Skip to content
DraconiticResearch
Search Sources API
190,869 studies31 sourcesUpdated 22 min ago
Peer-reviewedCC BYEnvironmental Health Insights

An Exploratory Comparison of Indoor Air Quality and Culturable Airborne Microbial Concentrations Among Hospital Waiting Areas With Different Ventilation Conditions in Northern Thailand

Abstract

Few studies have simultaneously characterized physical, chemical, and culturable biological indoor air quality (IAQ) in hospital waiting areas, particularly in tropical healthcare settings. This exploratory observational environmental monitoring study assessed PM 2.5 , PM 10 , CO 2 , CO, thermal environmental parameters, and culturable airborne bacterial and fungal concentrations in five hospital waiting areas with different ventilation conditions in Northern Thailand. Measurements were conducted over nine sampling days and summarized at the room-day level to account for repeated spatial measurements. Significant overall differences among waiting areas were observed for PM 10 (p = 0.0012), temperature (p = 0.0006), culturable bacteria (p = 0.0050), and culturable fungi (p = 0.0007), whereas PM 2.5 , relative humidity, CO, and CO 2 did not differ significantly at p < 0.01. No pairwise comparison remained significant after Holm adjustment. Descriptively, Room E, the only mechanically ventilated waiting area, generally showed lower PM 10 and culturable bioaerosol concentrations than several naturally ventilated waiting areas; however, these differences cannot be attributed exclusively to ventilation condition because mechanical ventilation was represented by only one room. Neither mixed-effects models (bacteria: p = 0.062; fungi: p = 0.153) nor room/day fixed-effects sensitivity analyses (bacteria: p = 0.542; fungi: p = 0.447) showed significant associations between PM 10 and culturable bacterial or fungal concentrations. These findings demonstrate substantial room-specific heterogeneity in IAQ and provide a site-specific baseline for future multi-site studies and targeted ventilation, filtration, and IAQ management strategies in hospital waiting areas.

Related

  1. Serum Zinc Concentrations and Dietary Zinc Adequacy in Children and Adolescents with Chronic Conditions: An Exploratory Secondary Analysis
    Marlene Fabiola Escobedo-Monge, José Manuel Marugán-Miguelsanz, Joaquín Parodi Román +2
    NutrientsPeer-reviewedCC BYFull textNutritionEurope PMCCrossref
  2. Pilot study of a local exhaust ventilation system to control particle and terpene concentrations during cannabis processing
    Callan Krevanko, Charlotte Beatson, Martin Cohen +2
    Frontiers in Public HealthPeer-reviewedCC BY 4.0Full textEpidemiology & public healthCrossrefDOAJ
  3. Elevation in Plasma p-tau217 Concentrations Among Blood Donors: An Exploratory Cross-Sectional Study
    X. Li, W. Zhang, R. Wang +19
    medRxivPreprintAll rights reservedFull textNeurologymedRxiv
  4. Transport mechanical ventilation during cardiopulmonary resuscitation in out-of-hospital cardiac arrest: an exploratory prehospital pilot study
    Welawat Tienpratarn, Pariyakon Kusolthammarat, Chaiyaporn Yuksen +1
    BMC Emergency MedicinePeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  5. Exploratory Associations of Heart Rate and Running Velocity at Fixed Blood Lactate Concentrations with Sprint and Jump Performance in Male U19 Soccer Players
    Gülşah Sekban, Nedim Malkoç, Pelin Akyol +4
    MetabolitesPeer-reviewedCC BY 4.0Surgery & anaesthesiaCrossref
BibTeX
@article{thanatrakolsri2026exploratory,
  title = {{An Exploratory Comparison of Indoor Air Quality and Culturable Airborne Microbial Concentrations Among Hospital Waiting Areas With Different Ventilation Conditions in Northern Thailand}},
  author = {Pantitcha Thanatrakolsri and Natnicha Tammawong and Sasiticha Arworn and Supawinee Srikam and Katiya Ivanovitch and Saowanee Norkeaw},
  journal = {Environmental Health Insights},
  year = {2026},
  month = nov,
  doi = {10.1177/11786302261505567},
  url = {https://doi.org/10.1177/11786302261505567},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - An Exploratory Comparison of Indoor Air Quality and Culturable Airborne Microbial Concentrations Among Hospital Waiting Areas With Different Ventilation Conditions in Northern Thailand
AU  - Pantitcha Thanatrakolsri
AU  - Natnicha Tammawong
AU  - Sasiticha Arworn
AU  - Supawinee Srikam
AU  - Katiya Ivanovitch
AU  - Saowanee Norkeaw
PY  - 2026
DA  - 2026/11/04
JO  - Environmental Health Insights
DO  - 10.1177/11786302261505567
UR  - https://doi.org/10.1177/11786302261505567
AB  - Few studies have simultaneously characterized physical, chemical, and culturable biological indoor air quality (IAQ) in hospital waiting areas, particularly in tropical healthcare settings. This exploratory observational environmental monitoring study assessed PM 2.5 , PM 10 , CO 2 , CO, thermal environmental parameters, and culturable airborne bacterial and fungal concentrations in five hospital waiting areas with different ventilation conditions in Northern Thailand. Measurements were conducted over nine sampling days and summarized at the room-day level to account for repeated spatial measurements. Significant overall differences among waiting areas were observed for PM 10 (p = 0.0012), temperature (p = 0.0006), culturable bacteria (p = 0.0050), and culturable fungi (p = 0.0007), whereas PM 2.5 , relative humidity, CO, and CO 2 did not differ significantly at p < 0.01. No pairwise comparison remained significant after Holm adjustment. Descriptively, Room E, the only mechanically ventilated waiting area, generally showed lower PM 10 and culturable bioaerosol concentrations than several naturally ventilated waiting areas; however, these differences cannot be attributed exclusively to ventilation condition because mechanical ventilation was represented by only one room. Neither mixed-effects models (bacteria: p = 0.062; fungi: p = 0.153) nor room/day fixed-effects sensitivity analyses (bacteria: p = 0.542; fungi: p = 0.447) showed significant associations between PM 10 and culturable bacterial or fungal concentrations. These findings demonstrate substantial room-specific heterogeneity in IAQ and provide a site-specific baseline for future multi-site studies and targeted ventilation, filtration, and IAQ management strategies in hospital waiting areas.
SN  - 1178-6302
ER  -