Skip to content
DraconiticResearch
Search Sources API
201,818 studies31 sourcesUpdated 57 min ago
PreprintCC BY-NC-NDbioRxiv

Development of a Wearable Sensor-PAM for Continuous Monitoring of Photosynthetic Dynamics

  1. 1Kyoto University

Abstract

Continuous monitoring of photosynthetic performance is essential for understanding plant responses to fluctuating environments and has important applications in plant physiology, field phenotyping, and digital agriculture. However, conventional pulse-amplitude modulation (PAM) fluorometers are primarily designed for point measurements and are not suitable for long-term monitoring while attached to intact leaves. Here, we developed Sensor-PAM, a wearable chlorophyll fluorescence measurement system capable of continuously monitoring photosynthetic dynamics from the abaxial side of a leaf. The system combines a commercially available color sensor with blue LEDs in a compact, low-cost optical design to perform PAM measurements. Chlorophyll fluorescence measured from the abaxial leaf surface showed a strong correlation with conventional adaxial measurements and accurately reflected changes in photosynthetic performance induced by chilling and high-light stress. Measurements obtained using Sensor-PAM also showed good agreement with those from a commercial PAM fluorometer across diverse plant species. Furthermore, the wearable system enabled continuous monitoring of the effective quantum yield of photosystem II [Y(II)] from the same position on the same strawberry leaf for three days under both greenhouse and outdoor conditions, successfully capturing photosynthetic responses to changing irradiance and temperature in real time. These findings establish Sensor-PAM as a wearable platform for continuous chlorophyll fluorescence monitoring, extending conventional PAM fluorometry from point-based measurements to long-term monitoring of photosynthetic dynamics under natural environmental conditions.

Related

  1. Frequency modulated semi-continuous wave Doppler ultrasound: A novel method for the detection of scatterer velocity and range using wearable ultrasound instrumentation
    C. M. Delaney, A. Bashatah, A. Aher +4
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
  2. Effects of Shading-Induced Senescence and Retention of Lower-Canopy Needles on Photosynthetic Dynamics in Upper-Canopy Needles of Cunninghamia lanceolata
    Yueyue He, Yu Zhang, Qi Liu +4
    Plants (Basel, Switzerland)Peer-reviewedCC BYFull textPlant biologyEurope PMC
  3. Compact target-aware stability-based feature selection for cross-dataset wearable activity monitoring
    Sarra Ayouni, Maha Sliti, Abeer Abdulaziz Alghanem +2
    PLOS OnePeer-reviewedCC BY 4.0Full textNeurosciencePhysiologyPLOS
  4. Short-term prediction of COPD exacerbations based on wearable vital sign monitoring
    Florian Tilquin, Sylvain Le Liepvre, Soumaya Balbolia +7
    PLOS Digital HealthPeer-reviewedCC BYFull textGeneral biologyHAL
  5. Premature Ventricular Contractions at Extreme Altitude: Continuous Electrocardiographic Monitoring on Mount Everest.
    Domenico Angellotti, Kunjang Sherpa, Tamara Käppeli +3
    JACC. AdvancesPeer-reviewedCC BYFull textGenetics & genomicsEurope PMC
BibTeX
@misc{miyamoto2026development,
  title = {{Development of a Wearable Sensor-PAM for Continuous Monitoring of Photosynthetic Dynamics}},
  author = {K.-i. Miyamoto and K. Ifuku and T. Yoshinobu and K. Kohzuma},
  howpublished = {bioRxiv},
  year = {2026},
  month = sep,
  doi = {10.64898/2026.09.12.751108},
  url = {https://www.biorxiv.org/content/10.64898/2026.09.12.751108v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - Development of a Wearable Sensor-PAM for Continuous Monitoring of Photosynthetic Dynamics
AU  - K.-i. Miyamoto
AU  - K. Ifuku
AU  - T. Yoshinobu
AU  - K. Kohzuma
PY  - 2026
DA  - 2026/09/12
PB  - bioRxiv
DO  - 10.64898/2026.09.12.751108
UR  - https://www.biorxiv.org/content/10.64898/2026.09.12.751108v1
AB  - Continuous monitoring of photosynthetic performance is essential for understanding plant responses to fluctuating environments and has important applications in plant physiology, field phenotyping, and digital agriculture. However, conventional pulse-amplitude modulation (PAM) fluorometers are primarily designed for point measurements and are not suitable for long-term monitoring while attached to intact leaves. Here, we developed Sensor-PAM, a wearable chlorophyll fluorescence measurement system capable of continuously monitoring photosynthetic dynamics from the abaxial side of a leaf. The system combines a commercially available color sensor with blue LEDs in a compact, low-cost optical design to perform PAM measurements. Chlorophyll fluorescence measured from the abaxial leaf surface showed a strong correlation with conventional adaxial measurements and accurately reflected changes in photosynthetic performance induced by chilling and high-light stress. Measurements obtained using Sensor-PAM also showed good agreement with those from a commercial PAM fluorometer across diverse plant species. Furthermore, the wearable system enabled continuous monitoring of the effective quantum yield of photosystem II [Y(II)] from the same position on the same strawberry leaf for three days under both greenhouse and outdoor conditions, successfully capturing photosynthetic responses to changing irradiance and temperature in real time. These findings establish Sensor-PAM as a wearable platform for continuous chlorophyll fluorescence monitoring, extending conventional PAM fluorometry from point-based measurements to long-term monitoring of photosynthetic dynamics under natural environmental conditions.
ER  -