Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 29 min ago
Peer-reviewedCC BY 4.0BioMed Research International

Development of Polyclonal Anti‐HBsAg IgY Antibodies and Comparative Evaluation of Glutaraldehyde Versus Periodate HRP Bioconjugation for Hepatitis B Diagnosis

  1. 1Faculty of Health Science Université des Montagnes Bangangté Cameroon udesmontagnes.org
  2. 2Laboratory of Pharmacology and Toxicology Department of Biochemistry Faculty of Science University of Yaoundé 1 Yaoundé Cameroon uy1.uninet.cm
  3. 3Department of Biomedical Sciences Faculty of Health Sciences University of Buea Buea Cameroon ubuea.cm

Abstract

Hepatitis B virus remains a major global health burden, particularly in sub‐Saharan Africa, where affordable, specific and locally producible diagnostic tools are urgently needed. Conventional mammalian antibody‐based assays can suffer from high background signals and interference in human sera. We developed a polyclonal chicken IgY reagent against the immunodominant “a” determinant of HBsAg, using consensus peptides to limit immune escape: two 24‐amino‐acid consensus peptides from the major hydrophilic region were synthesised and used to immunise laying hens. Antigen‐specific IgY was extracted from egg yolks by salting‐out precipitation, purified by peptide‐affinity chromatography and conjugated to horseradish peroxidase by glutaraldehyde cross‐linking and by sodium periodate oxidation. SDS‐PAGE under reducing and non‐reducing conditions confirmed the structural integrity of the purified IgY. Both chemistries yielded functional conjugates, but the periodate‐oxidised conjugate gave a significantly higher signal across dilutions (Wilcoxon test, p = 0.016). In an adapted commercial sandwich ELISA applied to 10 HBsAg‐positive and 10 HBsAg‐negative sera, the in‐house IgY–HRP conjugates produced optical density profiles that differed from the commercial biotinylated system (repeated‐measures ANOVA, p < 0.0001) while separating positive from negative sera completely. Receiver‐operating‐characteristic analysis gave an area under the curve of 1.000 for all three detection systems, and at the Youden‐derived cut‐offs (OD450 0.77 for the glutaraldehyde and 0.80 for the periodate conjugate) both in‐house reagents reached 100% sensitivity and 100% specificity (95% CI 72.2%–100% for each, n = 10 per group). This work establishes a low‐cost, locally producible IgY‐based platform for HBsAg detection, offering a scalable alternative for HBV screening in resource‐limited, high‐prevalence settings.

Related

  1. Tumor-antigen-specific polyclonal antibodies suppress tumor growth and metastasis in heterogeneous solid tumors
    Carine Ciron, Ophélie Dauphouy, Pierre Morice +7
    Frontiers in oncologyPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMCCrossref
  2. P18.09.A Development and validation of single-domain antibodies targeting B7-H3 for radioligand therapy in glioblastoma
    D Isci, R Quintens, V Rob +8
    Neuro-OncologyPeer-reviewedPublisher termsFull textMedical imaging & radiologyPMC
  3. Advances in drug development for chronic pain: from traditional drugs to targeted antibodies and small molecules—a narrative review
    Siyuan He, Zhenxi Li
    Frontiers in PharmacologyPeer-reviewedCC BY 4.0Pharmacology & toxicologyCrossrefFrontiers
  4. Clinical characteristics associated with GAD65 antibodies: a comparative study between high and low GAD65-ab cohorts
    Paula Lombardo-Del Toro, Sònia Jaraba, Guillermo Hernández-Pérez +9
    Frontiers in NeurologyPeer-reviewedCC BY 4.0Full textNeurologyCrossrefEurope PMCPMCEurope PMC
  5. Development and Validation of Serological Tests for Avian Influenza Antibodies in Meat Juice From Wild Birds
    Simone Kronborg, Iben Stokholm, Karen Martiny +4
    Influenza and Other Respiratory VirusesPeer-reviewedCC BY-NC 4.0Full textEpidemiology & public healthPMC
BibTeX
@article{tchatchoua2026development,
  title = {{Development of Polyclonal Anti‐HBsAg IgY Antibodies and Comparative Evaluation of Glutaraldehyde Versus Periodate HRP Bioconjugation for Hepatitis B Diagnosis}},
  author = {Felicienne Tchoufang Tchatchoua and Herman Philipe Nfombouot-Njitoyap and Yacouba Foupouapouognigni and Floriane Tekoutsap Manetsop and Arnaud Fondjo Kouam and Frédéric Nico Njayou and Simon Ngamli Fewou and Paul Fewou Moundipa},
  journal = {BioMed Research International},
  year = {2026},
  month = nov,
  doi = {10.1155/bmri/6006257},
  url = {https://doi.org/10.1155/bmri/6006257},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Development of Polyclonal Anti‐HBsAg IgY Antibodies and Comparative Evaluation of Glutaraldehyde Versus Periodate HRP Bioconjugation for Hepatitis B Diagnosis
AU  - Felicienne Tchoufang Tchatchoua
AU  - Herman Philipe Nfombouot-Njitoyap
AU  - Yacouba Foupouapouognigni
AU  - Floriane Tekoutsap Manetsop
AU  - Arnaud Fondjo Kouam
AU  - Frédéric Nico Njayou
AU  - Simon Ngamli Fewou
AU  - Paul Fewou Moundipa
PY  - 2026
DA  - 2026/11/15
JO  - BioMed Research International
DO  - 10.1155/bmri/6006257
UR  - https://doi.org/10.1155/bmri/6006257
AB  - Hepatitis B virus remains a major global health burden, particularly in sub‐Saharan Africa, where affordable, specific and locally producible diagnostic tools are urgently needed. Conventional mammalian antibody‐based assays can suffer from high background signals and interference in human sera. We developed a polyclonal chicken IgY reagent against the immunodominant “a” determinant of HBsAg, using consensus peptides to limit immune escape: two 24‐amino‐acid consensus peptides from the major hydrophilic region were synthesised and used to immunise laying hens. Antigen‐specific IgY was extracted from egg yolks by salting‐out precipitation, purified by peptide‐affinity chromatography and conjugated to horseradish peroxidase by glutaraldehyde cross‐linking and by sodium periodate oxidation. SDS‐PAGE under reducing and non‐reducing conditions confirmed the structural integrity of the purified IgY. Both chemistries yielded functional conjugates, but the periodate‐oxidised conjugate gave a significantly higher signal across dilutions (Wilcoxon test, p = 0.016). In an adapted commercial sandwich ELISA applied to 10 HBsAg‐positive and 10 HBsAg‐negative sera, the in‐house IgY–HRP conjugates produced optical density profiles that differed from the commercial biotinylated system (repeated‐measures ANOVA, p < 0.0001) while separating positive from negative sera completely. Receiver‐operating‐characteristic analysis gave an area under the curve of 1.000 for all three detection systems, and at the Youden‐derived cut‐offs (OD450 0.77 for the glutaraldehyde and 0.80 for the periodate conjugate) both in‐house reagents reached 100% sensitivity and 100% specificity (95% CI 72.2%–100% for each, n = 10 per group). This work establishes a low‐cost, locally producible IgY‐based platform for HBsAg detection, offering a scalable alternative for HBV screening in resource‐limited, high‐prevalence settings.
SN  - 2314-6133
SN  - 2314-6141
ER  -