Multilayer Heater Nano cryotrons: Electrothermal Modeling of Geometry-Dependent Switching
Abstract
This paper presents a finite-element framework to study how device geometry affects the switching current of multilayer heater nano cryotrons (hTrons). The device comprises a 50 nm Au/5 nm Ti heater, a 100 nm SiO2 spacer, a 23.6 nm NbN channel, and a Si substrate. Two-dimensional electrothermal simulations examine nine heater and channel width combinations using widths of 100, 500, and 1000 nm. Three-dimensional simulations show how heat flows through the layers and spreads across the channel near the heater-channel overlap. Heater electrical losses and heat transport are coupled, whereas the channel switching threshold is obtained separately from a temperature-dependent constitutive relation. Published global temperature measurements support the switching-law calibration, and heater-current measurements assess the resulting device response. The model measurement comparisons show a systematic reduction of switching-current density with heating, but also geometry-dependent discrepancies in the low-drive plateau and transition shape. A common extraction protocol is formulated for heater-current and heater-power requirements at a specified suppression level, while separating fitted device amplitudes from controlled geometry effects. The resulting comparisons connect thermal fields to design metrics while distinguishing calibration from validation and excluding transient-performance claims from the stationary analysis
Related
- Mathematical modeling of regime-dependent thermal response in multilayer wall assemblies with equal total steady thermal resistance
- Physics-Based TCAD Modeling of Nanowire Cryotrons with Coupled Superconducting and Thermal Dynamics
- Surrogate-Assisted Inverse Design and Temperature-Dependent Electrothermal Analysis of an All-Oxide Narrowband Thermophotovoltaic Emitter
- Current-voltage characteristics and resistive switching in epitaxial La0.67Sr0.33MnO3/SrMnO3/La0.67Sr0.33MnO3 multilayer
- Feasibility study of Laser Parameter Estimation from High-Order Harmonic Spectra Using an Input-Dependent Gated Multilayer Perceptron
BibTeX
@misc{barua2026multilayer,
title = {{Multilayer Heater Nano cryotrons: Electrothermal Modeling of Geometry-Dependent Switching}},
author = {Baibhari Priya Barua and Md Rahatul Islam Udoy and Shamiul Alam and Md Shafayat Hossain and Ahmedullah Aziz},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.10868},
eprint = {2611.10868},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.10868},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Multilayer Heater Nano cryotrons: Electrothermal Modeling of Geometry-Dependent Switching
AU - Baibhari Priya Barua
AU - Md Rahatul Islam Udoy
AU - Shamiul Alam
AU - Md Shafayat Hossain
AU - Ahmedullah Aziz
PY - 2026
DA - 2026/11/07
PB - arXiv
DO - 10.48550/arxiv.2611.10868
UR - https://arxiv.org/abs/2611.10868
AB - This paper presents a finite-element framework to study how device geometry affects the switching current of multilayer heater nano cryotrons (hTrons). The device comprises a 50 nm Au/5 nm Ti heater, a 100 nm SiO2 spacer, a 23.6 nm NbN channel, and a Si substrate. Two-dimensional electrothermal simulations examine nine heater and channel width combinations using widths of 100, 500, and 1000 nm. Three-dimensional simulations show how heat flows through the layers and spreads across the channel near the heater-channel overlap. Heater electrical losses and heat transport are coupled, whereas the channel switching threshold is obtained separately from a temperature-dependent constitutive relation. Published global temperature measurements support the switching-law calibration, and heater-current measurements assess the resulting device response. The model measurement comparisons show a systematic reduction of switching-current density with heating, but also geometry-dependent discrepancies in the low-drive plateau and transition shape. A common extraction protocol is formulated for heater-current and heater-power requirements at a specified suppression level, while separating fitted device amplitudes from controlled geometry effects. The resulting comparisons connect thermal fields to design metrics while distinguishing calibration from validation and excluding transient-performance claims from the stationary analysis
ER -