Skip to content
DraconiticResearch
Search Sources API
277,308 studies31 sourcesUpdated 37 min ago
Peer-reviewedCC BY-NC-NDJournal of thoracic disease

Computed tomography (CT)-guided fiducial placement for lung nodule localization: a single-center experience.

  1. 1Department of Surgery, Corewell Health William Beaumont University Hospital, Royal Oak, MI, USA.
  2. 2Oakland University William Beaumont School of Medicine, Rochester, MI, USA.

Abstract

With the adoption of low-dose computed tomography (CT) for lung cancer screening, small lung nodules are increasingly detected. Sublobar resection has been shown to be oncologically equivalent to lobectomy for peripheral lung cancers ≤2 cm and appropriate for small pulmonary metastases, necessitating localization methods for non-anatomic wedge resection. Preoperative CT-guided metal fiducial placement with intraoperative fluoroscopy is one such method. We hypothesized that this technique would enable high resection success with few complications. We performed a single-institution retrospective review of patients undergoing lung nodule resection preceded by CT-guided fiducial placement between 12/2022-2/2025. Fiducial placement was successful in 38 consecutive patients. Complications included hemorrhage [3 (8%), self-limited] and pneumothorax [7 (18%); 3 (8%) requiring pigtail catheter]. All fiducials were identified at the time of surgery. Six nodules could be identified by visualization or palpation alone. Operative plans changed in 3 (8%) cases: one lobectomy after three failed wedge resections, and two cases where the fiducial was not retrieved, but resection was deemed adequate. On final pathology, 29 (76%) patients had adenocarcinoma, 5 (13%) had metastases, and 4 (11%) had non-cancerous lesions. All cancer specimens had negative margins with a median distance to the closest cut margin of 1.4 cm (IQR, 0.7-1.9 cm), and the median lung nodule size was 1.2 cm (IQR, 1.0-1.5 cm). CT-guided fiducial placement is a reliable localization method. Pneumothorax requiring intervention occurred in 8% of cases. Nearly all fiducials and suspicious lesions were successfully removed via wedge resection. Compared to other methods of nodule localization, CT-guided fiducial placement was generally well tolerated with a high success rate and few complications, was resource-efficient, and demonstrated prolonged intraparenchymal stability. Further studies, including cost assessments, are needed to compare localization methods.

Related

  1. Level-Specific Analysis of Intraoperative Computed Tomography–Navigated vs Fluoroscopy-Assisted Lumbar Pedicle Screw Placement Accuracy: A Retrospective Cohort Study
    Mario Giordano, Federico Iaccarino, Amir Kaywan Aftahy +3
    International Journal of Spine SurgeryPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  2. Cone-Beam Computed Tomography (CBCT)-Guided Surgical Guide for Implant Placement Following Failed Endodontic Retreatment and Alveolar Ridge Preservation: A Case Report
    Keily J Portillo Avila, Zela Murray, Daymariher Orta Pedroza +2
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Computed tomography-guided percutaneous puncture injection of methylene blue mixed with autologous blood for preoperative localization of pulmonary nodules: analysis of 407 cases
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  4. Valve Expectoration After Endobronchial Valve Placement: Potential Utility of Computed Tomography‐Based Airway Sizing—A Case Report
    Daisuke Kinose, Yukihiro Nagatani, Hiroaki Nakagawa +10
    Respirology Case ReportsPeer-reviewedCC BY 4.0Full textGeneral medicinePMCEurope PMC
  5. Immediate Implant Placement With Peri-Implant Contour Augmentation in the Maxillary Central Incisor: A Three-Year Clinical and Cone-Beam Computed Tomography Follow-Up
    B Tanuja, A Ramesh, Haritha Kotha +2
    CureusPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
BibTeX
@article{ward2026computed,
  title = {{Computed tomography (CT)-guided fiducial placement for lung nodule localization: a single-center experience.}},
  author = {Katelyn R Ward and Ryan Davis and Varun Vadnala and Min Kim and Kimberly Aung and Hayley Henderson and Terrence Metz and Thomas J Watson},
  journal = {Journal of thoracic disease},
  year = {2026},
  month = sep,
  doi = {10.21037/jtd-2026-0691},
  url = {https://europepmc.org/article/MED/42996675},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Computed tomography (CT)-guided fiducial placement for lung nodule localization: a single-center experience.
AU  - Katelyn R Ward
AU  - Ryan Davis
AU  - Varun Vadnala
AU  - Min Kim
AU  - Kimberly Aung
AU  - Hayley Henderson
AU  - Terrence Metz
AU  - Thomas J Watson
PY  - 2026
DA  - 2026/09/28
JO  - Journal of thoracic disease
DO  - 10.21037/jtd-2026-0691
UR  - https://europepmc.org/article/MED/42996675
AB  - With the adoption of low-dose computed tomography (CT) for lung cancer screening, small lung nodules are increasingly detected. Sublobar resection has been shown to be oncologically equivalent to lobectomy for peripheral lung cancers ≤2 cm and appropriate for small pulmonary metastases, necessitating localization methods for non-anatomic wedge resection. Preoperative CT-guided metal fiducial placement with intraoperative fluoroscopy is one such method. We hypothesized that this technique would enable high resection success with few complications. We performed a single-institution retrospective review of patients undergoing lung nodule resection preceded by CT-guided fiducial placement between 12/2022-2/2025. Fiducial placement was successful in 38 consecutive patients. Complications included hemorrhage [3 (8%), self-limited] and pneumothorax [7 (18%); 3 (8%) requiring pigtail catheter]. All fiducials were identified at the time of surgery. Six nodules could be identified by visualization or palpation alone. Operative plans changed in 3 (8%) cases: one lobectomy after three failed wedge resections, and two cases where the fiducial was not retrieved, but resection was deemed adequate. On final pathology, 29 (76%) patients had adenocarcinoma, 5 (13%) had metastases, and 4 (11%) had non-cancerous lesions. All cancer specimens had negative margins with a median distance to the closest cut margin of 1.4 cm (IQR, 0.7-1.9 cm), and the median lung nodule size was 1.2 cm (IQR, 1.0-1.5 cm). CT-guided fiducial placement is a reliable localization method. Pneumothorax requiring intervention occurred in 8% of cases. Nearly all fiducials and suspicious lesions were successfully removed via wedge resection. Compared to other methods of nodule localization, CT-guided fiducial placement was generally well tolerated with a high success rate and few complications, was resource-efficient, and demonstrated prolonged intraparenchymal stability. Further studies, including cost assessments, are needed to compare localization methods.
SN  - 2072-1439
SN  - 2077-6624
ER  -