Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 44 min ago
Peer-reviewedCC BY 4.0Journal of Materials Chemistry C

Key parameters for reliable biosensing using organic photoelectrochemical transistors: a case study on bilirubin detection

Abstract

Organic photoelectrochemical transistors (OPECTs) combine the biocompatibility of organic electrochemical transistors with light-driven operation, offering a promising platform for biosensing. Yet, their full potential remains untapped due to overlooked operating parameters. In this work, we investigate the influence of four key factors-source-drain voltage, light power density, co-solvent electrochemical response, and analyte color-on the response of OPECTs. We show that operating at negative source-drain voltages (e.g., -0.5 V) enhances signal amplification, while low light power density (e.g., <5 mW cm-2 ) is enough to saturate the OPECT response. Using unconjugated bilirubin detection as a case study, we also reveal how co-solvents like DMSO and colored analytes (e.g., conjugated bilirubin and biliverdin) can interfere with the sensor response, leading to misleading results. By addressing these often-overlooked parameters, we provide practical guidelines to improve the accuracy, reproducibility, and detection limits of OPECT-based biosensors, paving the way for more reliable and portable diagnostic tools.

Related

  1. A Dual-Gate OECT Platform for Drift-Suppressed and High-Sensitivity Real-Time Biosensing
    S. J. Kissovsky, S. T. Keene, G. G. Malliaras +1
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
  2. Bilirubin statistically accounts for the association between Enterobacterales lineage and Mayo endoscopic score in ulcerative colitis: a cross-sectional associational variable analysis.
    Zhengyu Ren, Junni Ma, Siyao Wang +4
    Frontiers in medicinePeer-reviewedCC BYFull textGenetics & genomicsEurope PMCPMC
  3. Steric attenuation of membrane-associated dimerization-induced fluorescence for cell-free biosensing
    Parsa Parvizian, Hossein Moghimianavval, Allen P Liu
    bioRxivPreprintCC BY-NC-NDFull textSystems & synthetic biologybioRxivPMC
  4. Life cycle assessment of bilirubin oxidase production and its use for enzymatic solubilization of lignin at neutral pH
    Anish Koyamparambath, Daye Lee, Olga P Fuentes +6
    Cleaner Environmental SystemsPeer-reviewedCC BY 4.0Full textSystems & synthetic biologyMaterials & polymersHAL
  5. Differential sensing with imprinted and non-imprinted organic electrochemical transistors reduces calibration drift in wearable sweat cortisol sensors
    L. I. Almofeez, M. S. Islam, T. S. Ambagahawaththa +1
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
BibTeX
@article{errafi2026parameters,
  title = {{Key parameters for reliable biosensing using organic photoelectrochemical transistors: a case study on bilirubin detection}},
  author = {Wissal Errafi and Stella Schuster and Maryem Rahmani and Alessandra Pistillo and Paloma Carrascal Marquez and Nicolas Zimmermann and Nicolas Leclerc and Thomas Cottineau and Olivier Bardagot},
  journal = {Journal of Materials Chemistry C},
  year = {2026},
  month = aug,
  doi = {10.1039/d6tc01397j},
  url = {https://hal.science/hal-05794712v1},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Key parameters for reliable biosensing using organic photoelectrochemical transistors: a case study on bilirubin detection
AU  - Wissal Errafi
AU  - Stella Schuster
AU  - Maryem Rahmani
AU  - Alessandra Pistillo
AU  - Paloma Carrascal Marquez
AU  - Nicolas Zimmermann
AU  - Nicolas Leclerc
AU  - Thomas Cottineau
AU  - Olivier Bardagot
PY  - 2026
DA  - 2026/08/25
JO  - Journal of Materials Chemistry C
DO  - 10.1039/d6tc01397j
UR  - https://hal.science/hal-05794712v1
AB  - Organic photoelectrochemical transistors (OPECTs) combine the biocompatibility of organic electrochemical transistors with light-driven operation, offering a promising platform for biosensing. Yet, their full potential remains untapped due to overlooked operating parameters. In this work, we investigate the influence of four key factors-source-drain voltage, light power density, co-solvent electrochemical response, and analyte color-on the response of OPECTs. We show that operating at negative source-drain voltages (e.g., -0.5 V) enhances signal amplification, while low light power density (e.g., <5 mW cm-2 ) is enough to saturate the OPECT response. Using unconjugated bilirubin detection as a case study, we also reveal how co-solvents like DMSO and colored analytes (e.g., conjugated bilirubin and biliverdin) can interfere with the sensor response, leading to misleading results. By addressing these often-overlooked parameters, we provide practical guidelines to improve the accuracy, reproducibility, and detection limits of OPECT-based biosensors, paving the way for more reliable and portable diagnostic tools.
SN  - 2050-7526
SN  - 2050-7534
ER  -