Peer-reviewedCC BY 4.0In Vitro Models

Model-based cost-minimization analysis of electrochemical hydrogen peroxide screening for oxidative stress evaluation using airways epithelial cell systems

2 more authors
4 affiliations
  1. 1Institute of Translational Pharmacology, Italian National Research Council (CNR), 90146 Palermo, Italy
  2. 2PhD National Program in One Health approaches to infectious diseases and life science research, Department of Public Health, Experimental and Forensic Medicine, University of Pavia, 27100 Pavia, Italy
  3. 3Fondazione Ri.MED, 90100 Palermo, Italy
  4. 4Dipartimento di Ingegneria, Università degli Studi di Palermo, 90100 Palermo, Italy

Abstract

Oxidative stress is a common event in a variety of chronic diseases and its detection is confined to equipped laboratories with dedicated instruments and with personnel with high specialization. Electrochemical sensors have been demonstrated to be effective, easy-to-use, and reliable tools for quantifying extracellular hydrogen peroxide (H₂O₂) in airway epithelial preclinical models. Economic analyses of biomedical studies are increasingly needed. The present cost-minimization analysis compares the experimental costs of a traditional oxidative stress workflow with those of a screening strategy based on electrochemical H₂O₂ detection. The experimental design included bronchial epithelial cells exposed to cigarette smoke extract (CSE), as oxidative stress inducer, at three different concentrations and for three time points. As downstream events to CSE exposure, it was planned to assess mitochondrial superoxide production, toll-like receptor 4 (TLR4) and NF-kB expression, IL-8 gene expression and concentrations, and fluorescent advanced glycation end products (fAGE). The detection of H₂O₂ by electrochemical sensors in culture supernatants enables downstream events to be assessed only under conditions in which an extracellular oxidative response is detected, allowing the identification of the optimal time point and stimulus concentration. Considering a failure rate of 23% for both methods, the sensor-based approach reduces the overall experimental cost by 85.67% compared with the traditional ones. This value reflects the decrease in consumables and personnel time associated with preliminary screening performed with electrochemical sensors. In conclusion, the present analysis supports the utility of electrochemical sensors in optimizing research costs of preclinical studies aimed at assessing oxidative homeostasis perturbation and relative downstream events.

Related

  1. Epithelial-endothelial barrier dysfunction and oxidative stress in ARDS subphenotypes: comparative efficacy of extracellular vesicles derived from bone marrow (MSC-EVs) and adipose tissue (ASC-EVs) mesenchymal stem cells
    A. Burello, G. Tiberi, P. A. D. Villegas +14
    medRxivPreprintAll rights reservedFull textMolecular biology & gene regulationmedRxiv
  2. Effects of a Two-Strain Lactobacillus Formulation (Lactobacillus rhamnosus L34 and Lactobacillus paracasei B13) on Inflammatory and Oxidative Markers, Epithelial Junction Proteins, and Fecal Microbiota in Rats with DNBS-Induced Colitis
    Pakkapon Rattanachaisit, Nathawadee Lerttanatum, Somying Tumwasorn +3
    International Journal of Molecular SciencesPeer-reviewedCC BY 4.0General biochemistryCrossref
  3. Lutein-Rich Extract from Gac (Momordica cochinchinensis) Fruit Peel Protects Retinal Pigment Epithelial Cells from Oxidative and Inflammatory Stress
    Dao Nguyen, Thilini Thrimawithana, Terrence Piva +1
    International Journal of Molecular SciencesPeer-reviewedCC BY 4.0Full textGeneral biochemistryCrossrefEurope PMC
  4. In Silico-Guided Screening of a High-Affinity PD-L1 Aptamer for the Construction of a Sensitive Electrochemical Aptasensor.
    Lin Zha, Xiaonan Pang, Zhongxuan Gui +3
    BiosensorsPeer-reviewedCC BYFull textMolecular biology & gene regulationEurope PMC
  5. Simvastatin and Primaquine Identified as Potential Endometriosis Therapeutics via a Novel Epithelial-Stromal Assembloid Drug Screening Assay
    F. Abbasi, X. Tang, J. C. Irwin +5
    bioRxivPreprintCC BY-NC-NDFull textMolecular biology & gene regulationbioRxiv
BibTeX
@article{donzi2026modelbased,
  title = {{Model-based cost-minimization analysis of electrochemical hydrogen peroxide screening for oxidative stress evaluation using airways epithelial cell systems}},
  author = {Daniele Donzì and Maria Rita Marabeti and Paola Pinto and Anna Bonomolo and Serena Di Vincenzo and Maria Ferraro and Caterina Cascio and Giuseppina Chiappara and Chiara Cipollina and Nadia Moukri and Bernardo Patella and Andreina Bruno and Rosalinda Inguanta and Elisabetta Pace},
  journal = {In Vitro Models},
  year = {2026},
  month = aug,
  doi = {10.1007/s44164-026-00146-6},
  url = {https://doi.org/10.1007/s44164-026-00146-6},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Model-based cost-minimization analysis of electrochemical hydrogen peroxide screening for oxidative stress evaluation using airways epithelial cell systems
AU  - Daniele Donzì
AU  - Maria Rita Marabeti
AU  - Paola Pinto
AU  - Anna Bonomolo
AU  - Serena Di Vincenzo
AU  - Maria Ferraro
AU  - Caterina Cascio
AU  - Giuseppina Chiappara
AU  - Chiara Cipollina
AU  - Nadia Moukri
AU  - Bernardo Patella
AU  - Andreina Bruno
AU  - Rosalinda Inguanta
AU  - Elisabetta Pace
PY  - 2026
DA  - 2026/08/05
JO  - In Vitro Models
DO  - 10.1007/s44164-026-00146-6
UR  - https://doi.org/10.1007/s44164-026-00146-6
AB  - Oxidative stress is a common event in a variety of chronic diseases and its detection is confined to equipped laboratories with dedicated instruments and with personnel with high specialization. Electrochemical sensors have been demonstrated to be effective, easy-to-use, and reliable tools for quantifying extracellular hydrogen peroxide (H₂O₂) in airway epithelial preclinical models. Economic analyses of biomedical studies are increasingly needed. The present cost-minimization analysis compares the experimental costs of a traditional oxidative stress workflow with those of a screening strategy based on electrochemical H₂O₂ detection. The experimental design included bronchial epithelial cells exposed to cigarette smoke extract (CSE), as oxidative stress inducer, at three different concentrations and for three time points. As downstream events to CSE exposure, it was planned to assess mitochondrial superoxide production, toll-like receptor 4 (TLR4) and NF-kB expression, IL-8 gene expression and concentrations, and fluorescent advanced glycation end products (fAGE). The detection of H₂O₂ by electrochemical sensors in culture supernatants enables downstream events to be assessed only under conditions in which an extracellular oxidative response is detected, allowing the identification of the optimal time point and stimulus concentration. Considering a failure rate of 23% for both methods, the sensor-based approach reduces the overall experimental cost by 85.67% compared with the traditional ones. This value reflects the decrease in consumables and personnel time associated with preliminary screening performed with electrochemical sensors. In conclusion, the present analysis supports the utility of electrochemical sensors in optimizing research costs of preclinical studies aimed at assessing oxidative homeostasis perturbation and relative downstream events.
SN  - 2731-3433
SN  - 2731-3441
ER  -