Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 41 min ago
PreprintCC BY-NC-ND 4.0arXiv

Scan-Coil Delay Causes Anisotropic Signal Loss in Fast 4D-STEM

Abstract

Fast pixelated detectors are driving 4D-STEM toward microsecond dwell times, a regime in which the finite response of the scan deflection coils becomes comparable to the dwell time itself. Using direct probe imaging and sub-frame diffraction analysis, we document a significant intra-dwell scan-coil delay that systematically smears the recorded signal anisotropically along the fast scan direction, with a settling timescale of several tens of microseconds. We present a phase-correlation-based sub-frame alignment procedure that measures and corrects this smearing, and we assess its impact on focused and defocused 4D-STEM reconstructions over a range of scan step sizes. The correction restores signal across a broad range of spatial frequencies, with the largest gains at the large step sizes required for low-dose biological imaging. Because it operates on existing data with no modification to the microscope, the method offers a practical route to recovering signal that would otherwise be lost to scan-coil delay.

Related

  1. Luminal geometry and coiled coil length determine submembrane localization of type II transmembrane Golgi proteins
    Jing Xue Wong, Barbara Hübner, Divyanshu Mahajan +5
    Nature CommunicationsPeer-reviewedCC BY-NC-ND 4.0Full textCell biologyCrossref
  2. Multiple lesions on a PET-scan
    S. Beuzit, M. Gobert, C. de Moreuil +1
    La Revue de Médecine InternePeer-reviewedCC BY-NC-ND 4.0Full textImmunologySystems & synthetic biologyHAL
  3. A scan for repeat-mediated genomic disorders in clinical cases of male infertility
    Arvand Akbari, Antoni Riera-Escamilla, Maliha Tasnim +4
    BMC GenomicsPeer-reviewedCC BY 4.0Genetics & genomicsCrossref
  4. Genome-wide scan for transmission ratio distortion in trios from the Norwegian MoBa cohort rules out moderate distortion at common variants
    Shannon D’Urso, Elizabeth C. Corfield, Laurie J. Hannigan +9
    Genome BiologyPeer-reviewedCC BY 4.0Molecular biology & gene regulationGenetics & genomicsCrossref
  5. Structural basis of coiled-coil domain-mediated inhibition of A. baumannii AbTir NAD+ nucleosidase activity
    W. Gu, M. K. Manik, C. Jobichen +13
    bioRxivPreprintCC BY-NC-NDFull textImmunologybioRxiv
BibTeX
@misc{kumar2026scancoil,
  title = {{Scan-Coil Delay Causes Anisotropic Signal Loss in Fast 4D-STEM}},
  author = {Vishal Kumar and Andreas Jehle and Tizian Lorenzen and Julika Radecke and Knut Müller-Caspary and Massimo Kube and Henning Stahlberg},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2608.13106},
  eprint = {2608.13106},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2608.13106},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - UNPB
TI  - Scan-Coil Delay Causes Anisotropic Signal Loss in Fast 4D-STEM
AU  - Vishal Kumar
AU  - Andreas Jehle
AU  - Tizian Lorenzen
AU  - Julika Radecke
AU  - Knut Müller-Caspary
AU  - Massimo Kube
AU  - Henning Stahlberg
PY  - 2026
DA  - 2026/10/14
PB  - arXiv
DO  - 10.48550/arxiv.2608.13106
UR  - https://arxiv.org/abs/2608.13106
AB  - Fast pixelated detectors are driving 4D-STEM toward microsecond dwell times, a regime in which the finite response of the scan deflection coils becomes comparable to the dwell time itself. Using direct probe imaging and sub-frame diffraction analysis, we document a significant intra-dwell scan-coil delay that systematically smears the recorded signal anisotropically along the fast scan direction, with a settling timescale of several tens of microseconds. We present a phase-correlation-based sub-frame alignment procedure that measures and corrects this smearing, and we assess its impact on focused and defocused 4D-STEM reconstructions over a range of scan step sizes. The correction restores signal across a broad range of spatial frequencies, with the largest gains at the large step sizes required for low-dose biological imaging. Because it operates on existing data with no modification to the microscope, the method offers a practical route to recovering signal that would otherwise be lost to scan-coil delay.
ER  -