Skip to content
DraconiticResearch
Search Sources API
277,308 studies31 sourcesUpdated 47 min ago
Peer-reviewedCC BY 4.0Respirology Case Reports

Valve Expectoration After Endobronchial Valve Placement: Potential Utility of Computed Tomography‐Based Airway Sizing—A Case Report

1 more authors
  1. 1Department of Respiratory Medicine Shiga University of Medical Science Otsu Shiga Japan
  2. 2Department of Radiology Shiga University of Medical Science Otsu Shiga Japan
  3. 3Health Administration Center Shiga University of Medical Science Otsu Shiga Japan

Abstract

A 75‐year‐old man with chronic obstructive pulmonary disease underwent endobronchial valve (EBV) placement in the left lower lobe and expectorated the valve from left B10 1 month later. Retrospective analysis of preprocedural dynamic computed tomography (CT) images showed that the median B10 luminal diameter increased from 4.25 mm at end‐expiration to 6.55 mm at end‐inspiration, approaching the upper limit of the recommended working range (4.0–7.0 mm) for the initially placed size 4.0 valve. A size 5.5 valve was subsequently placed without further expectoration. Bronchoscopic sizing under general anaesthesia with neuromuscular blockade and positive‐pressure ventilation may underestimate the maximum airway calibre encountered during spontaneous breathing, particularly in dependent bronchi. Inspiratory CT‐based airway assessment may provide useful complementary information for planning EBV placement and selecting an appropriate valve size.

Related

  1. Level-Specific Analysis of Intraoperative Computed Tomography–Navigated vs Fluoroscopy-Assisted Lumbar Pedicle Screw Placement Accuracy: A Retrospective Cohort Study
    Mario Giordano, Federico Iaccarino, Amir Kaywan Aftahy +3
    International Journal of Spine SurgeryPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  2. Cone-Beam Computed Tomography (CBCT)-Guided Surgical Guide for Implant Placement Following Failed Endodontic Retreatment and Alveolar Ridge Preservation: A Case Report
    Keily J Portillo Avila, Zela Murray, Daymariher Orta Pedroza +2
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Immediate Implant Placement With Peri-Implant Contour Augmentation in the Maxillary Central Incisor: A Three-Year Clinical and Cone-Beam Computed Tomography Follow-Up
    B Tanuja, A Ramesh, Haritha Kotha +2
    CureusPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  4. Remnant preservation and stump suturing in anterior cruciate ligament reconstruction reduce tibial tunnel widening without compromising tunnel placement: A computed tomography-based randomised controlled trial.
    Mahmoud El-Desouky, Ahmed Samir Elkalyoby, Amr Samir Rashwan +2
    Journal of experimental orthopaedicsPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMC
  5. Computed tomography (CT)-guided fiducial placement for lung nodule localization: a single-center experience.
    Katelyn R Ward, Ryan Davis, Varun Vadnala +5
    Journal of thoracic diseasePeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMCPMC
BibTeX
@article{kinose2026valve,
  title = {{Valve Expectoration After Endobronchial Valve Placement: Potential Utility of Computed Tomography‐Based Airway Sizing—A Case Report}},
  author = {Daisuke Kinose and Yukihiro Nagatani and Hiroaki Nakagawa and Mayu Fujino and Amane Ichida and Reo Tanaka and Shogo Okuda and Yasumitsu Ueki and Masashi Misonou and Akio Yamazaki and Emiko Ogawa and Masafumi Yamaguchi and Yasutaka Nakano},
  journal = {Respirology Case Reports},
  year = {2026},
  month = nov,
  doi = {10.1002/rcr2.70817},
  url = {https://doi.org/10.1002/rcr2.70817},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Valve Expectoration After Endobronchial Valve Placement: Potential Utility of Computed Tomography‐Based Airway Sizing—A Case Report
AU  - Daisuke Kinose
AU  - Yukihiro Nagatani
AU  - Hiroaki Nakagawa
AU  - Mayu Fujino
AU  - Amane Ichida
AU  - Reo Tanaka
AU  - Shogo Okuda
AU  - Yasumitsu Ueki
AU  - Masashi Misonou
AU  - Akio Yamazaki
AU  - Emiko Ogawa
AU  - Masafumi Yamaguchi
AU  - Yasutaka Nakano
PY  - 2026
DA  - 2026/11/09
JO  - Respirology Case Reports
DO  - 10.1002/rcr2.70817
UR  - https://doi.org/10.1002/rcr2.70817
AB  - A 75‐year‐old man with chronic obstructive pulmonary disease underwent endobronchial valve (EBV) placement in the left lower lobe and expectorated the valve from left B10 1 month later. Retrospective analysis of preprocedural dynamic computed tomography (CT) images showed that the median B10 luminal diameter increased from 4.25 mm at end‐expiration to 6.55 mm at end‐inspiration, approaching the upper limit of the recommended working range (4.0–7.0 mm) for the initially placed size 4.0 valve. A size 5.5 valve was subsequently placed without further expectoration. Bronchoscopic sizing under general anaesthesia with neuromuscular blockade and positive‐pressure ventilation may underestimate the maximum airway calibre encountered during spontaneous breathing, particularly in dependent bronchi. Inspiratory CT‐based airway assessment may provide useful complementary information for planning EBV placement and selecting an appropriate valve size.
SN  - 2051-3380
ER  -