Mixed Reality and Augmented Reality in Complex Revision Shoulder Arthroplasty: Head-mounted Displays for Glenoid Baseplate Positioning

7 affiliations
  1. 1Department of Trauma and Orthopaedic, National Health Service Trust, Hereford, United Kingdom.
  2. 2Department of Orthopaedics, ACS Medical College and Hospital, Dr. MGR Educational and Research Institute, Chennai, Tamil Nadu, India.
  3. 3Department of Regenerative Medicine, Agathisha Institute of Stemcell and Regenerative Medicine, Chennai, Tamil Nadu, India.
  4. 4Department of Orthopaedics, Orthopaedic Research Group, Coimbatore, Tamil Nadu, India.
  5. 5Department of Emergency Medicine, National Health Service, England, United Kingdom.
  6. 6Department of Orthopaedics, Faculty of Medicine - Sri Lalithambigai Medical College and Hospital, Dr. MGR Educational and Research Institute, Chennai, Tamil Nadu, India.
  7. 7Central Research Laboratory, Meenakshi Medical College Hospital and Research Institute, Meenakshi Academy of Higher Education and Research, Chennai, Tamil Nadu, India.

Abstract

Introduction: Revision shoulder arthroplasty, when performed in the context of severe glenoid bone loss, is one of the most technically challenging reconstructive upper-limb procedures. Version, inclination, and precision of the glenoid base plate are the main risk factors for implant survivorship in reverse total shoulder arthroplasty. The use of mixed reality (MR) and augmented reality (AR) head-mounted displays (HMDs) has become a promising solution to overcome the ergonomic and line-of-sight constraints of conventional navigation and patient-specific instrumentation (PSI), while connecting the virtual and real worlds of pre-planning and intra-operative execution. Materials and Methods: A systematic narrative literature search was performed on PubMed/MEDLINE, Embase, Cochrane Library and Scopus databases from January 2010 to September 2026, and reference-chain searches were conducted manually. Combinations of terms such as “mixed reality,” “augmented reality,” “head-mounted display,” “HoloLens,” “Magic Leap,” “shoulder arthroplasty,” “glenoid baseplate,” “revision arthroplasty,” “glenoid bone loss,” “navigation,” and “patient-specific instrumentation” were used as search terms. Studies were chosen based on the relevance to AR/MR technology in shoulder surgery, accuracy in glenoid positioning of the component, and revision arthroplasty outcomes. The review follows a framework developed by the Scale for the Assessment of Narrative Review Articles. Results: Eight studies were found to meet the criteria for quantitative accuracy synthesis. Version deviation was always kept within 0.9°–2.5° using AR-HMD, compared to an average of 5.1° freehand and 3.5°–8° with PSI, and an inclination deviation of 0.9°–4.1° was achieved with AR-HMD, whereas 5.1°–17° was obtained freehand and 3.5°–8° was obtained with PSI. The Pixee Medical HMD, navigated AR Shoulder (Medacta), and Stryker Blue MR Guidance were all found to have similar accuracy profiles. MR guidance was demonstrated to be effective in making the performance of experienced and junior surgeons equal in the positioning of glenoid pins. There are a few regulatory clearances for AR for shoulder arthroplasty in the market, primarily in Europe. Conclusion: AR/MR HMDs are clinically proven, ergonomic tools to assist in the positioning of the glenoid baseplate in revision shoulder arthroplasty. Initial results demonstrate that the accuracy achieved with this approach is comparable to the optical navigation method and, with respect to the freehand technique, has better accuracy, while ensuring the democratization of surgical skill, regardless of the experience of the operator. Additional randomized controlled trials with patient-reported outcomes, prospective cost-utility analyses, and regulatory expansion are needed for universal adoption.

