, in particular, are known to delay the separation of boundary layers formed around the leaflet surfaces, provided they are precisely positioned and have their chosen design features. Limited research has shown that VGs improve hemodynamics beyond a BHMV when rectangular-type VGs (RVGs) are considered. Specifically, configurations such as co-rotating and counter-rotating are investigated at an incidence angle of 23^∘; however, their location on the heart valve leaflets and their shape can prove vital, an aspect that has not been explored so far. Suffice it to add, the alteration in hemodynamic performance due to these VGs may often lead to an impact on several critical clinical indices such as the pressure gradients, turbulent intensity, wall shear stress (WSS), blood damage (BD), etc., which typically establish the overall functional efficiency of an MHV.
ER  -