Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 20 min ago
Peer-reviewedCC BY 4.0Journal of Biomedical Science and Engineering

Numerical Simulation of the Mitral Valve Repair

Abstract

This paper presents a customizable finite element framework of the mitral valve and surrounding structures for the numerical study of transcatheter annuloplasty. The geometry used in this work corresponds to a single reference left-heart model provided by KIT and was preprocessed using CAD tools. The present study focuses on the mechanical response of the valve region during prosthetic ring positioning and annular downsizing. In the complete annuloplasty model, prosthesis positioning and downsizing were completed sequentially in Abaqus. Because severe mesh distortion prevented completion of physiological loading after downsizing in the prosthesis-including model, ventricular contraction and pressure loading were implemented in a separate "Physio" configuration without the prosthesis. The resulting deformation and stress patterns are consistent with previously reported computational trends, with elevated stresses in the atrioventricular-junction region near the fibrous trigones and posterior annular region. The model should therefore be considered a methodological framework and proof of concept, rather than a fully validated patient-specific planning tool. Future work will focus on mesh convergence, experimental validation, and reintegration of physiological loading into the complete annuloplasty model.

INTRODUCTION

Clinical ContextCardiovascular disease remains the leading cause of death worldwide, accounting for 31% of all global deaths. Mitral regurgitation (MR) is the second most prevalent valve disorder in Europe, affecting 2% of the global population [1]. This pathology is characterized by an enlargement of the mitral valve (MV) diameter, which compromises the coaptation of the leaflets during systole. Consequently, a leak in the valve allows retrograde blood flow from the left ventricle into the left atrium. First introduced by Alain Carpentier in Open Access

Related

  1. Outcomes of Surgical Versus Transcatheter Mitral Valve Repair or Replacement in Patients With Myocardial Infarction and Concomitant Mitral Regurgitation: A Retrospective Analysis of Real-World Data
    Judah Rajendran, Akiva Rosenzveig, Nishitha Vempalli +6
    Journal of the Society for Cardiovascular Angiography & InterventionsPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicinePMCEurope PMC
  2. Hospital costs and early outcomes of robotic versus sternotomy mitral valve repair: A risk-score-matched analysis.
    Anh Nguyen, Gabriel Loor, Ravi Ghanta +3
    JTCVS openPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMCPMC
  3. Mitral Transcatheter Edge-to-Edge Repair in a Challenging Anatomy With Deeply Implanted Self-Expanding Valve and Severe Mitral Annular Calcification: A Case Report
    Muhammad Saad, Raviteja Guddeti, Nadia El-Hangouche +1
    Journal of the Society for Cardiovascular Angiography & InterventionsPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicinePMCEurope PMC
  4. Transcatheter Edge-to-Edge Repair for Mitral Valve Systolic Anterior Motion in Complex Left Ventricular Outflow Tract Phenotypes: A Case Series.
    Mark J Zorman, Smitha Narayana Gowda, Ratnasari Padang +3
    Journal of the Society for Cardiovascular Angiography & InterventionsPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  5. Prognostic Impact of Mitral Valve Sphericity Index After Mitral Valve Transcatheter Edge-to-Edge Repair in Functional Mitral Regurgitation
    Takanori Kawamoto, Chihiro Koyanagi, Yuichiro Minami +12
    Circulation JournalPeer-reviewedCC BY-NC-NDFull text1 citedCardiovascular medicineJ-STAGE
BibTeX
@article{pigeon2026numerical,
  title = {{Numerical Simulation of the Mitral Valve Repair}},
  author = {Tévy Julie Pigeon and Pascale Kulisa and Fabrice Morestin and Benyebka Bou-Saïd},
  journal = {Journal of Biomedical Science and Engineering},
  year = {2026},
  month = jun,
  doi = {10.4236/jbise.2026.196019},
  url = {https://hal.science/hal-05843499v1},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Numerical Simulation of the Mitral Valve Repair
AU  - Tévy Julie Pigeon
AU  - Pascale Kulisa
AU  - Fabrice Morestin
AU  - Benyebka Bou-Saïd
PY  - 2026
DA  - 2026/06/25
JO  - Journal of Biomedical Science and Engineering
DO  - 10.4236/jbise.2026.196019
UR  - https://hal.science/hal-05843499v1
AB  - This paper presents a customizable finite element framework of the mitral valve and surrounding structures for the numerical study of transcatheter annuloplasty. The geometry used in this work corresponds to a single reference left-heart model provided by KIT and was preprocessed using CAD tools. The present study focuses on the mechanical response of the valve region during prosthetic ring positioning and annular downsizing. In the complete annuloplasty model, prosthesis positioning and downsizing were completed sequentially in Abaqus. Because severe mesh distortion prevented completion of physiological loading after downsizing in the prosthesis-including model, ventricular contraction and pressure loading were implemented in a separate "Physio" configuration without the prosthesis. The resulting deformation and stress patterns are consistent with previously reported computational trends, with elevated stresses in the atrioventricular-junction region near the fibrous trigones and posterior annular region. The model should therefore be considered a methodological framework and proof of concept, rather than a fully validated patient-specific planning tool. Future work will focus on mesh convergence, experimental validation, and reintegration of physiological loading into the complete annuloplasty model.  INTRODUCTION  Clinical ContextCardiovascular disease remains the leading cause of death worldwide, accounting for 31% of all global deaths. Mitral regurgitation (MR) is the second most prevalent valve disorder in Europe, affecting 2% of the global population [1]. This pathology is characterized by an enlargement of the mitral valve (MV) diameter, which compromises the coaptation of the leaflets during systole. Consequently, a leak in the valve allows retrograde blood flow from the left ventricle into the left atrium. First introduced by Alain Carpentier in Open Access
SN  - 1937-6871
SN  - 1937-688X
ER  -