Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 13 min ago
PreprintCC BY-NC-NDmedRxiv

Pupil symmetry and Swinging Light Test Performed with VR Headset for Detection of Anisocoria and Relative Afferent Pupillary Defect

  1. 1University Medical Centre Ljubljana

Abstract

PurposePupil examination is a routine examination of patients presenting with ophthalmological or neurological symptoms. Our purpose was to determine the sensitivity of pupillometry using HP Reverb G2 Omnicept virtual reality (VR) headset for detecting anisocoria and relative afferent pupillary defect (RAPD).

MethodsTwenty-nine patients were included; Group I with asymmetric optic neuropathy (N=21) and Group II with suspected pathological anisocoria (N=8); alongside 19 controls. VR pupillometry consisted of Pupil symmetry test and Swinging light test. Pathological thresholds were established using upper limits of controls. Results were compared with routine pupil exam. Correlations with functional ophthalmological test results were analyzed.

ResultsRAPD was detected in 16/21 Group 1 patients using both VR pupillometry and standard exam. Remaining 5 had relative afferent pupillary asymmetry (RAPA) within the control range (0.1-0.2 mm). Significant correlation was found between RAPA/RAPD and inter-eye difference in visual acuity and visual field defect (MD) (R=0.58 and 0.68, p<0.01). All patients with >5,8 dB inter-eye MD difference had RAPD. In Group II, pathological anisocoria (>0.8 mm) was detected using VR pupillometry and 1/8 on standard exam. Qualitative differences in pupillary constriction were observed. In control group anisocoria (0.4-0.8 mm) was detected in 37% (7/19); in all greater in the dark (mean 0.2 mm).

ConclusionIn comparison to conventional exam VR pupillometry matched detection rate of RAPD and surpassed detection rate of pathological anisocoria. Longitudinal data on pupillary constriction characteristics could significantly contribute to patient diagnosis and monitoring in clinical studies as well as understanding physiological variability.

Related

  1. Beyond Ophthalmoplegia: Wernicke Encephalopathy with Anisocoria.
    Yoshihiro Ito, Koji Hayashi, Haruka Kurihara +2
    Reports (MDPI)Peer-reviewedCC BYFull textNeurologyEurope PMC
  2. Histopathological insights into a swinging cardiac calcified amorphous tumor associated with mitral annular calcification: A case report
    Hiroshi Tsuchiya, Hidehito Endo, Sachito Minegishi +3
    Journal of Cardiology CasesPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicinePMC
  3. Terahertz sensor with parity time symmetry for enhanced detection of frozen oral cancer tissues
    Zaky A. Zaky, Ali Hennache, Abinash Panda
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicineCrossrefDOAJ
  4. Estimation method of attentional object using spatial frequency selectivity in pupillary response
    Yuhong Lv, Rumi Hisakata, Hirohiko Kaneko
    PLOS OnePeer-reviewedCC BY 4.0Full text1 citedNeurosciencePhysiologyPLOS
  5. Pupillary signs are associated with subsequent Hirschsprung disease diagnosis and malignant adrenal neoplasm in congenital central hypoventilation syndrome
    Taher K. Eleiwa, Ahmed S. Bayoumy, Jamal O. Azhari +5
    Scientific ReportsPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaCrossrefDOAJ
BibTeX
@misc{strumbelj2026pupil,
  title = {{Pupil symmetry and Swinging Light Test Performed with VR Headset for Detection of Anisocoria and Relative Afferent Pupillary Defect}},
  author = {M. Strumbelj and N. Vidovic Valentincic and A. Fakin},
  howpublished = {medRxiv},
  year = {2026},
  month = sep,
  doi = {10.64898/2026.09.02.26361629},
  url = {https://www.medrxiv.org/content/10.64898/2026.09.02.26361629v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - Pupil symmetry and Swinging Light Test Performed with VR Headset for Detection of Anisocoria and Relative Afferent Pupillary Defect
AU  - M. Strumbelj
AU  - N. Vidovic Valentincic
AU  - A. Fakin
PY  - 2026
DA  - 2026/09/02
PB  - medRxiv
DO  - 10.64898/2026.09.02.26361629
UR  - https://www.medrxiv.org/content/10.64898/2026.09.02.26361629v1
AB  - PurposePupil examination is a routine examination of patients presenting with ophthalmological or neurological symptoms. Our purpose was to determine the sensitivity of pupillometry using HP Reverb G2 Omnicept virtual reality (VR) headset for detecting anisocoria and relative afferent pupillary defect (RAPD).  MethodsTwenty-nine patients were included; Group I with asymmetric optic neuropathy (N=21) and Group II with suspected pathological anisocoria (N=8); alongside 19 controls. VR pupillometry consisted of Pupil symmetry test and Swinging light test. Pathological thresholds were established using upper limits of controls. Results were compared with routine pupil exam. Correlations with functional ophthalmological test results were analyzed.  ResultsRAPD was detected in 16/21 Group 1 patients using both VR pupillometry and standard exam. Remaining 5 had relative afferent pupillary asymmetry (RAPA) within the control range (0.1-0.2 mm). Significant correlation was found between RAPA/RAPD and inter-eye difference in visual acuity and visual field defect (MD) (R=0.58 and 0.68, p<0.01). All patients with >5,8 dB inter-eye MD difference had RAPD. In Group II, pathological anisocoria (>0.8 mm) was detected using VR pupillometry and 1/8 on standard exam. Qualitative differences in pupillary constriction were observed. In control group anisocoria (0.4-0.8 mm) was detected in 37% (7/19); in all greater in the dark (mean 0.2 mm).  ConclusionIn comparison to conventional exam VR pupillometry matched detection rate of RAPD and surpassed detection rate of pathological anisocoria. Longitudinal data on pupillary constriction characteristics could significantly contribute to patient diagnosis and monitoring in clinical studies as well as understanding physiological variability.
ER  -