AI-Driven CT Analysis for Aortic Disease: A Task-Based Systematic Review of Segmentation, Measurement, and Detection Applications.
5 affiliations
- 1Radiology Unit, Department of Diagnostic Imaging, E.O. Ospedali Galliera, Mura delle Cappuccine 14, 16128 Genoa, Italy.
- 2Department of Experimental Medicine (DIMES), University of Genoa, 16132 Genoa, Italy.
- 3General and Interventional Radiology Unit, AOM-IRCCS Ospedale Policlinico San Martino, 16132 Genoa, Italy.
- 4Department of Surgical and Integrated Diagnostic Sciences (DISC), University of Genoa, 16132 Genoa, Italy.
- 5Vascular and Endovascular Surgery Unit, AOM-IRCCS Ospedale Policlinico San Martino, 16132 Genoa, Italy.
Abstract
Background/Objectives: Computed tomography (CT) and CT angiography (CTA) are central to assessing aortic aneurysm and dissection, but manual segmentation and geometric analysis remain time-consuming and operator-dependent, while evidence on artificial intelligence (AI) is fragmented. This task-based systematic review synthesised AI applications to CT/CTA of the thoracic and abdominal aorta by primary task: segmentation, measurement, or detection and classification. Methods: PubMed/MEDLINE and Europe PMC were searched from 2015 to September 2026 following PRISMA 2020; the protocol was registered retrospectively (INPLASY2026110004). Segmentation and measurement studies were appraised with CLAIM and detection studies with QUADAS-2/QUADAS-AI, and results were synthesised without meta-analysis. Results: Of 118 included studies (42 segmentation, 38 measurement, 38 detection), half were published since 2024. Median Dice similarity coefficient was 0.90 or higher for the outer wall, lumen and true and false lumina, but 0.86 for intraluminal thrombus and 0.63 for false lumen thrombus. Automated maximum diameter showed a median absolute bias of 0.26 mm (95% limits of agreement about ±5 mm). Detection of aortic dissection reached a median AUC of 0.96-0.97, mostly in enriched samples. External validation was reported in 14%, 34% and 55% of segmentation, measurement and detection studies, 33 of 38 detection studies were at high risk of bias, and only two systems were evaluated prospectively. Conclusions: AI supports technical automation of aortic CT/CTA segmentation and measurement and is progressing toward multistructure geometric phenotyping and clinical decision support, but independent multicentre validation, consecutive cohorts and prospective reader-in-the-loop studies are required before clinical integration. Detection/classification tools require independent diagnostic and workflow validation.
Related
- From underdiagnosis to scalable screening: Applications of artificial intelligence for vertebral compression fracture detection – a systematic review and meta-analysis of diagnostic performance
- Diagnostic Performance of Artificial Intelligence for the Detection and Segmentation of Periapical Lesions on Cone-Beam Computed Tomography: A Systematic Review and Meta-Analysis
- Deep Learning for Real-Time Image Interpretation in Arthroscopy: A Systematic Review of Classification, Segmentation, and Detection Tasks
- Machine Learning and Deep Learning for Early Disease Detection Across Modalities: A Comprehensive Review of Methods, Applications, and Clinical Translation
- Deep learning for cardiac CT segmentation for congenital heart disease: A systematic review
BibTeX
@article{paparo2026aidriven,
title = {{AI-Driven CT Analysis for Aortic Disease: A Task-Based Systematic Review of Segmentation, Measurement, and Detection Applications.}},
author = {Francesco Paparo and Nicola Panvini and Enrico Francesco Melani and Marco Magliocco and Giuseppe Cittadini and Lucio Molini and Giovanni Pratesi and Giovanni Spinella},
journal = {Tomography (Ann Arbor, Mich.)},
year = {2026},
month = nov,
doi = {10.3390/tomography12110166},
url = {https://europepmc.org/article/MED/43083656},
note = {CC BY},
}
RIS
TY - JOUR
TI - AI-Driven CT Analysis for Aortic Disease: A Task-Based Systematic Review of Segmentation, Measurement, and Detection Applications.
AU - Francesco Paparo
AU - Nicola Panvini
AU - Enrico Francesco Melani
AU - Marco Magliocco
AU - Giuseppe Cittadini
AU - Lucio Molini
AU - Giovanni Pratesi
AU - Giovanni Spinella
PY - 2026
DA - 2026/11/18
JO - Tomography (Ann Arbor, Mich.)
DO - 10.3390/tomography12110166
UR - https://europepmc.org/article/MED/43083656
AB - Background/Objectives: Computed tomography (CT) and CT angiography (CTA) are central to assessing aortic aneurysm and dissection, but manual segmentation and geometric analysis remain time-consuming and operator-dependent, while evidence on artificial intelligence (AI) is fragmented. This task-based systematic review synthesised AI applications to CT/CTA of the thoracic and abdominal aorta by primary task: segmentation, measurement, or detection and classification. Methods: PubMed/MEDLINE and Europe PMC were searched from 2015 to September 2026 following PRISMA 2020; the protocol was registered retrospectively (INPLASY2026110004). Segmentation and measurement studies were appraised with CLAIM and detection studies with QUADAS-2/QUADAS-AI, and results were synthesised without meta-analysis. Results: Of 118 included studies (42 segmentation, 38 measurement, 38 detection), half were published since 2024. Median Dice similarity coefficient was 0.90 or higher for the outer wall, lumen and true and false lumina, but 0.86 for intraluminal thrombus and 0.63 for false lumen thrombus. Automated maximum diameter showed a median absolute bias of 0.26 mm (95% limits of agreement about ±5 mm). Detection of aortic dissection reached a median AUC of 0.96-0.97, mostly in enriched samples. External validation was reported in 14%, 34% and 55% of segmentation, measurement and detection studies, 33 of 38 detection studies were at high risk of bias, and only two systems were evaluated prospectively. Conclusions: AI supports technical automation of aortic CT/CTA segmentation and measurement and is progressing toward multistructure geometric phenotyping and clinical decision support, but independent multicentre validation, consecutive cohorts and prospective reader-in-the-loop studies are required before clinical integration. Detection/classification tools require independent diagnostic and workflow validation.
SN - 2379-1381
SN - 2379-139X
ER -