Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 57 min ago
Peer-reviewedCC BYBMC ophthalmology

Comparison of outcomes between iris suturing of three piece foldable intraocular lenses and retropupillary iris claw lens implantation techniques.

  1. 1Department of Ophthalmology, Istanbul Kanuni Sultan Suleyman Education and Research Hospital, Istanbul, Turkey. [email protected].
  2. 2Department of Ophthalmology, Istanbul Bakirkoy Dr. Sadi Konuk Education and Research Hospital, Istanbul, Turkey.
  3. 3Department of Ophthalmology, Istanbul Beyoglu Eye Education and Research Hospital, Istanbul, Turkey.

Abstract

Background

To compare the clinical outcomes and complication rates between iris-fixated three-piece intraocular lenses (IF-IOLs) and retropupillary iris-claw intraocular lenses (IC-IOLs) in eyes without capsular support.Methods

This retrospective comparative case series was conducted at a single tertiary ophthalmology center. Eyes with aphakia or dislocated IOL and inadequate capsular support underwent either IF-IOL fixation or retropupillary IC-IOL implantation between 2012 and 2013. Outcomes included changes in corrected distance visual acuity (CDVA), IOL stability, and intraoperative, early (≤ 1 month), and late (> 1 month) postoperative complications.Results

Sixty-eight eyes (68 patients) were analyzed, of which 44 underwent IF-IOL and 24 underwent retropupillary IC-IOL implantation. CDVA improved significantly in both groups, from 1.36 ± 0.65 logMAR to 0.68 ± 0.61 logMAR in the IF-IOL group and from 1.02 ± 0.76 logMAR to 0.52 ± 0.33 logMAR in the retropupillary IC-IOL group. The between-group difference in logMAR improvement was not statistically significant (0.68 ± 0.77 vs. 0.47 ± 0.70; P = 0.181). Aphakia was more common in the retropupillary IC group (17/24 [70.8%] vs. 13/44 [29.5%], P = 0.002). Early postoperative complication rates were comparable between the groups (P = 1.000; Holm-adjusted P = 1.000). Follow-up duration was longer in the retropupillary IC-IOL group than in the IF-IOL group (9.0 ± 8.1 vs. 5.0 ± 4.4 months, P = 0.003). Overall late complications were more frequent in the retropupillary IC-IOL group than in the IF-IOL group (6/24 [25.0%] vs. 2/44 [4.5%]; P = 0.019; Holm-adjusted P = 0.039). Although late postoperative complications were more frequently observed in the retropupillary IC-IOL group, this association was attenuated after adjustment for follow-up duration. No endophthalmitis, suprachoroidal hemorrhage, or clinically significant pupil deformation was observed. Adjusted analysis did not identify surgical technique as an independent predictor of logMAR improvement (adjusted β = 0.191; P = 0.205).Conclusions

Both techniques provided comparable visual rehabilitation, but late postoperative complications were more frequent after retropupillary IC-IOL implantation. The small number of late events limits the strength of adjusted safety comparisons.

Related

  1. Comparison of Visual and Ocular Hemodynamic Outcomes Following Trifocal vs Bifocal Intraocular Lens Implantation in Patients With Cataract and Myopia.
    Man Xu, Yan Shao, Xing Gao +1
    Medical science monitor : international medical journal of experimental and clinical researchPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  2. Long-Term Visual and Corneal Outcomes Following Anterior and Retropupillary Artisan IOL Implantation for Crystalline Lens Dislocation in Eyes with Longer Axial Length
    Windsor Wen-Jin Chao, Howard Wen-Haur Chao, Hsiao-Ming Chao
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  3. Three-Year Functional Vision, Longitudinal Refractive Outcomes, and Patient-Reported Outcomes After Bilateral Implantation of the Extend Bessel-Optics Intraocular Lens: An Independent Real-World Ambispective Study
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Effect of residual spherical equivalent on visual outcomes of trifocal intraocular lens implantation in patients with cataracts across different refractive states
    Jin Zhou, Xue Zhan, HongLin Ye +2
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  5. Comparison of Outcomes of Anterior Chamber Intraocular Lenses with Scleral-fixated Intraocular Lenses: A Systematic Review.
    Thanigasalam Thevi, Adinegara Lutfi Abas
    Journal of ophthalmic & vision researchPeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
BibTeX
@article{zirtiloglu2026comparison,
  title = {{Comparison of outcomes between iris suturing of three piece foldable intraocular lenses and retropupillary iris claw lens implantation techniques.}},
  author = {Sibel Zirtiloglu and Yasar Kucuksumer and Cigdem Altan},
  journal = {BMC ophthalmology},
  year = {2026},
  month = aug,
  doi = {10.1186/s12886-026-05250-5},
  url = {https://europepmc.org/article/MED/43052839},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Comparison of outcomes between iris suturing of three piece foldable intraocular lenses and retropupillary iris claw lens implantation techniques.
AU  - Sibel Zirtiloglu
AU  - Yasar Kucuksumer
AU  - Cigdem Altan
PY  - 2026
DA  - 2026/08/24
JO  - BMC ophthalmology
DO  - 10.1186/s12886-026-05250-5
UR  - https://europepmc.org/article/MED/43052839
AB  - Background  To compare the clinical outcomes and complication rates between iris-fixated three-piece intraocular lenses (IF-IOLs) and retropupillary iris-claw intraocular lenses (IC-IOLs) in eyes without capsular support.Methods  This retrospective comparative case series was conducted at a single tertiary ophthalmology center. Eyes with aphakia or dislocated IOL and inadequate capsular support underwent either IF-IOL fixation or retropupillary IC-IOL implantation between 2012 and 2013. Outcomes included changes in corrected distance visual acuity (CDVA), IOL stability, and intraoperative, early (≤ 1 month), and late (> 1 month) postoperative complications.Results  Sixty-eight eyes (68 patients) were analyzed, of which 44 underwent IF-IOL and 24 underwent retropupillary IC-IOL implantation. CDVA improved significantly in both groups, from 1.36 ± 0.65 logMAR to 0.68 ± 0.61 logMAR in the IF-IOL group and from 1.02 ± 0.76 logMAR to 0.52 ± 0.33 logMAR in the retropupillary IC-IOL group. The between-group difference in logMAR improvement was not statistically significant (0.68 ± 0.77 vs. 0.47 ± 0.70; P = 0.181). Aphakia was more common in the retropupillary IC group (17/24 [70.8%] vs. 13/44 [29.5%], P = 0.002). Early postoperative complication rates were comparable between the groups (P = 1.000; Holm-adjusted P = 1.000). Follow-up duration was longer in the retropupillary IC-IOL group than in the IF-IOL group (9.0 ± 8.1 vs. 5.0 ± 4.4 months, P = 0.003). Overall late complications were more frequent in the retropupillary IC-IOL group than in the IF-IOL group (6/24 [25.0%] vs. 2/44 [4.5%]; P = 0.019; Holm-adjusted P = 0.039). Although late postoperative complications were more frequently observed in the retropupillary IC-IOL group, this association was attenuated after adjustment for follow-up duration. No endophthalmitis, suprachoroidal hemorrhage, or clinically significant pupil deformation was observed. Adjusted analysis did not identify surgical technique as an independent predictor of logMAR improvement (adjusted β = 0.191; P = 0.205).Conclusions  Both techniques provided comparable visual rehabilitation, but late postoperative complications were more frequent after retropupillary IC-IOL implantation. The small number of late events limits the strength of adjusted safety comparisons.
SN  - 1471-2415
ER  -