Pericoronary fat attenuation index and TyG index improve CCTA-based diagnosis of in-stent restenosis: a cross-sectional study
- 1Department of Radiology, TEDA International Cardiovascular Hospital, Tianjin University, Tianjin, China
- 2Department of Radiology, Tianjin Cancer Hospital Airport Hospital, Tianjin, China
Abstract
Objective: This study investigated the associations of the pericoronary fat attenuation index (FAI) and triglyceride–glucose (TyG) index with in-stent restenosis (ISR) in patients with coronary artery disease (CAD) following stent implantation and evaluated the diagnostic value of combining these markers with coronary computed tomography angiography (CCTA).
Methods: A total of 240 patients with previous stent implantation who underwent CCTA and coronary angiography (CAG) within one month were included. Pericoronary FAI was quantified from CCTA images using a semiautomated analysis system, and the TyG index was calculated. Patients were classified into ISR and non-ISR groups according to CAG findings. Clinical and imaging characteristics were compared between the groups. Patient-level associations with ISR were assessed using binary logistic regression, whereas stent-level analyses employed generalized estimating equations (GEE) to account for within-patient clustering. Receiver operating characteristic (ROC) curve analysis was used to evaluate the discriminative performance of CCTA, FAI and the TyG index, individually and in combination.
Results: At the patient level, the ISR group had a higher TyG index (8.83 vs. 8.52, p = 0.006) and higher FAI around the right coronary artery (RCA) (−80.8 vs. −83.4 HU, p = 0.014). At the stent level, pre-stent FAI (−79.1 vs. −81.7 HU, p = 0.025), peri-stent FAI (−82.3 vs. −86.6 HU, p < 0.001), and the TyG index (8.85 vs. 8.58, p = 0.006) were higher in the ISR group. In multivariable GEE analysis, peri-stent FAI (OR = 1.063, p = 0.001) and the TyG index (OR = 1.685, p = 0.009) were independently associated with ISR. The area under the ROC curve (AUC) increased from 0.639 for CCTA alone to 0.734 for CCTA combined with peri-stent FAI and the TyG index ( p < 0.001).
Conclusion: The TyG index and peri-stent FAI were independently associated with ISR. A diagnostic model combining these two markers with CCTA demonstrated better discrimination than CCTA alone.
Related
- Left anterior descending artery pericoronary adipose tissue (PCAT) attenuation independently distinguishes ACS from stable coronary disease, and multivessel coronary CT angiography-PCAT combination improves diagnostic accuracy
- Elevated pericoronary adipose tissue attenuation assessed by fat attenuation index in atrial fibrillation without cardiovascular comorbidities: a retrospective observational study
- Associations of lesion-specific pericoronary adipose tissue attenuation and CT-derived fractional flow reserve with coronary stenosis progression: a retrospective selected-lesion study
- Computed Tomography Angiography-Derived Pericoronary Fat Attenuation Index and AI-Based Cardiovascular Risk Score as a Proposed New Pathway in a Rapid Access Chest Pain Clinic: A Single-Centre Retrospective Registry Study
- Neointimal Hyperplasia and Restenosis: Epidemiology, Pathophysiology, Animal Models, Clinical Features, Diagnosis, and Management.
BibTeX
@article{liu2026pericoronary,
title = {{Pericoronary fat attenuation index and TyG index improve CCTA-based diagnosis of in-stent restenosis: a cross-sectional study}},
author = {Bing Liu and Xu Li and Mengyu Chen},
journal = {Frontiers in Cardiovascular Medicine},
year = {2026},
month = nov,
doi = {10.3389/fcvm.2026.1947118},
url = {https://www.frontiersin.org/articles/10.3389/fcvm.2026.1947118/full},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Pericoronary fat attenuation index and TyG index improve CCTA-based diagnosis of in-stent restenosis: a cross-sectional study
AU - Bing Liu
AU - Xu Li
AU - Mengyu Chen
PY - 2026
DA - 2026/11/20
JO - Frontiers in Cardiovascular Medicine
DO - 10.3389/fcvm.2026.1947118
UR - https://www.frontiersin.org/articles/10.3389/fcvm.2026.1947118/full
AB - Objective: This study investigated the associations of the pericoronary fat attenuation index (FAI) and triglyceride–glucose (TyG) index with in-stent restenosis (ISR) in patients with coronary artery disease (CAD) following stent implantation and evaluated the diagnostic value of combining these markers with coronary computed tomography angiography (CCTA). Methods: A total of 240 patients with previous stent implantation who underwent CCTA and coronary angiography (CAG) within one month were included. Pericoronary FAI was quantified from CCTA images using a semiautomated analysis system, and the TyG index was calculated. Patients were classified into ISR and non-ISR groups according to CAG findings. Clinical and imaging characteristics were compared between the groups. Patient-level associations with ISR were assessed using binary logistic regression, whereas stent-level analyses employed generalized estimating equations (GEE) to account for within-patient clustering. Receiver operating characteristic (ROC) curve analysis was used to evaluate the discriminative performance of CCTA, FAI and the TyG index, individually and in combination. Results: At the patient level, the ISR group had a higher TyG index (8.83 vs. 8.52, p = 0.006) and higher FAI around the right coronary artery (RCA) (−80.8 vs. −83.4 HU, p = 0.014). At the stent level, pre-stent FAI (−79.1 vs. −81.7 HU, p = 0.025), peri-stent FAI (−82.3 vs. −86.6 HU, p < 0.001), and the TyG index (8.85 vs. 8.58, p = 0.006) were higher in the ISR group. In multivariable GEE analysis, peri-stent FAI (OR = 1.063, p = 0.001) and the TyG index (OR = 1.685, p = 0.009) were independently associated with ISR. The area under the ROC curve (AUC) increased from 0.639 for CCTA alone to 0.734 for CCTA combined with peri-stent FAI and the TyG index ( p < 0.001). Conclusion: The TyG index and peri-stent FAI were independently associated with ISR. A diagnostic model combining these two markers with CCTA demonstrated better discrimination than CCTA alone.
SN - 2297-055X
ER -