Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 2 min ago
Peer-reviewedCC BYDesalination and Water Treatment

Extended thermal and microbiological evaluation of an IoT-enabled PID-controlled portable incubator for field-based microbial water-quality testing

6 affiliations
  1. 1Department of Robotics Engineering, Karunya Institute of Technology and Sciences, Coimbatore, Tamil Nadu, 641114, India
  2. 2Department of Electrical and Electronics Engineering, Mar Baselios College of Engineering and Technology, Thiruvananthapuram, Kerala 695015, India
  3. 3Division of Data Science and Cyber Security ,Karunya Institute of Technology and Sciences, Coimbatore, Tamil Nadu, 641114, India
  4. 4Department of Electronics and Communication Engineering, Sir M Visvesvaraya Institute of Technology, Krishnadevaraya Nagar, Hunasamaranahalli, International Airport Road, Bangalore 562157, India
  5. 5Centre for Advanced Robotics, CoE for Robotics and Sensing Technology, Faculty of Artificial Intelligence and Engineering, Multimedia University, Persiaran Multimedia, Cyberjaya, Selangor 63100, Malaysia; Corresponding author.
  6. 6Department of Computer Science and Engineering, Nandha Engineering College, Erode, Tamil Nadu 638052, India

Abstract

This work introduces a low-cost, IoT-enabled, fixed-gain PID-controlled portable microbial incubator for field-based water-quality testing. The prototype uses an ESP32 microcontroller, a central DHT22 sensor, a 50 W positive temperature coefficient heater, a circulation fan, and Bluetooth Low Energy/Wi-Fi for remote temperature monitoring and data logging. A rechargeable 12 V battery or 220 V AC adaptor powers the system. 65 ambient temperature testsassessed the thermal performance from 10 to 40 °C. With a temporal standard deviation of 0.18 °C, a rise time of 4.2 min, and a settling time of 8.7 min, the central control sensor kept the temperature close to 37 °C. The measured standard deviation does not represent absolute measurement precision or chamber-wide spatial uniformity because the sensor was not calibrated against a traceable reference or multi-point thermal mapped. When ambient temperature exceeds the incubation setpoint, the heater-only cannot actively cool the chamber. A preliminary paired study of 16 ambient water samples using 3 M™ Petrifilm™ found no significant differences in Escherichia coli or total-coliform counts between portable and reference incubators (p > 0.05). However, the small sample size and lack of an equivalence margin prevent formal equivalence. The findings suggest decentralised culture-based water testing is feasible, but calibrated multi-point heat measurements, larger microbiological datasets, and experimental battery-discharge validation are considered in future work.

Related

  1. Extended evaluation of activated carbon-embedded glucomannan membranes for the adsorption of structurally and charge-distinct dyes.
    Masahide Hagiri, Taisei Igari, Keita Kashima
    BMC research notesPeer-reviewedCC BY-NC-NDFull textHydrology & soilsEurope PMCDOAJ
  2. Application of a Halophilic Consortium for Saline Phenol Wastewater Treatment and Bioelectricity Generation in Microbial Fuel Cells: An AI-Driven Evaluation.
    Rawan Mohammed Alarishi, Arulazhagan Pugazhendi, Dinesh Kumar Mathew +4
    Biotech (Basel (Switzerland))Peer-reviewedCC BYFull textEnvironmental science & pollutionEurope PMC
  3. Microbiological Quality and Analysis of Escherichia coli Resistance to Antibiotics in Beaches: Evaluating Anthropic Influence in Surface Waters in Brazil.
    Monica M Elias, Francini Dos R Henrique, Philipe R Gomes +6
    Water environment research : a research publication of the Water Environment FederationPeer-reviewedCC BYFull textEnvironmental science & pollutionEurope PMCPMC
  4. Microbiological drinking water quality at source and consumption in Indonesia: An analysis of the national drinking water quality study
    Heru Prasetyo, D. Daniel
    Cleaner WaterPeer-reviewedCC BYFull textHydrology & soilsDOAJ
  5. Revisiting the Signal‐to‐Noise Paradox in Climate Predictions: An Extended Mathematical Framework
    Yuhei Takaya, Adam A. Scaife, Doug Smith +2
    Geophysical Research LettersPeer-reviewedCC BYFull textClimate scienceDOAJ
BibTeX
@article{albert2026extended,
  title = {{Extended thermal and microbiological evaluation of an IoT-enabled PID-controlled portable incubator for field-based microbial water-quality testing}},
  author = {Johny Renoald Albert and Dishore Shunmugham Vanaja and Jamuna R and Senthilkumar P and Sami Salama Hussen Hajjaj and Thiruvenkatasuresh M P},
  journal = {Desalination and Water Treatment},
  year = {2026},
  month = oct,
  doi = {10.1016/j.dwt.2026.102025},
  url = {https://doi.org/10.1016/j.dwt.2026.102025},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Extended thermal and microbiological evaluation of an IoT-enabled PID-controlled portable incubator for field-based microbial water-quality testing
AU  - Johny Renoald Albert
AU  - Dishore Shunmugham Vanaja
AU  - Jamuna R
AU  - Senthilkumar P
AU  - Sami Salama Hussen Hajjaj
AU  - Thiruvenkatasuresh M P
PY  - 2026
DA  - 2026/10/01
JO  - Desalination and Water Treatment
DO  - 10.1016/j.dwt.2026.102025
UR  - https://doi.org/10.1016/j.dwt.2026.102025
AB  - This work introduces a low-cost, IoT-enabled, fixed-gain PID-controlled portable microbial incubator for field-based water-quality testing. The prototype uses an ESP32 microcontroller, a central DHT22 sensor, a 50 W positive temperature coefficient heater, a circulation fan, and Bluetooth Low Energy/Wi-Fi for remote temperature monitoring and data logging. A rechargeable 12 V battery or 220 V AC adaptor powers the system. 65 ambient temperature testsassessed the thermal performance from 10 to 40 °C. With a temporal standard deviation of 0.18 °C, a rise time of 4.2 min, and a settling time of 8.7 min, the central control sensor kept the temperature close to 37 °C. The measured standard deviation does not represent absolute measurement precision or chamber-wide spatial uniformity because the sensor was not calibrated against a traceable reference or multi-point thermal mapped. When ambient temperature exceeds the incubation setpoint, the heater-only cannot actively cool the chamber. A preliminary paired study of 16 ambient water samples using 3 M™ Petrifilm™ found no significant differences in Escherichia coli or total-coliform counts between portable and reference incubators (p > 0.05). However, the small sample size and lack of an equivalence margin prevent formal equivalence. The findings suggest decentralised culture-based water testing is feasible, but calibrated multi-point heat measurements, larger microbiological datasets, and experimental battery-discharge validation are considered in future work.
SN  - 1944-3986
SN  - 1944-3994
ER  -