Advances in Microfluidic-Enabled Multiplexed Profiling of Exosomal MiRNAs.
- 1Key Laboratory of Artificial Organs and Computational Medicine of Zhejiang Province, Shulan International Medical College, Institute of Translational Medicine, Zhejiang Shuren University, Hangzhou, 310015, China.
- 2Yuhang Institute of Medical Science Innovation and Transformation, Hangzhou 311112, China.
Abstract
Exosomal miRNAs are emerging as attractive liquid-biopsy biomarkers because of their stability, specificity, and association with cancer progression. Microfluidic technologies can improve multiplex exosomal miRNAs analysis by reducing sample consumption, organizing parallel reactions, integrating extracellular-vesicle enrichment and lysis, and enabling on-chip signal decoding. This review critically compares three implementation routes-spatial encoding, bead-based encoding, and in situ detection-with emphasis on the experimentally demonstrated multiplexing level rather than theoretical coding capacity. Representative studies are compared by analyte scope, microfluidic function, target number, limit of detection, sample type, and clinical validation. Studies using total circulating miRNAs, cell or tissue lysates, non-miRNA exosomal cargoes, or in vivo imaging are explicitly identified as technology-transfer examples rather than direct demonstrations of microfluidic multiplex exosomal miRNA profiling. The remaining challenges include harmonized reporting, scalable on-chip sample preparation, robust decoding, and validation in independent clinical cohorts.
Related
- Scalable Multiplexed Electrochemical Aptasensor Enabled by Chitosan for Heavy Metal Ion Detection: Advancing Electrode Functionalization and Reusability
- CRISPR-Scan: Cas13a Mismatch Tolerance Enabled Ultra-Multiplexed Detection of Same-Site Indels in Acute Myeloid Leukemia.
- Plasma exosomal microRNA profiling in diabetic foot ulcers: inflammatory and proliferative stages—an observational study
- Multiplexed embryo profiling links cellular state to zygotic genome activation in single cells.
- Microfluidic Profiling of an Immune Cell‐Associated Extracellular Vesicle Signature for Active Tuberculosis Diagnosis and Treatment Monitoring
BibTeX
@article{han2026advances,
title = {{Advances in Microfluidic-Enabled Multiplexed Profiling of Exosomal MiRNAs.}},
author = {Weiwei Han and Yijie Zhang and Qifei Ma and Shuhua Liu and Ye Zhang and Zheyu Zou and Liyun Shi},
journal = {Biosensors},
year = {2026},
month = nov,
doi = {10.3390/bios16110673},
url = {https://europepmc.org/article/MED/43082568},
note = {CC BY},
}
RIS
TY - JOUR
TI - Advances in Microfluidic-Enabled Multiplexed Profiling of Exosomal MiRNAs.
AU - Weiwei Han
AU - Yijie Zhang
AU - Qifei Ma
AU - Shuhua Liu
AU - Ye Zhang
AU - Zheyu Zou
AU - Liyun Shi
PY - 2026
DA - 2026/11/20
JO - Biosensors
DO - 10.3390/bios16110673
UR - https://europepmc.org/article/MED/43082568
AB - Exosomal miRNAs are emerging as attractive liquid-biopsy biomarkers because of their stability, specificity, and association with cancer progression. Microfluidic technologies can improve multiplex exosomal miRNAs analysis by reducing sample consumption, organizing parallel reactions, integrating extracellular-vesicle enrichment and lysis, and enabling on-chip signal decoding. This review critically compares three implementation routes-spatial encoding, bead-based encoding, and in situ detection-with emphasis on the experimentally demonstrated multiplexing level rather than theoretical coding capacity. Representative studies are compared by analyte scope, microfluidic function, target number, limit of detection, sample type, and clinical validation. Studies using total circulating miRNAs, cell or tissue lysates, non-miRNA exosomal cargoes, or in vivo imaging are explicitly identified as technology-transfer examples rather than direct demonstrations of microfluidic multiplex exosomal miRNA profiling. The remaining challenges include harmonized reporting, scalable on-chip sample preparation, robust decoding, and validation in independent clinical cohorts.
SN - 2079-6374
ER -