AlGaN/GaN Hall-Effect Sensor for In-Situ Magnetic Field Monitoring of the HSX Stellarator
Abstract
Direct magnetic field sensors can address integration drift commonly observed in conventional inductive magnetic diagnostics used in fusion systems. In this work, an AlGaN/GaN Hall-effect sensor was fabricated, packaged, and deployed inside the Helically Symmetric eXperiment (HSX)---the first quasi-helically symmetric stellarator, operating with a 1 T on-axis magnetic field and up to 200 kW of launched electron cyclotron resonance heating (ECRH) power---for in-situ magnetic field monitoring near the plasma edge. The sensor leverages the high-mobility two-dimensional electron gas (2DEG) formed in the AlGaN/GaN heterostructure for sensitive magnetic field measurement, while the wide-bandgap GaN material system provides thermal robustness for harsh-environment operation. During 68 consecutive plasma discharge shots, the sensor remained functional and produced clear transient responses associated with plasma ignition and discharge dynamics. Comparisons between biased and unbiased operation, as well as plasma-discharge and coil-only shots, confirmed that the response originated from the biased Hall-effect sensor element. Furthermore, the sensor output exhibited temporal correlation with the plasma stored energy measured by the HSX diamagnetic loop across high-energy, late-breakdown, and failed-breakdown discharges.
Related
- Winding-Pack Quench Simulation of Stellarator Coils: Hydraulic Field-Network Coupling and Transverse Heat Conduction in OPENSC2
- High breakdown field multi-kV UWBG AlGaN transistors
- High-Field Electron Transport in AlGaN alloys: A Full-Band Monte Carlo Study Based on Ab Initio Supercell Calculations
- Distributed fiber optical multiparameter sensor combining three backscattering effects for structural health monitoring
- Unraveling hidden magnetic carriers in geological archives with a single spin quantum sensor
BibTeX
@misc{zhao2026algangan,
title = {{AlGaN/GaN Hall-Effect Sensor for In-Situ Magnetic Field Monitoring of the HSX Stellarator}},
author = {Yiming Zhao and Wayne Goodman and Thomas Gallenberger and Jasmine M. Cox and Benedikt Geiger and Debbie G. Senesky},
howpublished = {arXiv},
year = {2026},
month = aug,
doi = {10.48550/arxiv.2608.26704},
eprint = {2608.26704},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2608.26704},
}
RIS
TY - UNPB
TI - AlGaN/GaN Hall-Effect Sensor for In-Situ Magnetic Field Monitoring of the HSX Stellarator
AU - Yiming Zhao
AU - Wayne Goodman
AU - Thomas Gallenberger
AU - Jasmine M. Cox
AU - Benedikt Geiger
AU - Debbie G. Senesky
PY - 2026
DA - 2026/08/28
PB - arXiv
DO - 10.48550/arxiv.2608.26704
UR - https://arxiv.org/abs/2608.26704
AB - Direct magnetic field sensors can address integration drift commonly observed in conventional inductive magnetic diagnostics used in fusion systems. In this work, an AlGaN/GaN Hall-effect sensor was fabricated, packaged, and deployed inside the Helically Symmetric eXperiment (HSX)---the first quasi-helically symmetric stellarator, operating with a 1 T on-axis magnetic field and up to 200 kW of launched electron cyclotron resonance heating (ECRH) power---for in-situ magnetic field monitoring near the plasma edge. The sensor leverages the high-mobility two-dimensional electron gas (2DEG) formed in the AlGaN/GaN heterostructure for sensitive magnetic field measurement, while the wide-bandgap GaN material system provides thermal robustness for harsh-environment operation. During 68 consecutive plasma discharge shots, the sensor remained functional and produced clear transient responses associated with plasma ignition and discharge dynamics. Comparisons between biased and unbiased operation, as well as plasma-discharge and coil-only shots, confirmed that the response originated from the biased Hall-effect sensor element. Furthermore, the sensor output exhibited temporal correlation with the plasma stored energy measured by the HSX diamagnetic loop across high-energy, late-breakdown, and failed-breakdown discharges.
ER -