A Physiological Optics Characterization of the Bagolini bar for Testing Density of Suppression.
- 1Department of Physics, Faculty of Production ´ Engineering and Materials Technology, Czestochowa University of Technology, Czestochowa, Poland.
- 2Private Post-Secondary Optical School "Oculus" in Czestochowa, Czestochowa, Poland.
- 3Center of Optics, Optometry and Visual Rehabilitation, Piła, Poland.
Abstract
To characterize the spectral and photometric properties of the 16 filters of a commercial Bagolini bar and to determine whether successive filter numbers correspond to a uniform progression of spectral attenuation, illuminance, and interocular contrast. An instrumental spectrophotometric characterization of the 16 filters of a commercial Bagolini bar was performed. Spectral measurements were acquired over the 320-810 nm instrumental range, with the 380-780 nm visible range used for the principal spectral analysis. Spectrophotometric analysis demonstrated non-linear, step-wise changes in the optical properties of successive Bagolini filters. The transmission spectrum peak with increasing filter number shifted from approximately 610 nm to 770 nm. The transmitted light intensity and Weber contrast also exhibited non-uniform, step-wise changes. The 16 filters do not provide a uniformly graded progression of optical attenuation. The measured spectral and photometric transitions provide an optical basis for testable hypotheses concerning non-uniform perceptual responses, but their clinical consequences require psychophysical and clinical validation.
Related
- Physiological and Molecular Characterization of Allyl Isothiocyanate Adaptation in the Formosan Subterranean Termite, Coptotermes formosanus
- Integrated characterization of terminal heat stress resilience in linseed through agronomic, reproductive, and physiological responses
- Age-Dependent Flowering Transition in Cymbidium goeringii: Physiological Characterization and Small RNA Profiling
- The form of density-dependence in host growth impacts parasitoid-driven host suppression
- Genomic and physiological characterization of Neobacillus ammoniipjilus sp. nov. reveals versatile inorganic nitrogen utilization and ammonia-mitigation potential
BibTeX
@article{dospial2026physiological,
title = {{A Physiological Optics Characterization of the Bagolini bar for Testing Density of Suppression.}},
author = {Marcin Jan Dośpiał and Paweł Kazubowski and Marcin W Jarosik},
journal = {Medical devices (Auckland, N.Z.)},
year = {2026},
month = oct,
doi = {10.2147/mder.s637409},
url = {https://europepmc.org/article/MED/42953338},
note = {CC BY-NC},
}
RIS
TY - JOUR
TI - A Physiological Optics Characterization of the Bagolini bar for Testing Density of Suppression.
AU - Marcin Jan Dośpiał
AU - Paweł Kazubowski
AU - Marcin W Jarosik
PY - 2026
DA - 2026/10/23
JO - Medical devices (Auckland, N.Z.)
DO - 10.2147/mder.s637409
UR - https://europepmc.org/article/MED/42953338
AB - To characterize the spectral and photometric properties of the 16 filters of a commercial Bagolini bar and to determine whether successive filter numbers correspond to a uniform progression of spectral attenuation, illuminance, and interocular contrast. An instrumental spectrophotometric characterization of the 16 filters of a commercial Bagolini bar was performed. Spectral measurements were acquired over the 320-810 nm instrumental range, with the 380-780 nm visible range used for the principal spectral analysis. Spectrophotometric analysis demonstrated non-linear, step-wise changes in the optical properties of successive Bagolini filters. The transmission spectrum peak with increasing filter number shifted from approximately 610 nm to 770 nm. The transmitted light intensity and Weber contrast also exhibited non-uniform, step-wise changes. The 16 filters do not provide a uniformly graded progression of optical attenuation. The measured spectral and photometric transitions provide an optical basis for testable hypotheses concerning non-uniform perceptual responses, but their clinical consequences require psychophysical and clinical validation.