Quantification of Fosfomycin in Plasma by LC-MS/MS: Development, Validation and Application to Pharmacological Monitoring.

2 more authors
  1. 1Laboratory of Clinical Pharmacology and Pharmacogenetics, Department of Medical Sciences, University of Turin, 10149 Turin, Italy.
  2. 2ASL Città di Torino, Amedeo di Savoia Hospital, 10149 Turin, Italy.

Abstract

Fosfomycin is an antibiotic of growing interest for the treatment of infections caused by multidrug-resistant bacteria. Its marked pharmacokinetic variability, especially in critically ill patients, makes therapeutic drug monitoring (TDM) useful to ensure adequate exposure and to limit the risk of treatment failure, resistance development, and toxicity. Given the high polarity of fosfomycin, a hydrophilic interaction liquid chromatography- tandem mass spectrometry (HILIC-MS/MS) method for its quantification in human plasma was developed and validated, using a Phenomenex Luna Polar Pesticides column, a Shimadzu LCMS-8050 mass spectrometer operated in negative electrospray ionisation mode and fosfomycin-d5 as internal standard. Sample preparation relied on a single-step protein precipitation of 40 µL of plasma, with a retention time of 2.8 min and a total run time of seven min. Validation according to the International Council for Harmonisation (ICH) M10 guideline demonstrated linearity over 1.56-200 mg/L (lower limit of quantification of 1.56 mg/L; limit of detection 0.19 mg/L), intra- and inter-day precision and accuracy within acceptance criteria acceptable recovery and matrix effect in six independent plasma lots, and no relevant endogenous interference. The method was applied to 44 samples from six patients receiving intravenous fosfomycin, and incurred sample reanalysis met ICH M10 acceptance criteria. This method provides a sensitive, selective, and robust tool for fosfomycin TDM pharmacokinetic studies.

Related

  1. Development and Validation of an HPLC-DAD Method for the Quantification of a Melatonin–Furanochalcone Hybrid and Its Application in a Pharmacokinetic Study in a Murine Model
    Estefany D. J. Silva-Gutiérrez, Juan D. Zapata, Andrés F. Yepes +2
    MoleculesPeer-reviewedCC BY 4.0General chemistryCrossref
  2. Quantification of D55, an apomorphine derivative, in mouse plasma by LC–MS/MS: method development, validation, and improved pharmacokinetics compared with apomorphine
    Kohei Nagai, Natsuka Kimura, Tamaki Ishima +2
    BioanalysisPeer-reviewedLicence not statedFull textAnalytical chemistryPMC
  3. Simultaneous quantification of Minoxidil and Dexpanthenol in topical solutions: Development and validation of a RP-HPLC procedure
    Aya Sabouny, Ali Ibrahim, Saleh Trefi +1
    Bulletin of Pharmaceutical Sciences. Assiut UniversityPeer-reviewedCC BYFull textAnalytical chemistryDOAJ
  4. Analytical Method Development and Validation for the Quantification of Related Substances in Pantoprazole Gastro-Resistant Tablets by RP-HPLC: A Critical Review
    Abirami A, Prarthana J, Surya R +1
    International Journal of Research in Pharmaceutical SciencesPeer-reviewedCC BYFull textAnalytical chemistryDOAJ
  5. Development and validation of a novel candidate reference procedure for the quantification of 3-nitro-L-tyrosine, 3-monoiodo-L-tyrosine and 3,5-diiodo-L-tyrosine in urine by isotope dilution and LC-ESI-MS/MS
    Heli Potes-Rodriguez, Pablo Rodríguez-González, Juan Manuel Marchante-Gayon +6
    Microchemical JournalPeer-reviewedCC BY-NC-ND 4.0Full textAnalytical chemistryHAL
BibTeX
@article{palermiti2026quantification,
  title = {{Quantification of Fosfomycin in Plasma by LC-MS/MS: Development, Validation and Application to Pharmacological Monitoring.}},
  author = {Alice Palermiti and Camilla Martino and Maria Donata Valenti and Miriam Antonucci and Sara Soloperto and Martina Billi and Gianluca Bianco and Riccardo Marras and Elisa Martina and Federica Barrera and Sabrina Audagnotto and Jessica Cusato and Antonio D'Avolio and Amedeo De Nicolò},
  journal = {Journal of xenobiotics},
  year = {2026},
  month = nov,
  doi = {10.3390/jox16070212},
  url = {https://europepmc.org/article/MED/43083267},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Quantification of Fosfomycin in Plasma by LC-MS/MS: Development, Validation and Application to Pharmacological Monitoring.
AU  - Alice Palermiti
AU  - Camilla Martino
AU  - Maria Donata Valenti
AU  - Miriam Antonucci
AU  - Sara Soloperto
AU  - Martina Billi
AU  - Gianluca Bianco
AU  - Riccardo Marras
AU  - Elisa Martina
AU  - Federica Barrera
AU  - Sabrina Audagnotto
AU  - Jessica Cusato
AU  - Antonio D'Avolio
AU  - Amedeo De Nicolò
PY  - 2026
DA  - 2026/11/01
JO  - Journal of xenobiotics
DO  - 10.3390/jox16070212
UR  - https://europepmc.org/article/MED/43083267
AB  - Fosfomycin is an antibiotic of growing interest for the treatment of infections caused by multidrug-resistant bacteria. Its marked pharmacokinetic variability, especially in critically ill patients, makes therapeutic drug monitoring (TDM) useful to ensure adequate exposure and to limit the risk of treatment failure, resistance development, and toxicity. Given the high polarity of fosfomycin, a hydrophilic interaction liquid chromatography- tandem mass spectrometry (HILIC-MS/MS) method for its quantification in human plasma was developed and validated, using a Phenomenex Luna Polar Pesticides column, a Shimadzu LCMS-8050 mass spectrometer operated in negative electrospray ionisation mode and fosfomycin-d5 as internal standard. Sample preparation relied on a single-step protein precipitation of 40 µL of plasma, with a retention time of 2.8 min and a total run time of seven min. Validation according to the International Council for Harmonisation (ICH) M10 guideline demonstrated linearity over 1.56-200 mg/L (lower limit of quantification of 1.56 mg/L; limit of detection 0.19 mg/L), intra- and inter-day precision and accuracy within acceptance criteria acceptable recovery and matrix effect in six independent plasma lots, and no relevant endogenous interference. The method was applied to 44 samples from six patients receiving intravenous fosfomycin, and incurred sample reanalysis met ICH M10 acceptance criteria. This method provides a sensitive, selective, and robust tool for fosfomycin TDM pharmacokinetic studies.
SN  - 2039-4705
SN  - 2039-4713
ER  -