Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 27 min ago
Peer-reviewedCC BYJCSM Communications

Gait Analysis for Early Sarcopenia Detection: A Systematic Review of Conventional Metrics and AI‐Based Approaches

  1. 1Department of Physical Education and Sport Sciences Islamic Azad University, Central Tehran Branch Tehran Iran
  2. 2Pediatric Neurorehabilitation Research Center, Ergonomics Department, Faculty of Rehabilitation Sciences University of Social Welfare and Rehabilitation Sciences Tehran Iran
  3. 3Departmnet of Artificial Intelligence, Cyberspace and Advanced Technologies Islamic Azad University, Central Tehran Branch Tehran Iran

Abstract

Background Sarcopenia remains underdiagnosed due to limitations in conventional diagnostic tools. Gait analysis, augmented by wearable sensors and artificial intelligence (AI), offers a non‐invasive alternative for identifying early neuromuscular deterioration. Objective This systematic review synthesizes evidence on gait alterations in older adults with sarcopenia to identify the gait biomarkers with the greatest consistency and clinical utility across conventional, sensor‐based and AI‐driven modalities. Methods Following PRISMA guidelines (PROSPERO registered: CRD420261444509), we searched PubMed, Scopus, Web of Science and MEDLINE, whereas Google Scholar was screened specifically for grey literature (inception to 28 May 2026) for studies evaluating gait in older adults (≥ 60 years) with sarcopenia. Results Twenty‐four studies (10 non‐AI and 14 AI‐based) were included. Across non‐AI studies, reduced gait speed and stride length were the most consistent alterations in sarcopenia, alongside reduced lower‐limb joint range of motion, altered plantar pressure/torque metrics and neuromuscular changes; combined gait models achieved AUCs of 0.702–0.763, and shorter stride length with longer double‐support time predicted injurious falls. Among studies reporting classification accuracy, AI‐based models using wearables, video/pose estimation or multimodal data achieved accuracies ranging from 77.16% (using a ResNet‐18 architecture) to 98.32%, alongside AUCs of 0.92–0.96. However, no AI study had a low overall risk of bias, and methodological heterogeneity precluded meta‐analysis, meaning findings were synthesized narratively. Conclusions Sarcopenia is characterized by a distinct, clinically meaningful gait signature, supporting gait analysis as a viable screening tool. Although gait analysis and AI models hold diagnostic potential for sarcopenia, the lack of external validation and methodological flaws preclude immediate clinical use.

Related

  1. Direct anterior versus conventional approaches for hemiarthroplasty in femoral neck fractures: A systematic review and meta-analysis of functional outcomes
    Mosharaf Hossain Sarkar, Shivam Maheshwari, Sunit Vardhan +3
    Journal of Clinical Orthopaedics and TraumaPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  2. A systematic review of the prevalence and diagnostic approaches of respiratory sarcopenia.
    Leonardo Augusto da Costa Teixeira, Luana Aparecida Soares, Maria Fernanda Dos Santos Mourão +5
    Communications medicinePeer-reviewedCC BYFull text1 citedPhysiologyEurope PMCPMC
  3. Comparative Skeletal Stability of Surgery-First Versus Conventional Orthodontics-First Approaches in Skeletal Class III Malocclusion: A Systematic Review and Meta-Analysis
    Junru Li, Junyan Miao, Yunqiao Liu +2
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  4. Artificial Intelligence Approaches for Gastrointestinal Bleeding Detection in Capsule Endoscopy: A Systematic Review and Critical Analysis
    Nasima Mohammad Helal, Jon Zaccary Regala, Mujeeb Rahman
    DiagnosticsPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  5. Sarcopenia in Hospitalized Patients: A Critical Narrative Review of Diagnostic and Nutritional Management Approaches
    Gavriela Voulgaridou, Spyridoula Ioanna Mourtziapi, George Panoutsopoulos +2
    NutrientsPeer-reviewedCC BYFull textNutritionEurope PMC
BibTeX
@article{mehrlatifan2026gait,
  title = {{Gait Analysis for Early Sarcopenia Detection: A Systematic Review of Conventional Metrics and AI‐Based Approaches}},
  author = {Somayeh Mehrlatifan and Farhad Tabatabai Ghomsheh and Majed Dehghani},
  journal = {JCSM Communications},
  year = {2026},
  month = jul,
  doi = {10.1002/rco2.70057},
  url = {https://doi.org/10.1002/rco2.70057},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Gait Analysis for Early Sarcopenia Detection: A Systematic Review of Conventional Metrics and AI‐Based Approaches
AU  - Somayeh Mehrlatifan
AU  - Farhad Tabatabai Ghomsheh
AU  - Majed Dehghani
PY  - 2026
DA  - 2026/07/01
JO  - JCSM Communications
DO  - 10.1002/rco2.70057
UR  - https://doi.org/10.1002/rco2.70057
AB  - Background Sarcopenia remains underdiagnosed due to limitations in conventional diagnostic tools. Gait analysis, augmented by wearable sensors and artificial intelligence (AI), offers a non‐invasive alternative for identifying early neuromuscular deterioration. Objective This systematic review synthesizes evidence on gait alterations in older adults with sarcopenia to identify the gait biomarkers with the greatest consistency and clinical utility across conventional, sensor‐based and AI‐driven modalities. Methods Following PRISMA guidelines (PROSPERO registered: CRD420261444509), we searched PubMed, Scopus, Web of Science and MEDLINE, whereas Google Scholar was screened specifically for grey literature (inception to 28 May 2026) for studies evaluating gait in older adults (≥ 60 years) with sarcopenia. Results Twenty‐four studies (10 non‐AI and 14 AI‐based) were included. Across non‐AI studies, reduced gait speed and stride length were the most consistent alterations in sarcopenia, alongside reduced lower‐limb joint range of motion, altered plantar pressure/torque metrics and neuromuscular changes; combined gait models achieved AUCs of 0.702–0.763, and shorter stride length with longer double‐support time predicted injurious falls. Among studies reporting classification accuracy, AI‐based models using wearables, video/pose estimation or multimodal data achieved accuracies ranging from 77.16% (using a ResNet‐18 architecture) to 98.32%, alongside AUCs of 0.92–0.96. However, no AI study had a low overall risk of bias, and methodological heterogeneity precluded meta‐analysis, meaning findings were synthesized narratively. Conclusions Sarcopenia is characterized by a distinct, clinically meaningful gait signature, supporting gait analysis as a viable screening tool. Although gait analysis and AI models hold diagnostic potential for sarcopenia, the lack of external validation and methodological flaws preclude immediate clinical use.
SN  - 2996-1394
ER  -