Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 20 min ago
Peer-reviewedCC BYSolarPACES Conference Proceedings

Development and Testing of a Cable-Actuated Heliostat

  1. 1Stellenbosch University

Abstract

Solar tower plants require cost reduction in the solar field, which represents 30-50% of plant capital costs. This study investigates cable-driven heliostats as a lower-cost alternative to conventional gear-driven systems. A 1 m2 prototype using cables, stepper motors, and worm gearboxes was built and tested. Outdoor tracking tests measured mean errors of 15-16 milliradians, exceeding the one milliradian target required for CSP applications. The main problem occurred at a pitch angle of about 75 degrees, where the unequal cable tensions caused loss of control. When operated manually, without automated control, pointing accuracy improved to 1.6-4.7 milliradians, showing the control algorithm was the limiting factor. The prototype drive mechanism cost $431/m2, representing 70% of the total system cost. Cost projection for a 48.5m2 heliostat estimated that the drive mechanism could be reduced to $7.32/m2, compared to the $16.08/m2 for the Stellio heliostat. However, these estimates assume the technical problems can be solved.

Related

  1. Development and Testing of Tools for ORM Measurements and Quadrupole Centering
    A. Pathak, E. Chen, A. Shemyakin
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
  2. Elasto-Hydrodynamic Propulsion of a Magnetically Actuated Filament
    Sohum Kapadia, Julien Chopin, Arshad Kudrolli
    arXivPreprintarXiv licenceFull textCondensed matterFluid dynamicsarXiv
  3. International Round-Robin Test of Critical Current of Superconducting Cable Sample
    T. Matsushita, M. Kiuchi, T. Masuda +12
    IEEE Transactions on Applied SuperconductivityPeer-reviewedLicence not stated2 citedCondensed matterHAL
  4. Kirigami-actuated reconfigurable topological photonic crystals.
    Mo-Dian Liu, Guobang Jiang, Jizhai Cui +3
    Nature communicationsPeer-reviewedCC BY-NC-NDFull textAtomic, molecular & optical physicsEurope PMC
  5. Cavity optomechanical magnetometer actuated by substrate bending
    D. D. Florizone, I. E. Rabuka, K. D. Hiltz +5
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
BibTeX
@article{lekholoane2026development,
  title = {{Development and Testing of a Cable-Actuated Heliostat}},
  author = {Rorisang Lekholoane and Craig McGregor},
  journal = {SolarPACES Conference Proceedings},
  year = {2026},
  month = oct,
  doi = {10.52825/solarpaces.v4i.3013},
  url = {https://doi.org/10.52825/solarpaces.v4i.3013},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Development and Testing of a Cable-Actuated Heliostat
AU  - Rorisang Lekholoane
AU  - Craig McGregor
PY  - 2026
DA  - 2026/10/24
JO  - SolarPACES Conference Proceedings
DO  - 10.52825/solarpaces.v4i.3013
UR  - https://doi.org/10.52825/solarpaces.v4i.3013
AB  - Solar tower plants require cost reduction in the solar field, which represents 30-50% of plant capital costs. This study investigates cable-driven heliostats as a lower-cost alternative to conventional gear-driven systems. A 1 m2 prototype using cables, stepper motors, and worm gearboxes was built and tested. Outdoor tracking tests measured mean errors of 15-16 milliradians, exceeding the one milliradian target required for CSP applications. The main problem occurred at a pitch angle of about 75 degrees, where the unequal cable tensions caused loss of control. When operated manually, without automated control, pointing accuracy improved to 1.6-4.7 milliradians, showing the control algorithm was the limiting factor. The prototype drive mechanism cost $431/m2, representing 70% of the total system cost. Cost projection for a 48.5m2 heliostat estimated that the drive mechanism could be reduced to $7.32/m2, compared to the $16.08/m2 for the Stellio heliostat. However, these estimates assume the technical problems can be solved.
SN  - 2751-9899
ER  -