Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 49 min ago
Peer-reviewedCC BYArthroplasty (London, England)

Smartwatch-based pelvic tracking system for augmented reality navigation in total hip arthroplasty: a preliminary clinical study.

  1. 1Department of Orthopaedic Surgery, Institute of Science Tokyo Hospital, 1-5-45 Yushima, Bunkyo-Ku, Tokyo, 113-8519, Japan. [email protected].
  2. 2Department of Orthopaedic Surgery, Institute of Science Tokyo Hospital, 1-5-45 Yushima, Bunkyo-Ku, Tokyo, 113-8519, Japan.

Abstract

Background

Accurate assessment of pelvic orientation is essential for acetabular cup placement during total hip arthroplasty (THA). Conventional pelvic tracking systems generally rely on dedicated tracking hardware and optical tracking infrastructure. We developed a smartwatch-based pelvic tracking system integrated with an augmented reality (AR) navigation platform and evaluated its preliminary clinical performance.Methods

This retrospective study included 30 hips of 27 consecutive patients who underwent primary THA using a smartwatch-based pelvic tracking navigation system between May 2025 and April 2026. The system utilizes a commercially available smartwatch fixed to the iliac crest as a pelvic tracking device and communicates orientation information to a smartphone-based AR navigation platform via Bluetooth. Acetabular cup orientation was evaluated using postoperative CT. Absolute radiographic inclination (RI) and anteversion (RA) errors were calculated as absolute differences between the final intraoperative navigation measurements and postoperative CT measurements.Results

The mean absolute RI error was 2.8° ± 2.1°, and the mean absolute RA error was 3.6° ± 2.2°. Postoperative CT measurements were within 5° of the final intraoperative navigation measurements for RI and RA in 86.7% and 70.0% of hips, respectively. Navigation was successfully completed in all 30 hips, with no conversion to a backup technique. Additional bench testing demonstrated reproducible smartwatch reattachment and reduction of time-dependent relative orientation differences following FPP invocation.Conclusions

This study demonstrated the feasibility of integrating a commercially available smartwatch into a pelvic tracking system for THA navigation. The smartwatch-based pelvic tracking platform achieved a preliminary range of cup-positioning accuracy without requiring continuous optical visualization of a pelvic reference marker while utilizing a compact and widely available consumer wearable device. This study represents the first step toward wearable-device-based navigation in arthroplasty.

Related

  1. From Measured Accuracy to Patient Outcome: Navigation in Total Hip Arthroplasty and Molecular Diagnosis of Periprosthetic Joint Infection: A Narrative Review
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Attention Is All You Need: A Universal Augmented Reality Surgical Navigation Framework
    D. Zhao, Y. Qiu, Y. Guo +6
    medRxivPreprintCC BY-NC-NDFull textGeneral medicinemedRxiv
  3. Navigation-Assisted and Robotic Total Hip, Knee, and Unicompartmental Arthroplasty: Reconciling Positioning Accuracy with Biomaterial Performance and Long-Term Implant Survival.
    Yasaman Tavakoli, Fatemeh Kanaani Nejad, Kartik Varsani +4
    Bioengineering (Basel, Switzerland)Peer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  4. Fluoroscopy Computer Navigation Versus Manual Fluoroscopic Acetabular Positioning in Direct Anterior Total Hip Arthroplasty: Safe Zone Compliance and Learning Curve Analysis.
    Karlos E Zepeda, Carmelo Burgio, Shrey Vachhani +4
    Arthroplasty todayPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  5. Limits of Single-Pass Retrieval-Augmented Generation for AI-Powered Cancer Care Navigation: A Comparison of Retrieval Strategies
    E. Hasan, Y. Zhang, O. Cook +10
    medRxivPreprintCC BY-NC-NDFull textEpidemiology & public healthmedRxiv
BibTeX
@article{takada2026smartwatchbased,
  title = {{Smartwatch-based pelvic tracking system for augmented reality navigation in total hip arthroplasty: a preliminary clinical study.}},
  author = {Ryohei Takada and Ryo Inokuchi and Yusuke Amano and Riko Yamashita and Toshitaka Yoshii and Hideyuki Koga},
  journal = {Arthroplasty (London, England)},
  year = {2026},
  month = nov,
  doi = {10.1186/s42836-026-00441-3},
  url = {https://europepmc.org/article/MED/42968184},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Smartwatch-based pelvic tracking system for augmented reality navigation in total hip arthroplasty: a preliminary clinical study.
AU  - Ryohei Takada
AU  - Ryo Inokuchi
AU  - Yusuke Amano
AU  - Riko Yamashita
AU  - Toshitaka Yoshii
AU  - Hideyuki Koga
PY  - 2026
DA  - 2026/11/02
JO  - Arthroplasty (London, England)
DO  - 10.1186/s42836-026-00441-3
UR  - https://europepmc.org/article/MED/42968184
AB  - Background  Accurate assessment of pelvic orientation is essential for acetabular cup placement during total hip arthroplasty (THA). Conventional pelvic tracking systems generally rely on dedicated tracking hardware and optical tracking infrastructure. We developed a smartwatch-based pelvic tracking system integrated with an augmented reality (AR) navigation platform and evaluated its preliminary clinical performance.Methods  This retrospective study included 30 hips of 27 consecutive patients who underwent primary THA using a smartwatch-based pelvic tracking navigation system between May 2025 and April 2026. The system utilizes a commercially available smartwatch fixed to the iliac crest as a pelvic tracking device and communicates orientation information to a smartphone-based AR navigation platform via Bluetooth. Acetabular cup orientation was evaluated using postoperative CT. Absolute radiographic inclination (RI) and anteversion (RA) errors were calculated as absolute differences between the final intraoperative navigation measurements and postoperative CT measurements.Results  The mean absolute RI error was 2.8° ± 2.1°, and the mean absolute RA error was 3.6° ± 2.2°. Postoperative CT measurements were within 5° of the final intraoperative navigation measurements for RI and RA in 86.7% and 70.0% of hips, respectively. Navigation was successfully completed in all 30 hips, with no conversion to a backup technique. Additional bench testing demonstrated reproducible smartwatch reattachment and reduction of time-dependent relative orientation differences following FPP invocation.Conclusions  This study demonstrated the feasibility of integrating a commercially available smartwatch into a pelvic tracking system for THA navigation. The smartwatch-based pelvic tracking platform achieved a preliminary range of cup-positioning accuracy without requiring continuous optical visualization of a pelvic reference marker while utilizing a compact and widely available consumer wearable device. This study represents the first step toward wearable-device-based navigation in arthroplasty.
SN  - 2524-7948
ER  -