Fabrication of Pt-decorated MXene–chitosan nanocomposite electrodes for non-enzymatic electrochemical detection of biomolecules
- 1Functional Biomaterials Laboratory, Department of Metallurgical and Materials Engineering, National Institute of Technology Karnataka Surathkal Mangaluru Karnataka 575025 India
- 2Corrosion Engineering Lab, Department of Metallurgical and Materials Engineering, National Institute of Technology Karnataka Surathkal Mangaluru Karnataka 575025 India
Abstract
Cholesterol and hydrogen peroxide (H2O2) are essential biomolecules for maintaining the physical equilibrium, and their abnormal levels cause cancer and several cardiovascular diseases. To address the drawbacks of enzymatic techniques, including poor stability, high fabrication cost, and sensitivity to environmental conditions, a platinum nanoparticle (Pt) anchored MXene–chitosan composite (Pt/MX–Chit) was coated on an ITO substrate to develop a robust non-enzymatic platform. The integration of highly conductive MXene, electrocatalytically active Pt nanoparticles, and a biocompatible, film-forming chitosan matrix enables efficient electron transfer, improves the structural stability, and increases the number of surface-active sites compared to the existing non-enzymatic platforms. The fabricated electrode provides enzyme-free cholesterol detection by the catalytic oxidation of cholesterol and H2O2 by catalytic reduction. The structural characteristics and surface morphology of the synthesized materials were examined by SEM, XRD, TEM, AFM, and FTIR. The developed sensor exhibited a linear response to H2O2 concentration (0–160 µM) with a sensitivity of 1.29 µA µM−1, and an estimated LOD value of 4.57 µM and LOQ of 15.25 µM, which shows the strong catalytic reduction capability of the Pt/MX-Chit composite electrode interface. Non-enzymatic cholesterol detection was also performed with a positive response within the range of 0–20 µM through the oxidation of cholesterol in the anodic oxidation region. The sensor achieved a sensitivity of 14.6 µA µM−1. The estimated LOD and LOQ are 0.30 µM and 1.01 µM, respectively. The fabricated Pt/MX-Chit-ITO electrode offers a cost-effective and fast detection platform for biosensing applications.
Related
- Repeated Laser Exposure Enhances Electrochemical Response in Ag/Laser-Induced Graphene Electrodes with a Hierarchical Assessment of Fabrication Reproducibility
- Engineering graphene oxide interfaces for electrochemical biosensing of biomolecules, cells, and organoids
- Portable and wireless microfluidic impedance sensor functionalized with MnCoPBA@MoS2 nanocomposite screen-printed gold electrodes for on-site bacteria detection
- Graphite Nanosheets Decorated CeO2 Nanocomposite for Enhanced Supercapacitor Applications
- Porphyrin-decorated perylene–nickel-MOF nanocomposite: photoinduced electron and energy transfer for photoelectrochemical applications
BibTeX
@article{sreejisha2026fabrication,
title = {{Fabrication of Pt-decorated MXene–chitosan nanocomposite electrodes for non-enzymatic electrochemical detection of biomolecules}},
author = {Sreejisha N and Silpa Sasikumar and Abhipreet Mohapatra and Kunal Bhalchandra Bhole and Shashi Bhushan Arya and Selvakumar Murugesan},
journal = {RSC Advances},
year = {2026},
month = nov,
doi = {10.1039/d6ra08719a},
url = {https://doi.org/10.1039/d6ra08719a},
note = {CC BY-NC 3.0},
}
RIS
TY - JOUR
TI - Fabrication of Pt-decorated MXene–chitosan nanocomposite electrodes for non-enzymatic electrochemical detection of biomolecules
AU - Sreejisha N
AU - Silpa Sasikumar
AU - Abhipreet Mohapatra
AU - Kunal Bhalchandra Bhole
AU - Shashi Bhushan Arya
AU - Selvakumar Murugesan
PY - 2026
DA - 2026/11/13
JO - RSC Advances
DO - 10.1039/d6ra08719a
UR - https://doi.org/10.1039/d6ra08719a
AB - Cholesterol and hydrogen peroxide (H2O2) are essential biomolecules for maintaining the physical equilibrium, and their abnormal levels cause cancer and several cardiovascular diseases. To address the drawbacks of enzymatic techniques, including poor stability, high fabrication cost, and sensitivity to environmental conditions, a platinum nanoparticle (Pt) anchored MXene–chitosan composite (Pt/MX–Chit) was coated on an ITO substrate to develop a robust non-enzymatic platform. The integration of highly conductive MXene, electrocatalytically active Pt nanoparticles, and a biocompatible, film-forming chitosan matrix enables efficient electron transfer, improves the structural stability, and increases the number of surface-active sites compared to the existing non-enzymatic platforms. The fabricated electrode provides enzyme-free cholesterol detection by the catalytic oxidation of cholesterol and H2O2 by catalytic reduction. The structural characteristics and surface morphology of the synthesized materials were examined by SEM, XRD, TEM, AFM, and FTIR. The developed sensor exhibited a linear response to H2O2 concentration (0–160 µM) with a sensitivity of 1.29 µA µM−1, and an estimated LOD value of 4.57 µM and LOQ of 15.25 µM, which shows the strong catalytic reduction capability of the Pt/MX-Chit composite electrode interface. Non-enzymatic cholesterol detection was also performed with a positive response within the range of 0–20 µM through the oxidation of cholesterol in the anodic oxidation region. The sensor achieved a sensitivity of 14.6 µA µM−1. The estimated LOD and LOQ are 0.30 µM and 1.01 µM, respectively. The fabricated Pt/MX-Chit-ITO electrode offers a cost-effective and fast detection platform for biosensing applications.
SN - 2046-2069
ER -