Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 30 min ago
PreprintCC BY-NC-NDbioRxiv

Phase-noise tolerant fully-coherent optical coherence tomography angiography for high-contrast 3D microvasculature mapping

  1. 1Massachusetts Institute of Technology

Abstract

Optical coherence tomography angiography (OCTA) has been extensively explored for the detection of pathological retinal changes arising in various ophthalmological diseases. Due to phase instability of conventional systems, most OCTA signal processing methods to date have relied on intensity-based averaging, despite the resulting lower contrast and dynamic range compared to coherent averaging approaches. In this work, we (1) present a novel computation pipeline that enables fully-coherent processing in any phase-stable or phase-unstable system, and (2) demonstrate the first angiography metric with integrated signal-to-noise ratio (SNR) correction and coherent spatiotemporal ensemble averaging effective in any OCT system. Our method does not rely on 2D en face projections or binarization to produce high-contrast en face views and it significantly enhances the contrast-to-noise ratio of computed OCTA volumes, particularly in regions with reduced SNR levels. Our OCTA volumes also have high cross-sectional quality, enabling the use of single-depth en face views and the localization of capillary paths in the axial dimension. We can now identify capillaries below the retinal pigment epithelium, near the lamina cribrosa in the optic cup, which was not previously possible due to low SNR. We also conducted an analysis of strategies for bias reduction in OCTA and developed the optimal method utilizing coherent spatiotemporal ensemble averaging. Because our method leverages coherent averaging across all dimensions, it provides flexibility in shaping the averaging kernel to target specific workflows. The value of this additional degree of freedom is illustrated in our vessel tracing investigations, in which the depth resolution was maximized by limiting coherent ensemble averaging to the two lateral dimensions even in presence of strong phase noise, enabling the identification of 3D features such as overlapping capillary paths.

Related

  1. Ultrahigh-resolution ophthalmic optical coherence tomography
    Wolfgang Drexler, Uwe Morgner, Ravi Ghanta +3
    Nature MedicinePeer-reviewedLicence not stated962 citedGeneral biologyHAL
  2. Imaging of non-tumorous and tumorous human brain tissues with full-field optical coherence tomography
    Osnath Assayag, Kate Grieve, Bertrand Devaux +5
    Neuroimage-ClinicalPeer-reviewedCC BY-NC-SAFull text168 citedGeneral biologyHAL
  3. Ultradeep optical coherence tomography
    S. Balakrishnan, G. Arora, S. G. Adie
    bioRxivPreprintCC BY-NC-NDFull textNeurosciencebioRxiv
  4. OphthoEvidence report: Baseline structural optical coherence tomography biomarkers as predictors of visual outcomes following full-thickness macular hole surgery: A systematic review and meta-analysis protocol
    Sahar Khademioore, João Pedro Lima, Dena Zeraatkar +8
    PLOS OnePeer-reviewedCC BY 4.0Full textNeuroscienceMedical imaging & radiologyPLOS
  5. Large Field, High Resolution Full-Field Optical Coherence Tomography: A Pre-clinical Study of Human Breast Tissue and Cancer Assessment
    Osnath Assayag, M Antoine, B Sigal-Zafrani +7
    TCRT ExpressPeer-reviewedCC BY-NC142 citedGeneral biologyHAL
BibTeX
@misc{jie2026phasenoise,
  title = {{Phase-noise tolerant fully-coherent optical coherence tomography angiography for high-contrast 3D microvasculature mapping}},
  author = {T. Jie and S. Ruiz Lopera and B. E. Bouma and N. Uribe-Patarroyo},
  howpublished = {bioRxiv},
  year = {2026},
  month = sep,
  doi = {10.64898/2026.09.30.755749},
  url = {https://www.biorxiv.org/content/10.64898/2026.09.30.755749v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - Phase-noise tolerant fully-coherent optical coherence tomography angiography for high-contrast 3D microvasculature mapping
AU  - T. Jie
AU  - S. Ruiz Lopera
AU  - B. E. Bouma
AU  - N. Uribe-Patarroyo
PY  - 2026
DA  - 2026/09/30
PB  - bioRxiv
DO  - 10.64898/2026.09.30.755749
UR  - https://www.biorxiv.org/content/10.64898/2026.09.30.755749v1
AB  - Optical coherence tomography angiography (OCTA) has been extensively explored for the detection of pathological retinal changes arising in various ophthalmological diseases. Due to phase instability of conventional systems, most OCTA signal processing methods to date have relied on intensity-based averaging, despite the resulting lower contrast and dynamic range compared to coherent averaging approaches. In this work, we (1) present a novel computation pipeline that enables fully-coherent processing in any phase-stable or phase-unstable system, and (2) demonstrate the first angiography metric with integrated signal-to-noise ratio (SNR) correction and coherent spatiotemporal ensemble averaging effective in any OCT system. Our method does not rely on 2D en face projections or binarization to produce high-contrast en face views and it significantly enhances the contrast-to-noise ratio of computed OCTA volumes, particularly in regions with reduced SNR levels. Our OCTA volumes also have high cross-sectional quality, enabling the use of single-depth en face views and the localization of capillary paths in the axial dimension. We can now identify capillaries below the retinal pigment epithelium, near the lamina cribrosa in the optic cup, which was not previously possible due to low SNR. We also conducted an analysis of strategies for bias reduction in OCTA and developed the optimal method utilizing coherent spatiotemporal ensemble averaging. Because our method leverages coherent averaging across all dimensions, it provides flexibility in shaping the averaging kernel to target specific workflows. The value of this additional degree of freedom is illustrated in our vessel tracing investigations, in which the depth resolution was maximized by limiting coherent ensemble averaging to the two lateral dimensions even in presence of strong phase noise, enabling the identification of 3D features such as overlapping capillary paths.
ER  -