YOLO11m-Based Artificial Intelligence Versus Orthopaedic Physician Panels for Arthroscopy-Referenced Three-Category MRI Classification of the Posterosuperior Rotator Cuff: A Multi-Reader Diagnostic Accuracy Study
- 1Department of Orthopaedics and Traumatology, Gaziosmanpaşa Hospital, Faculty of Medicine, Istinye University, Istanbul 34245, Türkiye
- 2Department of Orthopaedics and Traumatology, Kanuni Sultan Süleyman Training and Research Hospital, University of Health Sciences, Istanbul 34303, Türkiye; (T.B.S.); (A.T.)
- 3Department of Orthopaedics and Traumatology, Faculty of Medicine, Istanbul Yeni Yüzyıl University, Istanbul 34010, Türkiye
Abstract
Background/Objectives: Artificial intelligence (AI) may support rotator cuff MRI interpretation; however, its performance relative to clinicians at different experience levels remains uncertain. We compared a locked YOLO11m-based model with prespecified orthopaedic physician panels using arthroscopy as the reference standard. Methods: This retrospective single-centre study included a separate 300-patient model-development dataset and an arthroscopy-referenced reader cohort of 258 patients (60 intact cuffs, 86 partial-thickness tears, and 112 full-thickness tears). Twelve blinded physicians were assigned to four three-reader experience panels, and panel diagnoses were defined by a two-of-three majority. Paired accuracy comparisons used exact McNemar tests with Holm adjustment. Results: AI achieved 0.841 overall accuracy (95% CI, 0.792–0.881). The senior-specialist panel had numerically higher accuracy (0.911), but the difference from AI was not statistically significant after adjustment (Holm p = 0.060); the junior-specialist panel also did not differ from AI (0.822; Holm p = 0.649). AI showed higher paired accuracy than the senior-resident (0.729; Holm p = 0.005) and junior-resident panels (0.671; Holm p < 0.001). Partial-thickness tears had the lowest AI sensitivity (0.709). Conclusions: In this restricted-cine, three-category benchmark, AI outperformed both resident panels, whereas neither specialist panel comparison reached the adjusted significance threshold. These findings do not establish equivalence to specialists or benefit from AI-assisted reading.
Related
- Utility of Generative Artificial Intelligence in Orthopaedic Surgery Patient Education Materials: A Scoping Review
- Artificial Intelligence Predicts Failure of Nonoperative Treatment in Degenerative Posterosuperior Rotator Cuff Tears.
- Generative Artificial Intelligence in Periodontology: Application of OpenAI Models for the Classification of Periodontitis and Risk Assessment in Patients Undergoing Supportive Periodontal Care
- Artificial Intelligence–Based Classification of Mandibular Condylar Position Using Cone-Beam Computed Tomography: A Single-Center Internal Evaluation
- Artificial Intelligence and Anatomical Variation: A Narrative Review of Detection, Classification, and Educational Applications.
BibTeX
@article{buyukdogan2026yolo11mbased,
title = {{YOLO11m-Based Artificial Intelligence Versus Orthopaedic Physician Panels for Arthroscopy-Referenced Three-Category MRI Classification of the Posterosuperior Rotator Cuff: A Multi-Reader Diagnostic Accuracy Study}},
author = {Halil Büyükdoğan and Tahir Burak Sarıtaş and Avni Tan and Abdülkadir Yalçınkaya and Erhan Abay and Muhammed Halit Yücel and Volkan Arıcı and Necati Doğan and Adem Şahin and Cemil Ertürk},
journal = {Diagnostics},
year = {2026},
month = oct,
doi = {10.3390/diagnostics16213535},
url = {https://doi.org/10.3390/diagnostics16213535},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - YOLO11m-Based Artificial Intelligence Versus Orthopaedic Physician Panels for Arthroscopy-Referenced Three-Category MRI Classification of the Posterosuperior Rotator Cuff: A Multi-Reader Diagnostic Accuracy Study
AU - Halil Büyükdoğan
AU - Tahir Burak Sarıtaş
AU - Avni Tan
AU - Abdülkadir Yalçınkaya
AU - Erhan Abay
AU - Muhammed Halit Yücel
AU - Volkan Arıcı
AU - Necati Doğan
AU - Adem Şahin
AU - Cemil Ertürk
PY - 2026
DA - 2026/10/28
JO - Diagnostics
DO - 10.3390/diagnostics16213535
UR - https://doi.org/10.3390/diagnostics16213535
AB - Background/Objectives: Artificial intelligence (AI) may support rotator cuff MRI interpretation; however, its performance relative to clinicians at different experience levels remains uncertain. We compared a locked YOLO11m-based model with prespecified orthopaedic physician panels using arthroscopy as the reference standard. Methods: This retrospective single-centre study included a separate 300-patient model-development dataset and an arthroscopy-referenced reader cohort of 258 patients (60 intact cuffs, 86 partial-thickness tears, and 112 full-thickness tears). Twelve blinded physicians were assigned to four three-reader experience panels, and panel diagnoses were defined by a two-of-three majority. Paired accuracy comparisons used exact McNemar tests with Holm adjustment. Results: AI achieved 0.841 overall accuracy (95% CI, 0.792–0.881). The senior-specialist panel had numerically higher accuracy (0.911), but the difference from AI was not statistically significant after adjustment (Holm p = 0.060); the junior-specialist panel also did not differ from AI (0.822; Holm p = 0.649). AI showed higher paired accuracy than the senior-resident (0.729; Holm p = 0.005) and junior-resident panels (0.671; Holm p < 0.001). Partial-thickness tears had the lowest AI sensitivity (0.709). Conclusions: In this restricted-cine, three-category benchmark, AI outperformed both resident panels, whereas neither specialist panel comparison reached the adjusted significance threshold. These findings do not establish equivalence to specialists or benefit from AI-assisted reading.
SN - 2075-4418
ER -