Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 4 min ago
Peer-reviewedCC BY 4.0Journal of Clinical Medicine

Total Corneal Aberration Measurements by Anterior Segment Optical Coherence Tomography and Scheimpflug-Based Imaging: A Narrative Review of Optical Principles and Sources of Inter-Device Discordance

  1. 1Department of Medicine, Keimyung University School of Medicine, Daegu 42601, Republic of Korea
  2. 2Department of Ophthalmology, Keimyung University School of Medicine, Daegu 42601, Republic of Korea

Abstract

Total corneal aberration analysis is increasingly used as part of intraocular lens selection, ectasia screening, and refractive surgery planning. Scheimpflug-based tomography and anterior segment optical coherence tomography (AS-OCT) are commonly used imaging techniques to identify the anterior and posterior corneal surfaces; however, many devices combine these methods with Placido-disc topography or reconstruction algorithms. Although these devices provide anterior, posterior, and total corneal wavefront aberrations, multiple studies have shown that Zernike coefficients obtained with different systems are not consistently interchangeable, particularly for posterior-surface-derived and higher-order terms such as trefoil and total higher-order aberration root-mean-square values. This narrative review summarizes the optical principles of Scheimpflug imaging and AS-OCT, synthesizes the available comparative literature, and analyzes the mechanisms that may contribute to inter-device discordance, including differences in light sources and light-tissue interactions, posterior-surface reconstruction and refractive-index assumptions, edge-detection and Zernike-fitting algorithms, sampling geometry and acquisition time, and reference-axis selection. We discuss the clinical implications of these discrepancies and propose a research agenda, including model-eye validation and ray-tracing simulation studies, to help distinguish the effects of hardware optics from those of proprietary reconstruction algorithms.

Related

  1. Discordance Between Gated Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging and Coronary Angiography in Dilated Cardiomyopathy
    Anowarul Islam, Sabrina Taher, Tanvir Ahmed +7
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Comparison of Biometric Measurements Between Anterior Segment Hyperparallel and Swept-Source Optical Coherence Tomography
    Andrea Servillo, Natalia Porporato, Bingyao Tan +8
    Translational vision science & technologyPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Computed tomography-based measurements of fat quality are associated with the prognostic nutritional index in gastric cancer patients
    Ryohei Nishiguchi, Shinichi Asaka, Masano Sagawa +9
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textPhysiologyCrossref
  4. Lung function change and quantitative computed tomography measurements are associated with prospective frailty
    Eleanor Kate Phillips, Elizabeth Regan, Karin F. Hoth +13
    ERJ open researchPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  5. Diagnostic capability of perimetry and optical coherence tomography based retinal thickness measurements in diabetic patients with no or mild retinopathy
    Nasrin Moghadas Sharif, Faezeh Noferesti, Maliheh Karimpour +1
    Photodiagnosis and Photodynamic TherapyPeer-reviewedCC BYFull textGeneral medicineDOAJ
BibTeX
@article{kim2026total,
  title = {{Total Corneal Aberration Measurements by Anterior Segment Optical Coherence Tomography and Scheimpflug-Based Imaging: A Narrative Review of Optical Principles and Sources of Inter-Device Discordance}},
  author = {Doyeon Kim and Seung Pil Bang},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  month = oct,
  doi = {10.3390/jcm15208174},
  url = {https://www.mdpi.com/2077-0383/15/20/8174},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Total Corneal Aberration Measurements by Anterior Segment Optical Coherence Tomography and Scheimpflug-Based Imaging: A Narrative Review of Optical Principles and Sources of Inter-Device Discordance
AU  - Doyeon Kim
AU  - Seung Pil Bang
PY  - 2026
DA  - 2026/10/01
JO  - Journal of Clinical Medicine
DO  - 10.3390/jcm15208174
UR  - https://www.mdpi.com/2077-0383/15/20/8174
AB  - Total corneal aberration analysis is increasingly used as part of intraocular lens selection, ectasia screening, and refractive surgery planning. Scheimpflug-based tomography and anterior segment optical coherence tomography (AS-OCT) are commonly used imaging techniques to identify the anterior and posterior corneal surfaces; however, many devices combine these methods with Placido-disc topography or reconstruction algorithms. Although these devices provide anterior, posterior, and total corneal wavefront aberrations, multiple studies have shown that Zernike coefficients obtained with different systems are not consistently interchangeable, particularly for posterior-surface-derived and higher-order terms such as trefoil and total higher-order aberration root-mean-square values. This narrative review summarizes the optical principles of Scheimpflug imaging and AS-OCT, synthesizes the available comparative literature, and analyzes the mechanisms that may contribute to inter-device discordance, including differences in light sources and light-tissue interactions, posterior-surface reconstruction and refractive-index assumptions, edge-detection and Zernike-fitting algorithms, sampling geometry and acquisition time, and reference-axis selection. We discuss the clinical implications of these discrepancies and propose a research agenda, including model-eye validation and ray-tracing simulation studies, to help distinguish the effects of hardware optics from those of proprietary reconstruction algorithms.
SN  - 2077-0383
ER  -