Optimizing Avian Influenza Viral RNA Enrichment from Water: A Comparison of Concentration Methods for Low-Volume Samples
- 1Friedrich-Loeffler-Institut
Abstract
Feed-baited water bins may provide a complementary approach for avian influenza virus (AIV) surveillance in wild waterbird populations. In a previous study, water from these bins was sampled using swabs after exposure to visiting birds, but the low sample volume limited the detection and subsequent characterization of AIV RNA (F. I. Rondi, J. Neumann-Heise, T. Harder, V. Allendorf, K. Depner, T. Homeier-Bachmann, L. Breuer, S. Knauf, S. Dreyer, and A. Globig, One Health 23:101548, 2026, https://doi.org/10.1016/j.onehlt.2026.101548). Here, we compared five sample-processing methods for improving AIV RNA detection in small (40-mL) water samples (tap and brackish water) spiked with an AIV of the H4N6 subtype under simulated field conditions: swab sampling, polyethylene glycol precipitation, activated carbon capture, combined activated carbon capture and polyethylene glycol precipitation (AC/PEG), and electronegative membrane adsorption (EM). AC/PEG and EM showed the strongest overall performance based on RT-qPCR results, although their relative performance varied across experimental conditions. The qPCR-derived viral signal was generally higher in tap water than in brackish water, whereas wheat presence was associated with a lower signal, particularly for swab sampling. Subsequent testing was conducted to ascertain the most effective storage conditions with regard to temperature and duration. During storage, AIV RNA detection remained relatively stable at minus 20 degrees Celsius for up to four weeks, with only minor increases in mean Ct values in both water matrices. Greater increases were observed at room temperature and 4 degrees Celsius, with significantly higher Ct values at both temperatures than at minus 20 degrees Celsius in both water matrices at Weeks 2 and 4 (p < 0.05). These findings support the potential of AC/PEG and EM to facilitate the recovery, detection and subsequent characterization of AIV from low-volume water samples by improving viral RNA detection using RT-qPCR. Given its overall performance and lower cost compared with EM, AC/PEG may represent a practical option for field-based surveillance. Regarding storage, minus 20 degrees Celsius provided the best conditions for maintaining AIV RNA detection, with relatively stable results for up to four weeks.
Related
- Optimizing bacterial enrichment procedures to improve mosquito midgut microbiome research
- Performance comparison of probe-capture enrichment sequencing of viruses in wastewater influent and settled solids from the California Central Valley
- Slower growth, indoor environmental enrichment, or covered veranda access: A comparison of three rearing systems for broiler chicken welfare and behavior
- Optimizing genomic selection: A comparison of SNP selection strategies for reduced-density panels in beef cattle
- Comparative evaluation of sample preparation and enrichment methods for culture and molecular detection of Burkholderia pseudomallei in naturally contaminated soils from Thailand over one year.
BibTeX
@misc{heise2026optimizing,
title = {{Optimizing Avian Influenza Viral RNA Enrichment from Water: A Comparison of Concentration Methods for Low-Volume Samples}},
author = {J. Neumann Heise and C. Holzer and C. Stange and A. Thiem and A. Perlas and L. Urban and T. C. Harder and L. Breuer and S. Knauf and A. Globig},
howpublished = {bioRxiv},
year = {2026},
month = nov,
doi = {10.64898/2026.11.13.766378},
url = {https://www.biorxiv.org/content/10.64898/2026.11.13.766378v1},
note = {CC BY-NC},
}
RIS
TY - UNPB
TI - Optimizing Avian Influenza Viral RNA Enrichment from Water: A Comparison of Concentration Methods for Low-Volume Samples
AU - J. Neumann Heise
AU - C. Holzer
AU - C. Stange
AU - A. Thiem
AU - A. Perlas
AU - L. Urban
AU - T. C. Harder
AU - L. Breuer
AU - S. Knauf
AU - A. Globig
PY - 2026
DA - 2026/11/13
PB - bioRxiv
DO - 10.64898/2026.11.13.766378
UR - https://www.biorxiv.org/content/10.64898/2026.11.13.766378v1
AB - Feed-baited water bins may provide a complementary approach for avian influenza virus (AIV) surveillance in wild waterbird populations. In a previous study, water from these bins was sampled using swabs after exposure to visiting birds, but the low sample volume limited the detection and subsequent characterization of AIV RNA (F. I. Rondi, J. Neumann-Heise, T. Harder, V. Allendorf, K. Depner, T. Homeier-Bachmann, L. Breuer, S. Knauf, S. Dreyer, and A. Globig, One Health 23:101548, 2026, https://doi.org/10.1016/j.onehlt.2026.101548). Here, we compared five sample-processing methods for improving AIV RNA detection in small (40-mL) water samples (tap and brackish water) spiked with an AIV of the H4N6 subtype under simulated field conditions: swab sampling, polyethylene glycol precipitation, activated carbon capture, combined activated carbon capture and polyethylene glycol precipitation (AC/PEG), and electronegative membrane adsorption (EM). AC/PEG and EM showed the strongest overall performance based on RT-qPCR results, although their relative performance varied across experimental conditions. The qPCR-derived viral signal was generally higher in tap water than in brackish water, whereas wheat presence was associated with a lower signal, particularly for swab sampling. Subsequent testing was conducted to ascertain the most effective storage conditions with regard to temperature and duration. During storage, AIV RNA detection remained relatively stable at minus 20 degrees Celsius for up to four weeks, with only minor increases in mean Ct values in both water matrices. Greater increases were observed at room temperature and 4 degrees Celsius, with significantly higher Ct values at both temperatures than at minus 20 degrees Celsius in both water matrices at Weeks 2 and 4 (p < 0.05). These findings support the potential of AC/PEG and EM to facilitate the recovery, detection and subsequent characterization of AIV from low-volume water samples by improving viral RNA detection using RT-qPCR. Given its overall performance and lower cost compared with EM, AC/PEG may represent a practical option for field-based surveillance. Regarding storage, minus 20 degrees Celsius provided the best conditions for maintaining AIV RNA detection, with relatively stable results for up to four weeks.
ER -