Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 10 min ago
PreprintCC BY 4.0Research Square

Automated Radiosynthesis of [18F]Fluoroedaravone for Clinical Research on a Commercially Available Trasis AllinOne Radiosynthesizer

Abstract

Background Measuring reactive oxygen and nitrogen species (RONS) in vivo remains challenging to date, thereby limiting our understanding of the role oxidative stress plays in neurodegenerative disease pathogenesis. Current PET tracers developed to detect RONS face limitations in biological stability, blood-brain barrier permeability, and RONS specificity. A novel PET tracer for RONS, [ 18 F]fluoroedaravone ([¹⁸F]FEDV), was recently reported that demonstrates high contrast in vivo with high specificity for RONS. The previously reported synthesis of [ 18 F]FEDV was performed manually, therefore, the goal of this study was to develop and optimize a robust and reproducible automated method for the synthesis of [ 18 F]FEDV on a commercially available Trasis AllinOne (AiO) radiosynthesizer for routine preclinical and clinical research use. Results The [¹⁸F]FEDV synthesis was adapted from a manual protocol into a fully automated two-pot, three-step process on the Trasis AiO radiosynthesizer. Optimization included varying precursor masses, radiofluorination times, temperatures, dilution conditions, purification and reformulation parameters. The optimized synthesis and purification process was completed in 105 min and produced [¹⁸F]FEDV with a radiochemical yield of 11.4% ± 1.5% (n = 50), radiochemical purity of 97.5% ± 1.4% (n = 25), chemical impurities < 100 µg/dose, and a pH of 5.0. This automated process produced [¹⁸F]FEDV with high reproducibility and reliability suitable for clinical use. The process was validated to meet USP < 823 > regulatory requirements including full QC testing on three consecutive batches. Conclusions An automated method for the radiochemical synthesis of [ 18 F]fluoroedaravone was developed and optimized on a commercially available Trasis AiO radiosynthesizer. This method allows for the reliable production of [ 18 F]FEDV for supporting preclinical research and first in human clinical trials.

Related

  1. Antibiotic-Loaded Hydrogel, Calcium Bead, and Cement in Periprosthetic Joint Infection Following Hip-Knee Arthroplasty: A Systematic Review and Meta-Analysis of Commercially Available Products
    Journal of the American Academy of Orthopaedic Surgeons. Global research & reviewsPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  2. Objective Comparison of Commercially Available Virtual Reality Perimetry Devices: a cross-sectional descriptive study
    Coy Steel, Matthew Vierkant, Maral Namdari +5
    Research SquarePreprintCC BY 4.0Full textGeneral medicinePMC
  3. An Epidemic of Misbranding: Marketplace Surveillance of MGM-15 and Kratom Alkaloids in Commercially Available Tablets by QuEChERS -LCMS/MS
    Ana Barovic, Mitchell L. Ellinwood, Shelby Blanchart +5
    ChemRxivPreprintCC BY-NC-NDFull textPharmacology & toxicologyChemRxiv
  4. Preclinical safety evaluation of Vernolac, a commercially available polyherbal nutraceutical comprising Vernonia zeylanica, Nigella sativa, Hemidesmus indicus, Smilax glabra, and Leucas zeylanica, in Wistar rats
    Shalini Kaushalya Wijerathne, Oshadi V Epitawala Arachchige, Sandani De Vass Gunawardane +7
    PLOS OnePeer-reviewedCC BYFull textZoology & animal behaviourOncologyPLOSEurope PMCPMC
  5. Comparative Evaluation of Two Commercially Available Topical Gels As Adjuncts to Scaling and Root Planing for Gingival Inflammation: A Randomized Controlled Trial.
    Abhishek Sharma, Ajay Mahajan, Kanwarjit Singh Asi
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@misc{ghosh2026automated,
  title = {{Automated Radiosynthesis of [18F]Fluoroedaravone for Clinical Research on a Commercially Available Trasis AllinOne Radiosynthesizer}},
  author = {Arijit Ghosh and Joana Marie A. Almazan and Ivan E. Wang and Allison J. Clay and Spenser R. Simpson and Kiel D. Neumann and Amy L. Vavere},
  howpublished = {Research Square},
  year = {2026},
  month = nov,
  doi = {10.21203/rs.3.rs-11368315/v1},
  url = {https://doi.org/10.21203/rs.3.rs-11368315/v1},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Automated Radiosynthesis of [18F]Fluoroedaravone for Clinical Research on a Commercially Available Trasis AllinOne Radiosynthesizer
AU  - Arijit Ghosh
AU  - Joana Marie A. Almazan
AU  - Ivan E. Wang
AU  - Allison J. Clay
AU  - Spenser R. Simpson
AU  - Kiel D. Neumann
AU  - Amy L. Vavere
PY  - 2026
DA  - 2026/11/04
PB  - Research Square
DO  - 10.21203/rs.3.rs-11368315/v1
UR  - https://doi.org/10.21203/rs.3.rs-11368315/v1
AB  - Background Measuring reactive oxygen and nitrogen species (RONS) in vivo remains challenging to date, thereby limiting our understanding of the role oxidative stress plays in neurodegenerative disease pathogenesis. Current PET tracers developed to detect RONS face limitations in biological stability, blood-brain barrier permeability, and RONS specificity. A novel PET tracer for RONS, [ 18 F]fluoroedaravone ([¹⁸F]FEDV), was recently reported that demonstrates high contrast in vivo with high specificity for RONS. The previously reported synthesis of [ 18 F]FEDV was performed manually, therefore, the goal of this study was to develop and optimize a robust and reproducible automated method for the synthesis of [ 18 F]FEDV on a commercially available Trasis AllinOne (AiO) radiosynthesizer for routine preclinical and clinical research use. Results The [¹⁸F]FEDV synthesis was adapted from a manual protocol into a fully automated two-pot, three-step process on the Trasis AiO radiosynthesizer. Optimization included varying precursor masses, radiofluorination times, temperatures, dilution conditions, purification and reformulation parameters. The optimized synthesis and purification process was completed in 105 min and produced [¹⁸F]FEDV with a radiochemical yield of 11.4% ± 1.5% (n = 50), radiochemical purity of 97.5% ± 1.4% (n = 25), chemical impurities < 100 µg/dose, and a pH of 5.0. This automated process produced [¹⁸F]FEDV with high reproducibility and reliability suitable for clinical use. The process was validated to meet USP < 823 > regulatory requirements including full QC testing on three consecutive batches. Conclusions An automated method for the radiochemical synthesis of [ 18 F]fluoroedaravone was developed and optimized on a commercially available Trasis AiO radiosynthesizer. This method allows for the reliable production of [ 18 F]FEDV for supporting preclinical research and first in human clinical trials.
SN  - 2693-5015
ER  -