Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 14 min ago
Peer-reviewedCC BY 4.0Polymers

Flexible Surface Acoustic Wave Sensor Based on an SXFA Sensitive Film for DMMP Detection

  1. 1State Key Laboratory of Chemistry for NBC Hazards Protection, Beijing 102205, China

Abstract

Rapid and reliable detection of organophosphorus nerve agents is essential for public safety and individual protection. In this work, a flexible surface acoustic wave (SAW) gas sensor based on a hexafluoroisopropyl (HFIP)-functionalized polysiloxane (SXFA) sensitive film was developed for the detection of dimethyl methylphosphonate (DMMP), a widely used simulant of sarin (GB). SXFA was synthesized through a two-step route and systematically characterized by Fourier-transform infrared spectroscopy (FTIR), 1H/19F/13C nuclear magnetic resonance (NMR), gel permeation chromatography (GPC), differential scanning calorimetry (DSC), thermogravimetric analysis (TGA) and scanning transmission electron microscopy coupled with energy-dispersive X-ray spectroscopy (STEM/EDX). The results confirm the successful incorporation of HFIP groups and reveal a low glass-transition temperature (Tg = −23.5 °C, ΔCp = 0.295 J·g−1·K−1), a weight-average molecular weight of ~3200 g·mol−1, a thermal-stability limit of ~200 °C, and a characteristic HFIP side-chain cleavage at 343.4 °C with a final residue of 18.37%. The flexible device consisted of a polyimide (PI) substrate, a magnetron-sputtered AlN piezoelectric layer and silver interdigital transducers (IDTs) and operated at a center frequency of ~200 MHz; a rigid quartz-based delay line was used as a reference. The dependence of the insertion loss (IL) on film thickness was described by a third-order polynomial (R2 = 0.960), from which an optimal thickness window of 150–450 nm was identified, and 450 nm gave the best gas-sensing performance (response 23.5 mV at 3 mg·m−3 DMMP, IL −16.0 dB; mean ± SD, n = 3 independently prepared devices per thickness). The optimized sensor exhibited a linear response to DMMP from 0.4 to 6 mg·m−3 (y = 30.88x + 8.988, R2 = 0.9985) at 28.1 °C, fast response and recovery (~75 s each), excellent reproducibility (relative standard deviation, RSD = 0.50%, n = 7), pronounced selectivity towards DMMP and DFP over common interferents, and a 60-day response retention of 96.0%. The sensing mechanism is attributed to hydrogen-bonding adsorption between the acidic HFIP groups and the basic P=O moiety of DMMP, combined with mass-loading and film-viscoelastic effects. These results demonstrate that SXFA-functionalized flexible SAW devices are promising candidates for wearable and low-power detection of organophosphorus nerve agents.

