Cavity optomechanical magnetometer actuated by substrate bending

Abstract

We describe a magnetic field sensor based on a monolithic Fabry-Perot cavity. The cavities were fabricated in a thin-film buckling process at one surface of a fused silica chip, and the chip was subsequently bonded to a giant magnetostrictive material (GMM). External magnetic fields drive flexural modes of the assembly and the associated bending stresses are efficiently mapped to changes in the cavity height, with enhanced response at kHz-range mechanical resonance frequencies. A key attribute of this platform is that the size of the transducing material is decoupled from the size of the optical cavity. The buckled cavity operates in low mode order and with moderate Q ~ 103, providing a high optomechanical coupling coefficient while also enabling a straightforward tuned-to-slope readout technique. Peak sensitivity ~ 2 pT/Hz1/2 was achieved in an unshielded laboratory environment, limited by laser phase and electronics noise in the readout system. With future reductions in these noise sources, we predict that a broadband thermomechanical-noise-limited sensitivity in the ~ 0.1 pT/Hz1/2 range is feasible.

Related

  1. Monogamy of quantum steering in exciton--cavity optomechanical system
    Hamza Harraf, Mohamed Amazioug, Rachid Ahl Laamara
    arXivPreprintarXiv licenceFull textCondensed matterOptics & photonicsarXiv
  2. Advances in quantum optomechanical control based on cavity cold-atom systems
    Baijun Li, Tianxiang Lu, Jie Wang +1
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
  3. Self-heating effect analysis of a dual cavity AlGaN/GaN MOS-HEMT biosensor with AlN/diamond substrate
    Rudra Lakshmi Prasanna, T. Srinivasa Ravi Kiran, Pidaparthy Vijaya +5
    Scientific ReportsPeer-reviewedCC BY 4.0Full textCondensed matterCrossref
  4. Magnetic Particle Magnetometer Based on Langevin Response of Superparamagnetic Nanoparticles for Remote Magnetic Field Sensing
    M. Jurj, C. McDonough, C. Bastajian +1
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
  5. Squeezing for dispersive readout of NV magnetometer
    A. M. Kozodaev, S. M. Drofa, P. G. Vilyuzhanina +9
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
BibTeX
@misc{florizone2026cavity,
  title = {{Cavity optomechanical magnetometer actuated by substrate bending}},
  author = {D. D. Florizone and I. E. Rabuka and K. D. Hiltz and I. Grobbellaar and E. F. DeCorby and A. Chen and K. G. Scheuer and R. G. DeCorby},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.28634},
  eprint = {2610.28634},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.28634},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Cavity optomechanical magnetometer actuated by substrate bending
AU  - D. D. Florizone
AU  - I. E. Rabuka
AU  - K. D. Hiltz
AU  - I. Grobbellaar
AU  - E. F. DeCorby
AU  - A. Chen
AU  - K. G. Scheuer
AU  - R. G. DeCorby
PY  - 2026
DA  - 2026/10/01
PB  - arXiv
DO  - 10.48550/arxiv.2610.28634
UR  - https://arxiv.org/abs/2610.28634
AB  - We describe a magnetic field sensor based on a monolithic Fabry-Perot cavity. The cavities were fabricated in a thin-film buckling process at one surface of a fused silica chip, and the chip was subsequently bonded to a giant magnetostrictive material (GMM). External magnetic fields drive flexural modes of the assembly and the associated bending stresses are efficiently mapped to changes in the cavity height, with enhanced response at kHz-range mechanical resonance frequencies. A key attribute of this platform is that the size of the transducing material is decoupled from the size of the optical cavity. The buckled cavity operates in low mode order and with moderate Q ~ 103, providing a high optomechanical coupling coefficient while also enabling a straightforward tuned-to-slope readout technique. Peak sensitivity ~ 2 pT/Hz1/2 was achieved in an unshielded laboratory environment, limited by laser phase and electronics noise in the readout system. With future reductions in these noise sources, we predict that a broadband thermomechanical-noise-limited sensitivity in the ~ 0.1 pT/Hz1/2 range is feasible.