Hand hygiene versus continued glove use in simulated nursing care: a crossover study on microbial kinetics and unintended transmission.
6 affiliations
- 1Dr. Gernot Walder-GmbH, Außervillgraten, East Tyrol, Austria.
- 2Institute for Primary Care Medicine, Johannes Kepler University (JKU), Linz, Austria.
- 3Y2L2Science GmbH, Zams, Austria.
- 4Dr. Gernot Walder-GmbH, Außervillgraten, East Tyrol, Austria. [email protected].
- 5Institute for Primary Care Medicine, Johannes Kepler University (JKU), Linz, Austria. [email protected].
- 6Laboratory Dr. Bundschuh, Oberstiftung 59, 4190, Bad Leonfelden, Austria. [email protected].
Abstract
Background
Healthcare workers' (HCWs) hands are primary vectors for pathogen transmission. While non-sterile examination gloves (NSG) are intended to protect against contamination, they are often perceived as a substitute for hand disinfection (HD). This crossover simulation study in student nurses compared the microbial kinetics of once-disinfected bare hands versus continued NSG use and explored unintended Staphylococcus aureus transmission between participants.Methods
Using a crossover design, twenty-five student nurses performed standardised nursing tasks on manikins under both conditions in randomised order: (i) NSG worn continuously for 45 min without change; (ii) HD with an alcohol-based hand rub immediately before tasks (no gloves). Hand-impression cultures were taken at 0, 5, 15, 25, 35 and 45 min, plate-reading after 24 and 48 h. Counts > 100 CFU were capped at 100. Behaviour was video monitored. Group differences were analysed using the Wilcoxon signed-rank test with Bonferroni correction; S. aureus detection (≥ 1 positive timepoint per arm) was compared by McNemar's exact test.Results
In the HD arm, mean CFU increased from 1.7 ± 3.3 (baseline) to 31.8 ± 30.4 at 5 min and then plateauing around 40-45 CFU for 15-45 min. In the NSG arm, CFU progressively accumulated, reaching 76.7 ± 29.1, 77.1 ± 27.7 and 81.0 ± 27.7 at 25, 35 and 45 min, respectively. From 25 min onwards, NSG counts were significantly higher than HD counts (p = 0.0007, 0.0012 and 0.0003; Bonferroni-corrected α = 0.0083). S. aureus (all methicillin-susceptible) was detected in at least one timepoint in 21/25 (84%) NSG-arm participants versus 9/25 (36%) HD-arm participants (McNemar p = 0.0005). Notably, one baseline nasal carrier, following an observed incomplete HD event, contaminated two co-workers via a shared manikin within 5 min, demonstrating HCW-to-HCW spread in the HD arm.Conclusions
Once-disinfected hands rapidly return to a stable resident microbiome level, whereas continued NSG use without glove changing leads to progressive microbial accumulation and substantially higher S. aureus carriage. NSG must not replace HD and require a change interval of 15-20 min, followed by HD after removal. HD must be performed correctly immediately before patient contact.
Related
- Respiratory function monitoring during neonatal resuscitation: a crossover study of high-fidelity simulated bronchopulmonary dysplasia.
- Disaster Risk Governance and Microbial Infection Transmission in Nigeria: Public Administration Implications
- Viscoelastic-Assisted Rescue of Unintended Free Internal Limiting Membrane Flaps During Macular Hole Surgery: A Two-Case Report
- The unintended consequences of outpatient total joint arthroplasty: a rising complication burden and decreasing reimbursement with the patients left behind.
- Unintended consequences of vaginal misoprostol use in a patient with hydatidiform mole : A case report
BibTeX
@article{walder2026hand,
title = {{Hand hygiene versus continued glove use in simulated nursing care: a crossover study on microbial kinetics and unintended transmission.}},
author = {G Walder and R Pörnbacher and L Knabl and P Suntinger and S Obererlacher and K Edrisi Maryan and B Faustini and C Bundschuh},
journal = {Antimicrobial resistance and infection control},
year = {2026},
month = aug,
doi = {10.1186/s13756-026-01801-z},
url = {https://europepmc.org/article/MED/42972601},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Hand hygiene versus continued glove use in simulated nursing care: a crossover study on microbial kinetics and unintended transmission.
AU - G Walder
AU - R Pörnbacher
AU - L Knabl
AU - P Suntinger
AU - S Obererlacher
AU - K Edrisi Maryan
AU - B Faustini
AU - C Bundschuh
PY - 2026
DA - 2026/08/05
JO - Antimicrobial resistance and infection control
DO - 10.1186/s13756-026-01801-z
UR - https://europepmc.org/article/MED/42972601
AB - Background Healthcare workers' (HCWs) hands are primary vectors for pathogen transmission. While non-sterile examination gloves (NSG) are intended to protect against contamination, they are often perceived as a substitute for hand disinfection (HD). This crossover simulation study in student nurses compared the microbial kinetics of once-disinfected bare hands versus continued NSG use and explored unintended Staphylococcus aureus transmission between participants.Methods Using a crossover design, twenty-five student nurses performed standardised nursing tasks on manikins under both conditions in randomised order: (i) NSG worn continuously for 45 min without change; (ii) HD with an alcohol-based hand rub immediately before tasks (no gloves). Hand-impression cultures were taken at 0, 5, 15, 25, 35 and 45 min, plate-reading after 24 and 48 h. Counts > 100 CFU were capped at 100. Behaviour was video monitored. Group differences were analysed using the Wilcoxon signed-rank test with Bonferroni correction; S. aureus detection (≥ 1 positive timepoint per arm) was compared by McNemar's exact test.Results In the HD arm, mean CFU increased from 1.7 ± 3.3 (baseline) to 31.8 ± 30.4 at 5 min and then plateauing around 40-45 CFU for 15-45 min. In the NSG arm, CFU progressively accumulated, reaching 76.7 ± 29.1, 77.1 ± 27.7 and 81.0 ± 27.7 at 25, 35 and 45 min, respectively. From 25 min onwards, NSG counts were significantly higher than HD counts (p = 0.0007, 0.0012 and 0.0003; Bonferroni-corrected α = 0.0083). S. aureus (all methicillin-susceptible) was detected in at least one timepoint in 21/25 (84%) NSG-arm participants versus 9/25 (36%) HD-arm participants (McNemar p = 0.0005). Notably, one baseline nasal carrier, following an observed incomplete HD event, contaminated two co-workers via a shared manikin within 5 min, demonstrating HCW-to-HCW spread in the HD arm.Conclusions Once-disinfected hands rapidly return to a stable resident microbiome level, whereas continued NSG use without glove changing leads to progressive microbial accumulation and substantially higher S. aureus carriage. NSG must not replace HD and require a change interval of 15-20 min, followed by HD after removal. HD must be performed correctly immediately before patient contact.
SN - 2047-2994
ER -