Impact of interrupted and continuous suturing techniques on perfusion in rat JV-CCA End-to-Side anastomosis.
- 1Department of Neurosurgery, Tangdu Hospital, The Fourth Military Medical University, 569 Xinsi Road, Xi'an, Shaanxi, 710038, China.
- 2Department of Neurosurgery, Tangdu Hospital, The Fourth Military Medical University, 569 Xinsi Road, Xi'an, Shaanxi, 710038, China. [email protected].
Abstract
Purpose
End-to-side (ETS) anastomosis is a prevalent approach in cerebral revascularization; nevertheless, the effects of interrupted suturing (IS) versus continuous suturing (CS) methods on perfusion in tiny vessels are still contentious. This study aims to examine the effects of IS and CS procedures on the perfusion of the jugular vein (JV) to common carotid artery (CCA) ETS anastomosis in rats.Methods
Sixteen rats were randomly allocated into two groups to undergo ETS anastomosis via IS or CS. The laser speckle contrast imaging equipment was employed for postoperative perfusion evaluation by delineating the region of interest at the proximal and distal ends of the anastomosed artery and JV immediately postoperation, as well as at 1, 2, 4, and 6 h thereafter.Results
No statistically significant difference was observed in the diameter of the anastomotic stoma between the two groups. The perfusion volume of the donor and recipient vasculature increased throughout time, especially during the first two postoperative hours. No statistically significant differences were observed in vascular perfusion at both the proximal and distal ends of the anastomosed artery, as well as at JV, between the IS and CS groups at multiple monitoring intervals during a 6-h postoperative timeframe.Conclusions
The current short-term study indicates that there are no statistically significant differences in the perfusion of donor and recipient arteries shortly after surgery between the IS and CS groups in the JV-CCA ETS model in rats.
Related
- Endoscopic suturing for closure of a chronic gastrocutaneous fistula following percutaneous endoscopic gastrostomy after failed conventional endoscopic techniques
- Comparison of outcomes between iris suturing of three piece foldable intraocular lenses and retropupillary iris claw lens implantation techniques.
- Motion-robust high-resolution 3D-GRASE pseudo-continuous ASL perfusion imaging at 3T
- Simultaneous Infection Control and Reconstruction Using Continuous Local Antibiotic Perfusion in Septic Knee With Extensive Soft Tissue Defect: A Case Report
- Evaluation of the Consistency of Peri-ictal Hemodynamic Findings Revealed by Capturing More Than 3 Seizures Using 1.5-Tesla Pseudo-continuous Arterial Spin Labeling Magnetic Resonance Perfusion Imaging with Triple Post-labeling Delays: Report of 3 Cases
BibTeX
@article{li2026impact,
title = {{Impact of interrupted and continuous suturing techniques on perfusion in rat JV-CCA End-to-Side anastomosis.}},
author = {Chen Li and Jinghui Liu and Lijun Heng},
journal = {Acta neurochirurgica},
year = {2026},
month = sep,
doi = {10.1007/s00701-026-07021-z},
url = {https://europepmc.org/article/MED/43079125},
note = {CC BY},
}
RIS
TY - JOUR
TI - Impact of interrupted and continuous suturing techniques on perfusion in rat JV-CCA End-to-Side anastomosis.
AU - Chen Li
AU - Jinghui Liu
AU - Lijun Heng
PY - 2026
DA - 2026/09/01
JO - Acta neurochirurgica
DO - 10.1007/s00701-026-07021-z
UR - https://europepmc.org/article/MED/43079125
AB - Purpose End-to-side (ETS) anastomosis is a prevalent approach in cerebral revascularization; nevertheless, the effects of interrupted suturing (IS) versus continuous suturing (CS) methods on perfusion in tiny vessels are still contentious. This study aims to examine the effects of IS and CS procedures on the perfusion of the jugular vein (JV) to common carotid artery (CCA) ETS anastomosis in rats.Methods Sixteen rats were randomly allocated into two groups to undergo ETS anastomosis via IS or CS. The laser speckle contrast imaging equipment was employed for postoperative perfusion evaluation by delineating the region of interest at the proximal and distal ends of the anastomosed artery and JV immediately postoperation, as well as at 1, 2, 4, and 6 h thereafter.Results No statistically significant difference was observed in the diameter of the anastomotic stoma between the two groups. The perfusion volume of the donor and recipient vasculature increased throughout time, especially during the first two postoperative hours. No statistically significant differences were observed in vascular perfusion at both the proximal and distal ends of the anastomosed artery, as well as at JV, between the IS and CS groups at multiple monitoring intervals during a 6-h postoperative timeframe.Conclusions The current short-term study indicates that there are no statistically significant differences in the perfusion of donor and recipient arteries shortly after surgery between the IS and CS groups in the JV-CCA ETS model in rats.
SN - 0001-6268
SN - 0942-0940
ER -