Background-Suppressed Infrared Photothermal Microscopy at Low Temperature.
4 affiliations
- 1Department of Biomedical Engineering, Boston University, Boston, Massachusetts 02215, United States.
- 2Department of Electrical & Computer Engineering, Boston University, Boston, Massachusetts 02215, United States.
- 3Photonics Center, Boston, Massachusetts 02215, United States.
- 4Graduate Program of Molecular Biology, Cell Biology, and Biochemistry, Boston University, Boston, Massachusetts 02215, United States.
Abstract
The short-wave infrared region provides reduced scattering and improved penetration depth compared to visible and near-infrared wavelengths. However, strong water absorption across this spectral window generates background signals that limit the contrast and obscure weak biomolecular features. To address this challenge, we implement a low-temperature approach that exploits the temperature dependence of the water photothermal response to suppress background while preserving lipid-derived signals in photothermal microscopy. Sample cooling during imaging enhanced the signal-to-background ratio (S/B) by up to 5.5-fold in cellular imaging and improved the contrast-to-noise ratio (CNR) of weak lipid features by up to 1.6-fold at greater tissue depths, enabling reliable volumetric imaging in complex biological systems. We further show that a low-temperature approach is also applicable to mid-infrared photothermal microscopy, thus providing an effective means to enhance the photothermal contrast of aqueous specimens.
Related
- A unified framework for sensitivity comparison across stimulated Raman, stimulated Raman photothermal, and mid-infrared photothermal microscopy
- Spectroscopically Evaluating Composition and Crystallinity in Pristine and UV-Exposed PET Films Using Polarization-Dependent Optical Photothermal Infrared Microscopy.
- Advanced background removal methods in single molecule localization microscopy using scattering networks and SVD
- Label-free identification and classification of leukocyte subpopulations in peripheral blood smears by optical photothermal infrared spectroscopy
- Monitoring Early Infection Dynamics in Live Spodoptera frugiperda (Sf) 9 Cells via Optical Photothermal Infrared (OPTIR) Spectroscopy.
BibTeX
@article{pham2026backgroundsuppressed,
title = {{Background-Suppressed Infrared Photothermal Microscopy at Low Temperature.}},
author = {Thao N Pham and Jiaze Yin and Yuhao Yuan and Dingcheng Sun and Bethany Weinberg and Hongli Ni and Ji-Xin Cheng},
journal = {Chemical \& biomedical imaging},
year = {2026},
month = jun,
doi = {10.1021/cbmi.6c00068},
url = {https://europepmc.org/article/MED/42953291},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Background-Suppressed Infrared Photothermal Microscopy at Low Temperature.
AU - Thao N Pham
AU - Jiaze Yin
AU - Yuhao Yuan
AU - Dingcheng Sun
AU - Bethany Weinberg
AU - Hongli Ni
AU - Ji-Xin Cheng
PY - 2026
DA - 2026/06/02
JO - Chemical & biomedical imaging
DO - 10.1021/cbmi.6c00068
UR - https://europepmc.org/article/MED/42953291
AB - The short-wave infrared region provides reduced scattering and improved penetration depth compared to visible and near-infrared wavelengths. However, strong water absorption across this spectral window generates background signals that limit the contrast and obscure weak biomolecular features. To address this challenge, we implement a low-temperature approach that exploits the temperature dependence of the water photothermal response to suppress background while preserving lipid-derived signals in photothermal microscopy. Sample cooling during imaging enhanced the signal-to-background ratio (S/B) by up to 5.5-fold in cellular imaging and improved the contrast-to-noise ratio (CNR) of weak lipid features by up to 1.6-fold at greater tissue depths, enabling reliable volumetric imaging in complex biological systems. We further show that a low-temperature approach is also applicable to mid-infrared photothermal microscopy, thus providing an effective means to enhance the photothermal contrast of aqueous specimens.
SN - 2832-3637
ER -