Related

  1. Interfacially Assembled Hollow AuAg Nanostars on Flexible PDMS for Sensitive SERS Detection
    Jiatong Li, Meiyu Liu, Xinyuan Meng +4
    Molecules (Basel, Switzerland)Peer-reviewedCC BYFull textMaterials & polymersEurope PMCCrossref
  2. A highly sensitive carbon quantum dots sensor for hypochlorite ion detection through fluorescence-off method
    Ankita Dutta, Sahidul Islam, Ujjwal Mandal
    RSC advancesPeer-reviewedCC BYFull textMaterials & polymersEurope PMCPMC
  3. Region-Functionalized Laser-Induced Graphene Sensor Array for Flexible and Intelligent Multi-Gas Detection
    Wengan Wang, Chaoqi Zhang, Guiyong Chen +4
    NanomaterialsPeer-reviewedCC BY 4.0Full textMaterials & polymersCrossrefEurope PMC
  4. Flexible Strain Sensor Based on TPU/CNTs/rGO Conductive Membrane with Dual-Microcrack Structure for High-Performance Wearable Sensing
    Jinlong Chen, Binghao Xing, Yuexin Wang +10
    Nanomaterials (Basel, Switzerland)Peer-reviewedCC BYFull textMaterials & polymersEurope PMCCrossref
  5. Electrochemiluminescence Sensor for Uric Acid Detection Using Natural Enzyme‐Confined Nanozyme Cascade
    Lanlan Wu, Xiaochun Deng, Jiyang Liu
    LuminescencePeer-reviewedLicence not stated8 citedAnalytical chemistryOpenAlex
BibTeX
@article{yan2026flexible,
  title = {{Flexible Surface Acoustic Wave Sensor Based on an SXFA Sensitive Film for DMMP Detection}},
  author = {Cancan Yan and Yanze Wang and Junchao Yang and Jie Yang and Lin Zhang and Yong Pan and Genwei Zhang},
  journal = {Polymers},
  year = {2026},
  month = oct,
  doi = {10.3390/polym18212651},
  url = {https://www.mdpi.com/2073-4360/18/21/2651},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Flexible Surface Acoustic Wave Sensor Based on an SXFA Sensitive Film for DMMP Detection
AU  - Cancan Yan
AU  - Yanze Wang
AU  - Junchao Yang
AU  - Jie Yang
AU  - Lin Zhang
AU  - Yong Pan
AU  - Genwei Zhang
PY  - 2026
DA  - 2026/10/26
JO  - Polymers
DO  - 10.3390/polym18212651
UR  - https://www.mdpi.com/2073-4360/18/21/2651
AB  - Rapid and reliable detection of organophosphorus nerve agents is essential for public safety and individual protection. In this work, a flexible surface acoustic wave (SAW) gas sensor based on a hexafluoroisopropyl (HFIP)-functionalized polysiloxane (SXFA) sensitive film was developed for the detection of dimethyl methylphosphonate (DMMP), a widely used simulant of sarin (GB). SXFA was synthesized through a two-step route and systematically characterized by Fourier-transform infrared spectroscopy (FTIR), 1H/19F/13C nuclear magnetic resonance (NMR), gel permeation chromatography (GPC), differential scanning calorimetry (DSC), thermogravimetric analysis (TGA) and scanning transmission electron microscopy coupled with energy-dispersive X-ray spectroscopy (STEM/EDX). The results confirm the successful incorporation of HFIP groups and reveal a low glass-transition temperature (Tg = −23.5 °C, ΔCp = 0.295 J·g−1·K−1), a weight-average molecular weight of ~3200 g·mol−1, a thermal-stability limit of ~200 °C, and a characteristic HFIP side-chain cleavage at 343.4 °C with a final residue of 18.37%. The flexible device consisted of a polyimide (PI) substrate, a magnetron-sputtered AlN piezoelectric layer and silver interdigital transducers (IDTs) and operated at a center frequency of ~200 MHz; a rigid quartz-based delay line was used as a reference. The dependence of the insertion loss (IL) on film thickness was described by a third-order polynomial (R2 = 0.960), from which an optimal thickness window of 150–450 nm was identified, and 450 nm gave the best gas-sensing performance (response 23.5 mV at 3 mg·m−3 DMMP, IL −16.0 dB; mean ± SD, n = 3 independently prepared devices per thickness). The optimized sensor exhibited a linear response to DMMP from 0.4 to 6 mg·m−3 (y = 30.88x + 8.988, R2 = 0.9985) at 28.1 °C, fast response and recovery (~75 s each), excellent reproducibility (relative standard deviation, RSD = 0.50%, n = 7), pronounced selectivity towards DMMP and DFP over common interferents, and a 60-day response retention of 96.0%. The sensing mechanism is attributed to hydrogen-bonding adsorption between the acidic HFIP groups and the basic P=O moiety of DMMP, combined with mass-loading and film-viscoelastic effects. These results demonstrate that SXFA-functionalized flexible SAW devices are promising candidates for wearable and low-power detection of organophosphorus nerve agents.
SN  - 2073-4360
ER  -