Skip to content
DraconiticResearch
Search Sources API
194,226 studies31 sourcesUpdated 4 min ago
PreprintarXiv licencearXiv

Self-verifying time-resolved multicomponent gas analysis from raw sensor signals

Abstract

Gas sensor arrays can estimate the composition of gas mixtures from their response patterns. However, when a sensor is used outside the laboratory, the true gas concentrations are unknown, so there is usually no direct way to determine whether the estimated result is reliable. Here, we develop a physics-constrained neural network that estimates time-varying gas concentrations and reconstructs the corresponding sensor signals at the same time. We tested the method with a twelve-channel membrane-type surface stress sensor array exposed to water-ethanol mixtures whose concentrations changed over time. The model reconstructed the concentration profiles of both components from the raw signals. Artificial offsets and sensitivity changes in one channel were detected from disagreement between the measured and reconstructed signals. Deletion or replacement of part of a measurement record was detected from violations of the sorption and mechanical equations. This approach enables time-resolved multicomponent gas analysis with self-verification from a single measurement.

Related

  1. Trainable, self-verifying variational quantum eigensolver using adiabatic warm starts
    Bojan Žunkovič, Marco Ballarin, Lewis Wright +1
    Physical Review ResearchPeer-reviewedCC BY 4.0Atomic, molecular & optical physicsAPS
  2. AeroProp-X: An Open-Source, Self-Verifying Method-of-Characteristics Toolkit for Edge-Capable Rocket Nozzle Design and Aerothermodynamic Analysis
    Aryuemaan Kumar Chowdhury
    arXivPreprintCC BY 4.0Full textComputational physicsarXiv
  3. Modulating the polarization-resolved second harmonic generation response of a Sulfamic acid multicomponent crystal via amino acid coformer selection
    Suman Bhattacharya, Matthew Gleeson, Marie-Claire Schanne-Klein +5
    HALPreprintCC BY 4.0Full textOrganic chemistryOptics & photonicsHAL
  4. Profiling a Rydberg-Atom Electric Field Sensor for Off-Resonant Detection of Sub-100 MHz RF Signals
    Michael A. Viray, Abby Halasi-Kun, Baran N. Kayim +3
    arXivPreprintCC BY 4.0Full textAtomic, molecular & optical physicsarXiv
  5. Combining physical models with dynamically acquired experimental information for the optimization of multicomponent NASICON fast ionic conductors in a self-driving laboratory
    Bernardus Rendy, Yuxing Fei, Tanjin He +9
    arXivPreprintCC BY 4.0Full textPhysical chemistryCondensed matterarXiv
BibTeX
@misc{zhou2026selfverifying,
  title = {{Self-verifying time-resolved multicomponent gas analysis from raw sensor signals}},
  author = {YingCheng Zhou and Kosuke Minami and Genki Yoshikawa},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.38663},
  eprint = {2609.38663},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.38663},
}
RIS
TY  - UNPB
TI  - Self-verifying time-resolved multicomponent gas analysis from raw sensor signals
AU  - YingCheng Zhou
AU  - Kosuke Minami
AU  - Genki Yoshikawa
PY  - 2026
DA  - 2026/09/29
PB  - arXiv
DO  - 10.48550/arxiv.2609.38663
UR  - https://arxiv.org/abs/2609.38663
AB  - Gas sensor arrays can estimate the composition of gas mixtures from their response patterns. However, when a sensor is used outside the laboratory, the true gas concentrations are unknown, so there is usually no direct way to determine whether the estimated result is reliable. Here, we develop a physics-constrained neural network that estimates time-varying gas concentrations and reconstructs the corresponding sensor signals at the same time. We tested the method with a twelve-channel membrane-type surface stress sensor array exposed to water-ethanol mixtures whose concentrations changed over time. The model reconstructed the concentration profiles of both components from the raw signals. Artificial offsets and sensitivity changes in one channel were detected from disagreement between the measured and reconstructed signals. Deletion or replacement of part of a measurement record was detected from violations of the sorption and mechanical equations. This approach enables time-resolved multicomponent gas analysis with self-verification from a single measurement.
ER  -