Related

  1. Excellent survivorship and improved active shoulder range of motion 5 years post-reverse total shoulder arthroplasty with mini-augmented glenoid baseplate and mini-humeral tray.
    Ryan Krupp, Christopher O'Grady, Brian Werner +3
    Journal of shoulder and elbow arthroplastyPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  2. Glenoid inclination in reverse total shoulder arthroplasty with and without baseplate wedge augmentation: a retrospective comparative study
    Riki D. Wylie, Clement Chan, Jay R. Ebert +1
    Journal of shoulder and elbow arthroplastyPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  3. Late glenosphere–baseplate Morse taper dissociation after reverse total shoulder arthroplasty with a patient-specific Vault Reconstruction System glenoid: a case report
    MiKinze L. Boeder, Jonathan P. Braman, Allison J. Rao +1
    Journal of shoulder and elbow arthroplastyPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCEurope PMCPMC
  4. Morphometry-based design and finite element assessment of primary stability in glenoid baseplate fixation for reverse shoulder arthroplasty for the Indian population.
    Pearline Beulah John, Sharmila Nageswaran
    Frontiers in bioengineering and biotechnologyPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  5. Revision arthroplasty is associated with significantly higher morbidity but not mortality compared with primary shoulder arthroplasty
    Nicholas J Morriss, Jordan H Manning, Omkar N Prabhavalkar +2
    Shoulder & ElbowPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
BibTeX
@article{bharadwaj2026mixed,
  title = {{Mixed Reality and Augmented Reality in Complex Revision Shoulder Arthroplasty: Head-mounted Displays for Glenoid Baseplate Positioning}},
  author = {Sanjeevi Bharadwaj and Naveen Jeyaraman and Subasri Balasubramanian and Aadithya Siddarth Sridhar and Sathish Muthu and Madahan Jeyaraman},
  journal = {Journal of Orthopaedic Case Reports},
  year = {2026},
  month = nov,
  doi = {10.13107/jocr.2026.v16.i11.8556},
  url = {https://doi.org/10.13107/jocr.2026.v16.i11.8556},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Mixed Reality and Augmented Reality in Complex Revision Shoulder Arthroplasty: Head-mounted Displays for Glenoid Baseplate Positioning
AU  - Sanjeevi Bharadwaj
AU  - Naveen Jeyaraman
AU  - Subasri Balasubramanian
AU  - Aadithya Siddarth Sridhar
AU  - Sathish Muthu
AU  - Madahan Jeyaraman
PY  - 2026
DA  - 2026/11/01
JO  - Journal of Orthopaedic Case Reports
DO  - 10.13107/jocr.2026.v16.i11.8556
UR  - https://doi.org/10.13107/jocr.2026.v16.i11.8556
AB  - Introduction: Revision shoulder arthroplasty, when performed in the context of severe glenoid bone loss, is one of the most technically challenging reconstructive upper-limb procedures. Version, inclination, and precision of the glenoid base plate are the main risk factors for implant survivorship in reverse total shoulder arthroplasty. The use of mixed reality (MR) and augmented reality (AR) head-mounted displays (HMDs) has become a promising solution to overcome the ergonomic and line-of-sight constraints of conventional navigation and patient-specific instrumentation (PSI), while connecting the virtual and real worlds of pre-planning and intra-operative execution. Materials and Methods: A systematic narrative literature search was performed on PubMed/MEDLINE, Embase, Cochrane Library and Scopus databases from January 2010 to September 2026, and reference-chain searches were conducted manually. Combinations of terms such as “mixed reality,” “augmented reality,” “head-mounted display,” “HoloLens,” “Magic Leap,” “shoulder arthroplasty,” “glenoid baseplate,” “revision arthroplasty,” “glenoid bone loss,” “navigation,” and “patient-specific instrumentation” were used as search terms. Studies were chosen based on the relevance to AR/MR technology in shoulder surgery, accuracy in glenoid positioning of the component, and revision arthroplasty outcomes. The review follows a framework developed by the Scale for the Assessment of Narrative Review Articles. Results: Eight studies were found to meet the criteria for quantitative accuracy synthesis. Version deviation was always kept within 0.9°–2.5° using AR-HMD, compared to an average of 5.1° freehand and 3.5°–8° with PSI, and an inclination deviation of 0.9°–4.1° was achieved with AR-HMD, whereas 5.1°–17° was obtained freehand and 3.5°–8° was obtained with PSI. The Pixee Medical HMD, navigated AR Shoulder (Medacta), and Stryker Blue MR Guidance were all found to have similar accuracy profiles. MR guidance was demonstrated to be effective in making the performance of experienced and junior surgeons equal in the positioning of glenoid pins. There are a few regulatory clearances for AR for shoulder arthroplasty in the market, primarily in Europe. Conclusion: AR/MR HMDs are clinically proven, ergonomic tools to assist in the positioning of the glenoid baseplate in revision shoulder arthroplasty. Initial results demonstrate that the accuracy achieved with this approach is comparable to the optical navigation method and, with respect to the freehand technique, has better accuracy, while ensuring the democratization of surgical skill, regardless of the experience of the operator. Additional randomized controlled trials with patient-reported outcomes, prospective cost-utility analyses, and regulatory expansion are needed for universal adoption.