A multimodal paired slit-lamp photography and anterior segment optical coherence tomography dataset for anterior chamber biometry and cross-modality modelling.

6 affiliations
  1. 1Glaucoma Service, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran.
  2. 2Students Research Committee (SRC), Qazvin University of Medical Sciences, Qazvin, Iran.
  3. 3Department of Engineering, Durham University, South Road, Durham, UK.
  4. 4Institute of Ophthalmology, University College London, London, UK.
  5. 5NIHR Biomedical Research Centre at Moorfields Eye Hospital NHS Foundation Trust, London, UK.
  6. 6Glaucoma Service, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran. [email protected].

Abstract

We describe a multimodal ophthalmic dataset comprising paired slit-lamp photographs, anterior segment optical coherence tomography (AS-OCT) images, and linked eye-level clinical and biometric measurements collected at a single tertiary eye hospital. The release contains 286 de-identified participants and 562 eye-level records, including 15,582 slit-lamp photographs and 9,092 AS-OCT images. Openly downloadable resources include de-identified tabular data, a data dictionary, and documentation, whereas imaging files are distributed through a separate controlled-access Zenodo record because ocular images may retain residual re-identification risk. Records are linked across modalities using non-meaningful patient_id and eye identifiers. We provide dataset-level descriptive statistics, repository structure, de-identification procedures, and quality-control checks, together with a compact baseline experiment showing that paired slit-lamp and AS-OCT records contain usable cross-modal signal for anterior chamber depth prediction. This resource is intended to support reproducible benchmarking, cross-modality modelling, and secondary research use under transparent access governance and versioned release practices.

Related

  1. Application of a multimodal model integrating optical coherence tomography angiography (OCTA) and radiomics for the identification of high-risk Nonarteritic anterior ischaemic optic neuropathy (NAION) populations and for distinguishing its acute phase.
    Peixian Yang, Songlin Cui, Yuxin Zhang +6
    BMC ophthalmologyPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMCPMC
  2. Retained lens fragments obscured by bullous keratopathy: Anterior segment optical coherence tomography before and after endothelial keratoplasty
    American journal of ophthalmology case reportsPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Comparison of Biometric Measurements Between Anterior Segment Hyperparallel and Swept-Source Optical Coherence Tomography
    Andrea Servillo, Natalia Porporato, Bingyao Tan +8
    Translational vision science & technologyPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  4. A deep multimodal model for age-related macular degeneration detection using optical coherence tomography imaging and clinical text data
    M. Fang, H. Miri, K. Bishop +6
    medRxivPreprintAll rights reservedFull textGeneral medicinemedRxiv
  5. Total Corneal Aberration Measurements by Anterior Segment Optical Coherence Tomography and Scheimpflug-Based Imaging: A Narrative Review of Optical Principles and Sources of Inter-Device Discordance
    Doyeon Kim, Seung Pil Bang
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Full textMedical imaging & radiologyCrossrefEurope PMC
BibTeX
@article{tabatabaei2026multimodal,
  title = {{A multimodal paired slit-lamp photography and anterior segment optical coherence tomography dataset for anterior chamber biometry and cross-modality modelling.}},
  author = {Seyed Mehdi Tabatabaei and Alireza Hayati and Mona Safizadeh and Zakieh Vahedian and Amin Ahmadi and Roya Arian and Pearse A Keane and Fereshteh Tayebi},
  journal = {Scientific data},
  year = {2026},
  month = aug,
  doi = {10.1038/s41597-026-07992-9},
  url = {https://europepmc.org/article/MED/43052314},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - A multimodal paired slit-lamp photography and anterior segment optical coherence tomography dataset for anterior chamber biometry and cross-modality modelling.
AU  - Seyed Mehdi Tabatabaei
AU  - Alireza Hayati
AU  - Mona Safizadeh
AU  - Zakieh Vahedian
AU  - Amin Ahmadi
AU  - Roya Arian
AU  - Pearse A Keane
AU  - Fereshteh Tayebi
PY  - 2026
DA  - 2026/08/01
JO  - Scientific data
DO  - 10.1038/s41597-026-07992-9
UR  - https://europepmc.org/article/MED/43052314
AB  - We describe a multimodal ophthalmic dataset comprising paired slit-lamp photographs, anterior segment optical coherence tomography (AS-OCT) images, and linked eye-level clinical and biometric measurements collected at a single tertiary eye hospital. The release contains 286 de-identified participants and 562 eye-level records, including 15,582 slit-lamp photographs and 9,092 AS-OCT images. Openly downloadable resources include de-identified tabular data, a data dictionary, and documentation, whereas imaging files are distributed through a separate controlled-access Zenodo record because ocular images may retain residual re-identification risk. Records are linked across modalities using non-meaningful patient_id and eye identifiers. We provide dataset-level descriptive statistics, repository structure, de-identification procedures, and quality-control checks, together with a compact baseline experiment showing that paired slit-lamp and AS-OCT records contain usable cross-modal signal for anterior chamber depth prediction. This resource is intended to support reproducible benchmarking, cross-modality modelling, and secondary research use under transparent access governance and versioned release practices.
SN  - 2052-4463
ER  -