Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 16 min ago
PreprintarXiv licencearXiv

Feasibility of a Patient-Specific Digital Twin for Ventriculoperitoneal Shunt Trajectory Planning

Abstract

Catheter obstruction is the commonest cause of shunt failure; freehand insertion at Keen's point leaves the tip free in cerebrospinal fluid in only one case in ten. We built a digital twin that reconstructs skull, scalp, ear and ventricles from preoperative CT by deterministic geometry, searches every entry around Keen's point for the perpendicular trajectory with the longest intraventricular length under safety constraints, and returns the plan as two ruler measurements from the ear and two depths. Executed freehand in 11 consecutive adults (IDEAL Stage 2a), it achieved Hayhurst Grade 1 placement in 10 of 11 against 22 of 213 historically (p = 9 x 10^-9), median entry and angular deviations 2.5 mm and 5.9 degrees, 1.4 cm more intraventricular catheter than Keen's point, and no intraoperative complication. The technique was unchanged; the gain came from choosing entry and depth per patient. Whether it lowers revision is the next stage's hypothesis.

Related

  1. An Engineering Explanation of Human Vertical Reaching: Optimal Trajectory Planning of Asymmetric Velocity Profiles in the Vertical Plane via a Softplus-Based Generalized Dynamic Jerk Cost Function.
    M. B. Kabbani, A. Marouf
    bioRxivPreprintAll rights reservedFull textNeurosciencebioRxiv
  2. The Principal Component Life Trajectory (PCLT): Mapping Sex-Specific Physiological Change Across the Human Lifespan
    L. Royall, J. J. Baechle, A. Stankovic
    bioRxivPreprintCC BY-NCFull textSystems & synthetic biologybioRxiv
  3. Feasibility and acceptability of a randomized controlled trial of a patient-centred transition program for stroke survivors and their caregivers—P-NAVISTROKE study
    Marion Delvallée, Apolline Blazer, Mathilde Marchal +5
    Disability and RehabilitationPeer-reviewedLicence not statedGeneral biologyEpidemiology & public healthHAL
  4. Task-specific preferences guide forward planning in sequential decision-making
    A. Lepauvre, F. Ott, S. J. Kiebel
    bioRxivPreprintCC BYFull textNeurosciencebioRxiv
  5. Stereotactic guidance for ventricular catheter placement in ventriculoperitoneal shunt surgery: a state-of-the-art review on technical rationale, clinical outcomes, and future directions.
    Erich Talamoni Fonoff, Igor Baroni Cardoso, Alexandre Maria Santos
    Frontiers in neurologyPeer-reviewedCC BYFull textNeuroscienceEurope PMCCrossref
BibTeX
@misc{chongsrid2026feasibility,
  title = {{Feasibility of a Patient-Specific Digital Twin for Ventriculoperitoneal Shunt Trajectory Planning}},
  author = {Kritsanavis Chongsrid and Vich Yindeedej and Supaporn Konmun and Xulei Yang and Si Yong Yeo},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.20074},
  eprint = {2610.20074},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.20074},
}
RIS
TY  - UNPB
TI  - Feasibility of a Patient-Specific Digital Twin for Ventriculoperitoneal Shunt Trajectory Planning
AU  - Kritsanavis Chongsrid
AU  - Vich Yindeedej
AU  - Supaporn Konmun
AU  - Xulei Yang
AU  - Si Yong Yeo
PY  - 2026
DA  - 2026/10/14
PB  - arXiv
DO  - 10.48550/arxiv.2610.20074
UR  - https://arxiv.org/abs/2610.20074
AB  - Catheter obstruction is the commonest cause of shunt failure; freehand insertion at Keen's point leaves the tip free in cerebrospinal fluid in only one case in ten. We built a digital twin that reconstructs skull, scalp, ear and ventricles from preoperative CT by deterministic geometry, searches every entry around Keen's point for the perpendicular trajectory with the longest intraventricular length under safety constraints, and returns the plan as two ruler measurements from the ear and two depths. Executed freehand in 11 consecutive adults (IDEAL Stage 2a), it achieved Hayhurst Grade 1 placement in 10 of 11 against 22 of 213 historically (p = 9 x 10^-9), median entry and angular deviations 2.5 mm and 5.9 degrees, 1.4 cm more intraventricular catheter than Keen's point, and no intraoperative complication. The technique was unchanged; the gain came from choosing entry and depth per patient. Whether it lowers revision is the next stage's hypothesis.
ER  -