Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 19 min ago
Peer-reviewedCC BY-NC-NDLangenbeck's archives of surgery

Safety and efficacy of the "safe needle" technique in single-portal endoscopic carpal tunnel release for carpal tunnel syndrome: a case series report.

6 affiliations
  1. 1Department of Hand Microsurgery and Plastic Reconstructive Surgery, Ningbo No.6 Hospital, Ningbo No.6 Hospital, Ningbo, Zhejiang, China.
  2. 2Ningbo Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Ningbo, Zhejiang, China.
  3. 3Department of Hand Microsurgery and Plastic Reconstructive Surgery, Ningbo No.6 Hospital, Ningbo No.6 Hospital, Ningbo, Zhejiang, China. [email protected].
  4. 4Ningbo Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Ningbo, Zhejiang, China. [email protected].
  5. 5Department of Hand Microsurgery and Plastic Reconstructive Surgery, Ningbo No.6 Hospital, Ningbo No.6 Hospital, Ningbo, Zhejiang, China. [email protected].
  6. 6Ningbo Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Ningbo, Zhejiang, China. [email protected].

Abstract

Objective

To assess the safety of the "Safe Needle" assistive technique for preventing iatrogenic superficial palmar arch (SPA) injury during single‑portal endoscopic carpal tunnel release (SECTR), and to report secondary clinical outcomes.Methods

This single‑center retrospective case series included 100 patients with carpal tunnel syndrome (CTS) who underwent Safe‑Needle‑assisted SECTR from October 2023 to June 2025. The key procedural step was preoperative high‑frequency ultrasound localization of the SPA apex. A sterile 5‑mL syringe needle was percutaneously inserted vertically 1.0 cm proximal to this apex to create a visible and palpable physical barrier as a mechanical stop deep beneath the transverse carpal ligament (TCL). The primary outcome was the incidence of intra‑ or postoperative SPA‑related injury. Secondary outcomes comprised operative time, complication rates, CTS‑6 scores, pillar‑pain Visual Analog Scale (VAS) scores, and patient‑reported satisfaction.Results

Mean follow‑up duration was 13.2 ± 2.8 months. No iatrogenic SPA injuries were observed across the entire cohort (0%). The overall complication rate was 3.0%, including two cases of mild pillar pain resolving spontaneously within 3 months and one case of complex regional pain syndrome (CRPS). No permanent nerve or tendon injuries occurred. Mean operative time per wrist was 16.2 ± 2.5 min. At final follow‑up, median CTS‑6 scores decreased significantly from 15.0 preoperatively to 6.0 (*P* < 0.001), corresponding to an 84.0% clinical recovery rate; mean patient satisfaction was 6.2 ± 0.9 points.Conclusion

The Safe Needle technique establishes a physical barrier to overcome poorly defined distal cutting borders of the TCL within the endoscopic anatomical blind spot. This simple, low‑cost safety adjunct prevents SPA injury without prolonging operative time or increasing medical expenses. It may be recommended for SECTR clinical training and routine practice to improve intraoperative safety.

Related

  1. Efficacy and Safety of Jailed Balloon–Proximal Optimization Technique Versus Jailed Wire Technique for Preventing Side Branch Occlusion During Percutaneous Coronary Intervention of True Non–Left Main Bifurcation Lesions: A Multicenter, Open‐Label, Randomized Controlled Trial
    Chuncheng Gao, Huimiao Dai, Jing Han +12
    Journal of the American Heart AssociationPeer-reviewedLicence not stated1 citedCardiovascular medicineCrossref
  2. Safety and efficacy of extended surveillance intervals following colorectal endoscopic submucosal dissection: an international multicentre study
    Abdulrahman Qatomah, Paul Brouzeng, Daryl Ramai +10
    GutPeer-reviewedLicence not statedFull text1 citedOncologyHAL
  3. Comparative evaluation of the antipyretic and analgesic efficacy and safety of a fast-release paracetamol 650 mg formulation vs. conventional paracetamol formulations in adults with acute febrile or febrile-pain conditions: a multicenter randomized controlled trial
    Susobhan Mondal, S. K. Ashik Ikbal, Sumit Agrawal +11
    Frontiers in pain research (Lausanne, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. The efficacy and safety of endoscopic ultrasound selective variceal devascularization for the treatment of esophagogastric varices: a retrospective cohort study.
    Chengqi Guan, Fan Huang, Hongyuan Shen +5
    BMC gastroenterologyPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMCDOAJ
  5. The ‘Three-Groove and Two-Arc’ technique for modified Thulium laser enucleation of the prostate: a retrospective study on efficacy and safety
    Wenbo Chao, Jiuwen Zhang, Meng Wang +11
    Frontiers in SurgeryPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMCEurope PMC
BibTeX
@article{zhang2026safety,
  title = {{Safety and efficacy of the "safe needle" technique in single-portal endoscopic carpal tunnel release for carpal tunnel syndrome: a case series report.}},
  author = {Chenxi Zhang and Xianting Zhou and Gaoxiang Yu and Luzhe Wu and Shasha Gong and Jiadong Pan and Shanqing Yin and Xin Wang},
  journal = {Langenbeck's archives of surgery},
  year = {2026},
  month = sep,
  doi = {10.1007/s00423-026-04229-6},
  url = {https://europepmc.org/article/MED/43077129},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Safety and efficacy of the "safe needle" technique in single-portal endoscopic carpal tunnel release for carpal tunnel syndrome: a case series report.
AU  - Chenxi Zhang
AU  - Xianting Zhou
AU  - Gaoxiang Yu
AU  - Luzhe Wu
AU  - Shasha Gong
AU  - Jiadong Pan
AU  - Shanqing Yin
AU  - Xin Wang
PY  - 2026
DA  - 2026/09/01
JO  - Langenbeck's archives of surgery
DO  - 10.1007/s00423-026-04229-6
UR  - https://europepmc.org/article/MED/43077129
AB  - Objective  To assess the safety of the "Safe Needle" assistive technique for preventing iatrogenic superficial palmar arch (SPA) injury during single‑portal endoscopic carpal tunnel release (SECTR), and to report secondary clinical outcomes.Methods  This single‑center retrospective case series included 100 patients with carpal tunnel syndrome (CTS) who underwent Safe‑Needle‑assisted SECTR from October 2023 to June 2025. The key procedural step was preoperative high‑frequency ultrasound localization of the SPA apex. A sterile 5‑mL syringe needle was percutaneously inserted vertically 1.0 cm proximal to this apex to create a visible and palpable physical barrier as a mechanical stop deep beneath the transverse carpal ligament (TCL). The primary outcome was the incidence of intra‑ or postoperative SPA‑related injury. Secondary outcomes comprised operative time, complication rates, CTS‑6 scores, pillar‑pain Visual Analog Scale (VAS) scores, and patient‑reported satisfaction.Results  Mean follow‑up duration was 13.2 ± 2.8 months. No iatrogenic SPA injuries were observed across the entire cohort (0%). The overall complication rate was 3.0%, including two cases of mild pillar pain resolving spontaneously within 3 months and one case of complex regional pain syndrome (CRPS). No permanent nerve or tendon injuries occurred. Mean operative time per wrist was 16.2 ± 2.5 min. At final follow‑up, median CTS‑6 scores decreased significantly from 15.0 preoperatively to 6.0 (*P* < 0.001), corresponding to an 84.0% clinical recovery rate; mean patient satisfaction was 6.2 ± 0.9 points.Conclusion  The Safe Needle technique establishes a physical barrier to overcome poorly defined distal cutting borders of the TCL within the endoscopic anatomical blind spot. This simple, low‑cost safety adjunct prevents SPA injury without prolonging operative time or increasing medical expenses. It may be recommended for SECTR clinical training and routine practice to improve intraoperative safety.
SN  - 1435-2443
SN  - 1435-2451
ER  -